Assessment of agreement between EXTEM and NATEM thromboelastometry measurement assays in critically ill neonates. (22nd June 2022)
- Record Type:
- Journal Article
- Title:
- Assessment of agreement between EXTEM and NATEM thromboelastometry measurement assays in critically ill neonates. (22nd June 2022)
- Main Title:
- Assessment of agreement between EXTEM and NATEM thromboelastometry measurement assays in critically ill neonates
- Authors:
- Tsantes, Andreas G.
Konstantinidi, Aikaterini
Parastatidou, Stavroula
Ioakeimidis, Georgios
Tsante, Konstantina A.
Mantzios, Petros G.
Kriebardis, Anastasios G.
Gialeraki, Argyri
Houhoula, Dimitra
Iacovidou, Nicoletta
Piovani, Daniele
Bonovas, Stefanos
Tsantes, Argirios E.
Sokou, Rozeta - Abstract:
- Abstract: Objectives: To investigate the agreement between the EXTEM and NATEM measurements. Methods: In this retrospective observational study, EXTEM and NATEM analyses were performed on blood samples from 162 ill neonates, providing 324 paired measurements. The agreement between EXTEM and NATEM measurements was evaluated by the nonparametric spearman's rank correlation to assess the correlation between the paired measurements, by the Bland–Altman analysis for the graphical presentation of the agreement, and by the Deming regression model to assess the significance of the agreement. The agreement between the two methods for the detection of bleeding events was determined by kappa statistic. Results: Strong correlations were found between EXTEM and NATEM measurements for A10, MCF. The Bland–Altman plots showed good agreement for A10, MCF, LI60, and alpha angle parameters, while CT showed a nearly linear slope indicating that bias increased with the mean. The highest agreement for bleeding events was found for the A10 parameter ( κ = 0.70, p < .001), while the lowest for the CT parameter ( κ = 0.36, p = .94). Conclusions: NATEM parameters that reflect clot firmness and fibrinolytic activity are strongly correlated with the corresponding EXTEM measurements with a good agreement between them, indicating that these two methods could be used interchangeably.
- Is Part Of:
- European journal of haematology. Volume 109:Number 4(2022)
- Journal:
- European journal of haematology
- Issue:
- Volume 109:Number 4(2022)
- Issue Display:
- Volume 109, Issue 4 (2022)
- Year:
- 2022
- Volume:
- 109
- Issue:
- 4
- Issue Sort Value:
- 2022-0109-0004-0000
- Page Start:
- 327
- Page End:
- 335
- Publication Date:
- 2022-06-22
- Subjects:
- critically ill neonates -- EXTEM -- NATEM -- method comparison -- rotational thromboelastometry
Hematology -- Periodicals
Blood -- Diseases -- Periodicals
Blood -- Periodicals
616.15005 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1600-0609 ↗
http://www.blackwell-synergy.com/member/institutions/issuelist.asp?journal=ejh ↗
http://onlinelibrary.wiley.com/ ↗
http://firstsearch.oclc.org ↗ - DOI:
- 10.1111/ejh.13812 ↗
- Languages:
- English
- ISSNs:
- 0902-4441
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.729700
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 23394.xml