Digital Polymerase Chain Reaction for Assessment of Mutant Mitochondrial Carry-over after Nuclear Transfer for In Vitro Fertilization. (5th April 2021)
- Record Type:
- Journal Article
- Title:
- Digital Polymerase Chain Reaction for Assessment of Mutant Mitochondrial Carry-over after Nuclear Transfer for In Vitro Fertilization. (5th April 2021)
- Main Title:
- Digital Polymerase Chain Reaction for Assessment of Mutant Mitochondrial Carry-over after Nuclear Transfer for In Vitro Fertilization
- Authors:
- Tytgat, Olivier
Tang, Mao-Xing
van Snippenberg, Willem
Boel, Annekatrien
Guggilla, Ramesh Reddy
Gansemans, Yannick
Van Herp, Michiel
Symoens, Sofie
Trypsteen, Wim
Deforce, Dieter
Heindryckx, Björn
Coucke, Paul
De Spiegelaere, Ward
Van Nieuwerburgh, Filip - Abstract:
- Abstract: Background: The quantification of mitochondrial DNA heteroplasmy for the diagnosis of mitochondrial disease or after mitochondrial donation, is performed mainly using next-generation sequencing strategies (NGS). Digital PCR (dPCR) has the potential to offer an accurate alternative for mutation load quantification. Methods: We assessed the mutation load of 23 low-input human samples at the m.11778 locus, which is associated with Leber's hereditary optic neuropathy (LHON) using 2 droplet digital PCR platforms (Stilla Naica and Bio-Rad QX200) and the standard NGS strategy. Assay validation was performed by analyzing a titration series with mutation loads ranging from 50% to 0.01%. Results: A good concordance in mutation rates was observed between both dPCR techniques and NGS. dPCR established a distinctly lower level of background noise compared to NGS. Minor alleles with mutation loads lower than 1% could still be detected, with standard deviations of the technical replicates varying between 0.07% and 0.44% mutation load. Although no significant systematic bias was observed when comparing dPCR and NGS, a minor proportional bias was detected. A slight overestimation of the minor allele was observed for the NGS data, most probably due to amplification and sequencing errors in the NGS workflow. Conclusion: dPCR has proven to be an accurate tool for the quantification of mitochondrial heteroplasmy, even for samples harboring a low mutation load (<1%). In addition, thisAbstract: Background: The quantification of mitochondrial DNA heteroplasmy for the diagnosis of mitochondrial disease or after mitochondrial donation, is performed mainly using next-generation sequencing strategies (NGS). Digital PCR (dPCR) has the potential to offer an accurate alternative for mutation load quantification. Methods: We assessed the mutation load of 23 low-input human samples at the m.11778 locus, which is associated with Leber's hereditary optic neuropathy (LHON) using 2 droplet digital PCR platforms (Stilla Naica and Bio-Rad QX200) and the standard NGS strategy. Assay validation was performed by analyzing a titration series with mutation loads ranging from 50% to 0.01%. Results: A good concordance in mutation rates was observed between both dPCR techniques and NGS. dPCR established a distinctly lower level of background noise compared to NGS. Minor alleles with mutation loads lower than 1% could still be detected, with standard deviations of the technical replicates varying between 0.07% and 0.44% mutation load. Although no significant systematic bias was observed when comparing dPCR and NGS, a minor proportional bias was detected. A slight overestimation of the minor allele was observed for the NGS data, most probably due to amplification and sequencing errors in the NGS workflow. Conclusion: dPCR has proven to be an accurate tool for the quantification of mitochondrial heteroplasmy, even for samples harboring a low mutation load (<1%). In addition, this alternative technique holds multiple benefits compared to NGS (e.g., less hands-on time, more straightforward data-analysis, and a lower up-front capital investment). … (more)
- Is Part Of:
- Clinical chemistry. Volume 67:Number 7(2021)
- Journal:
- Clinical chemistry
- Issue:
- Volume 67:Number 7(2021)
- Issue Display:
- Volume 67, Issue 7 (2021)
- Year:
- 2021
- Volume:
- 67
- Issue:
- 7
- Issue Sort Value:
- 2021-0067-0007-0000
- Page Start:
- 968
- Page End:
- 976
- Publication Date:
- 2021-04-05
- Subjects:
- Clinical chemistry -- Periodicals
Pharmaceutical chemistry -- Periodicals
Biochemistry -- Periodicals
Biochimie -- Périodiques
Diagnostics biologiques -- Périodiques
Biochemistry
Clinical chemistry
Pharmaceutical chemistry
Biochemistry
Laboratory Techniques and Procedures
Klinische chemie
Periodicals
616.075605 - Journal URLs:
- http://www.oxfordjournals.org/ ↗
https://academic.oup.com/clinchem ↗
http://catalog.hathitrust.org/api/volumes/oclc/1554929.html ↗
http://www.clinchem.org/ ↗ - DOI:
- 10.1093/clinchem/hvab021 ↗
- Languages:
- English
- ISSNs:
- 0009-9147
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23413.xml