Quantification of Amyloid-β in Plasma by Simple and Highly Sensitive Immunoaffinity Enrichment and LC-MS/MS Assay. (19th January 2021)
- Record Type:
- Journal Article
- Title:
- Quantification of Amyloid-β in Plasma by Simple and Highly Sensitive Immunoaffinity Enrichment and LC-MS/MS Assay. (19th January 2021)
- Main Title:
- Quantification of Amyloid-β in Plasma by Simple and Highly Sensitive Immunoaffinity Enrichment and LC-MS/MS Assay
- Authors:
- Iino, Takuya
Watanabe, Shunsuke
Yamashita, Kazuto
Tamada, Eiya
Hasegawa, Takehiro
Irino, Yasuhiro
Iwanaga, Shigeki
Harada, Amane
Noda, Kenta
Suto, Kouzou
Yoshida, Tomokazu - Abstract:
- Abstract: Background: Numerous immunoassays have been developed to quantify amyloid β1-40 (Aβ40 ) and amyloid β1-42 (Aβ42 ). Nevertheless, given the low concentration of Aβ and the high levels of interfering factors in plasma, quantification of plasma Aβ is still challenging. To overcome the problems related to the specificity of Aβ immunoassays, this study aimed to develop an immunoaffinity enrichment and LC-MS/MS (IA-MS) assay. Methods: We developed an IA-MS assay using antibody-labeled magnetic beads for purification and LC-MS/MS for Aβ quantification. To avoid the loss of Aβ due to aggregation in acidic buffer, we used alkaline elution buffer for immunoaffinity enrichment. The concentrations of the Aβs in plasma samples were measured, and the correlation between the plasma and cerebrospinal fluid (CSF) Aβ42 /Aβ40 ratio was also evaluated. Results: The intensities of the Aβ mass peaks were significantly higher with the alkaline elution buffer than with the acidic elution buffer (Aβ40 : 3.6-fold, Aβ42: 5.4-fold). This assay exhibited high reproducibility (intra-assay and inter-assay precision, %CV <15), and the working ranges of Aβ40 and Aβ42 were determined to be 21.7 to 692.8 pg/mL and 5.6 to 180.6 pg/mL, respectively. The concentrations of Aβ40 and Aβ42 in plasma were measured by IA-MS, and the plasma Aβ42 /Aβ40 ratio was correlated with the CSF Aβ42 /Aβ40 ratio ( rs = 0.439, P < 0.01). Conclusions: The IA-MS assay has sufficient analytic performance for measuringAbstract: Background: Numerous immunoassays have been developed to quantify amyloid β1-40 (Aβ40 ) and amyloid β1-42 (Aβ42 ). Nevertheless, given the low concentration of Aβ and the high levels of interfering factors in plasma, quantification of plasma Aβ is still challenging. To overcome the problems related to the specificity of Aβ immunoassays, this study aimed to develop an immunoaffinity enrichment and LC-MS/MS (IA-MS) assay. Methods: We developed an IA-MS assay using antibody-labeled magnetic beads for purification and LC-MS/MS for Aβ quantification. To avoid the loss of Aβ due to aggregation in acidic buffer, we used alkaline elution buffer for immunoaffinity enrichment. The concentrations of the Aβs in plasma samples were measured, and the correlation between the plasma and cerebrospinal fluid (CSF) Aβ42 /Aβ40 ratio was also evaluated. Results: The intensities of the Aβ mass peaks were significantly higher with the alkaline elution buffer than with the acidic elution buffer (Aβ40 : 3.6-fold, Aβ42: 5.4-fold). This assay exhibited high reproducibility (intra-assay and inter-assay precision, %CV <15), and the working ranges of Aβ40 and Aβ42 were determined to be 21.7 to 692.8 pg/mL and 5.6 to 180.6 pg/mL, respectively. The concentrations of Aβ40 and Aβ42 in plasma were measured by IA-MS, and the plasma Aβ42 /Aβ40 ratio was correlated with the CSF Aβ42 /Aβ40 ratio ( rs = 0.439, P < 0.01). Conclusions: The IA-MS assay has sufficient analytic performance for measuring endogenous Aβ40 and Aβ42 in plasma. This assay can lead to new lines of clinical discovery related to amyloid pathology. … (more)
- Is Part Of:
- Journal of applied laboratory medicine. Volume 6:Number 4(2021)
- Journal:
- Journal of applied laboratory medicine
- Issue:
- Volume 6:Number 4(2021)
- Issue Display:
- Volume 6, Issue 4 (2021)
- Year:
- 2021
- Volume:
- 6
- Issue:
- 4
- Issue Sort Value:
- 2021-0006-0004-0000
- Page Start:
- 834
- Page End:
- 845
- Publication Date:
- 2021-01-19
- Subjects:
- Clinical chemistry -- Periodicals
Diagnosis, Laboratory -- Periodicals
616.0756 - Journal URLs:
- http://www.oxfordjournals.org/ ↗
https://academic.oup.com/jalm ↗ - DOI:
- 10.1093/jalm/jfaa225 ↗