Engineering a sustainable future for point-of-care diagnostics and single-use microfluidic devices. Issue 17 (28th July 2022)
- Record Type:
- Journal Article
- Title:
- Engineering a sustainable future for point-of-care diagnostics and single-use microfluidic devices. Issue 17 (28th July 2022)
- Main Title:
- Engineering a sustainable future for point-of-care diagnostics and single-use microfluidic devices
- Authors:
- Ongaro, Alfredo Edoardo
Ndlovu, Zibusiso
Sollier, Elodie
Otieno, Collins
Ondoa, Pascale
Street, Alice
Kersaudy-Kerhoas, Maïwenn - Abstract:
- Abstract : Single-use, disposable, point-of-care diagnostic devices carry great promise for global health, but present some challenges in terms of environmental sustainability. This perspective covers solutions to embed sustainability at the R&D and product development stages. Abstract : Single-use, disposable, point-of-care diagnostic devices carry great promise for global health, including meeting urgent needs for testing and diagnosis in places with limited laboratory facilities. Unfortunately, the production and disposal of single-use devices, whether in lateral flow assay, cartridges, cassettes, or lab-on-chip microfluidic format, also poses significant challenges for environmental and human health. Point-of-care devices are commonly manufactured from unsustainable polymeric materials derived from fossil sources. Their disposal often necessitates incineration to reduce infection risk, thereby creating additional release of CO2 . Many devices also contain toxic chemicals, such as cyanide derivatives, that are damaging to environmental and human health if not disposed of safely. Yet, in the absence of government regulatory frameworks, safe and sustainable waste management for these novel medical devices is often left unaddressed. There is an urgent need to find novel solutions to avert environmental and human harm from these devices, especially in low- and middle-income countries where waste management infrastructure is often weak and where the use of point-of-care testsAbstract : Single-use, disposable, point-of-care diagnostic devices carry great promise for global health, but present some challenges in terms of environmental sustainability. This perspective covers solutions to embed sustainability at the R&D and product development stages. Abstract : Single-use, disposable, point-of-care diagnostic devices carry great promise for global health, including meeting urgent needs for testing and diagnosis in places with limited laboratory facilities. Unfortunately, the production and disposal of single-use devices, whether in lateral flow assay, cartridges, cassettes, or lab-on-chip microfluidic format, also poses significant challenges for environmental and human health. Point-of-care devices are commonly manufactured from unsustainable polymeric materials derived from fossil sources. Their disposal often necessitates incineration to reduce infection risk, thereby creating additional release of CO2 . Many devices also contain toxic chemicals, such as cyanide derivatives, that are damaging to environmental and human health if not disposed of safely. Yet, in the absence of government regulatory frameworks, safe and sustainable waste management for these novel medical devices is often left unaddressed. There is an urgent need to find novel solutions to avert environmental and human harm from these devices, especially in low- and middle-income countries where waste management infrastructure is often weak and where the use of point-of-care tests is projected to rise in coming years. We review here common materials used in the manufacture of single-use point-of-care diagnostic tests, examine the risks they pose to environmental and human health, and investigate replacement materials that can potentially reduce the impact of microfluidic devices on the production of harmful waste. We propose solutions available to point-of-care test developers to start embedding sustainability at an early stage in their design, and to reduce their non-renewable plastic consumption in research and product development. … (more)
- Is Part Of:
- Lab on a chip. Volume 22:Issue 17(2022)
- Journal:
- Lab on a chip
- Issue:
- Volume 22:Issue 17(2022)
- Issue Display:
- Volume 22, Issue 17 (2022)
- Year:
- 2022
- Volume:
- 22
- Issue:
- 17
- Issue Sort Value:
- 2022-0022-0017-0000
- Page Start:
- 3122
- Page End:
- 3137
- Publication Date:
- 2022-07-28
- Subjects:
- Miniature electronic equipment -- Periodicals
Combinatorial chemistry -- Periodicals
Biotechnology -- Periodicals
543.0813 - Journal URLs:
- http://pubs.rsc.org/en/journals/journalissues/lc#!recentarticles&adv ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/d2lc00380e ↗
- Languages:
- English
- ISSNs:
- 1473-0197
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5137.730000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 23418.xml