Probability of detection applied to X-ray inspection using numerical simulations. Issue 5 (3rd September 2022)
- Record Type:
- Journal Article
- Title:
- Probability of detection applied to X-ray inspection using numerical simulations. Issue 5 (3rd September 2022)
- Main Title:
- Probability of detection applied to X-ray inspection using numerical simulations
- Authors:
- Yosifov, M.
Reiter, M.
Heupl, S.
Gusenbauer, C.
Fröhler, B.
Fernández- Gutiérrez, R.
De Beenhouwer, J.
Sijbers, J.
Kastner, J.
Heinzl, C. - Abstract:
- ABSTRACT: In this work, we apply and adapt established probability of detection (POD) methods on the in-line inspection of aluminium cylinder heads using X-ray computed tomography (XCT). We propose to use the XCT simulation tool SimCT to simulate virtual X-ray radiographs from the specimen including artificial defects, which avoids the manufacturing of specimens with calibrated defects of known type (e.g. pores, inclusions, cracks) and characteristics (e.g. size, shape, location). To quantify the POD, these virtual images are analysed using ZEISS automated defect detection (ZADD) to determine defects automatically. ZADD is a deep learning application for anomaly defect detection, classification and segmentation. To create respective POD curves, we apply a hit/miss approach. We demonstrate our method on artificial defects of different sizes, location and material types. Eight representative defects are discussed in detail together with the generated POD curves as well as their characteristics. We finally discuss the advantages of numerical simulations with respect to the probability of detection in order to quantify and improve detection limits.
- Is Part Of:
- Nondestructive testing and evaluation. Volume 37:Issue 5(2022)
- Journal:
- Nondestructive testing and evaluation
- Issue:
- Volume 37:Issue 5(2022)
- Issue Display:
- Volume 37, Issue 5 (2022)
- Year:
- 2022
- Volume:
- 37
- Issue:
- 5
- Issue Sort Value:
- 2022-0037-0005-0000
- Page Start:
- 536
- Page End:
- 551
- Publication Date:
- 2022-09-03
- Subjects:
- Probability of detection -- X-ray computed tomography -- numerical simulation -- hit/miss approach
Non-destructive testing -- Periodicals
620.112705 - Journal URLs:
- http://journalsonline.tandf.co.uk/app/home/journal.asp?wasp=23tyjmuxtj5xnmgunm13&referrer=parent&backto=searchpublicationsresults, 1, 1;homemain, 1, 1; ↗
http://www.tandfonline.com/toc/gnte20/current ↗
http://www.tandfonline.com/ ↗ - DOI:
- 10.1080/10589759.2022.2071892 ↗
- Languages:
- English
- ISSNs:
- 1058-9759
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6117.044700
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 23398.xml