Evaluation of the Clinical Performance of 7 Serological Assays for SARS-CoV-2 for Use in Clinical Laboratories. (17th May 2021)
- Record Type:
- Journal Article
- Title:
- Evaluation of the Clinical Performance of 7 Serological Assays for SARS-CoV-2 for Use in Clinical Laboratories. (17th May 2021)
- Main Title:
- Evaluation of the Clinical Performance of 7 Serological Assays for SARS-CoV-2 for Use in Clinical Laboratories
- Authors:
- Plaga, Alexis
Wei, Ruhan
Olson, Elizabeth
Payto, Drew
Harrington, John
Nwe-Kissig, Pyik That
Strizzi, Michelle
Zilka, Sarah
Ko, Jennifer
Colón-Franco, Jessica M - Abstract:
- Abstract: Background: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) serological assays have emerged as a response to the global pandemic, warranting studies evaluating their clinical performance. This study investigated 7 commercially available SARS-CoV-2 serological assays in samples from noninfected individuals and hospitalized patients. Methods: SARS-CoV-2 qualitative serological assays by Abbott (IgG), Beckman (IgG), DiaSorin (IgG), EUROIMMUN (IgG and IgA), Roche and Bio-Rad (Total) were evaluated using specimens collected pre-December 2019 (n = 393), from nucleic acid amplification testing (NAAT) negative patients (n = 40), and from 53 patients with COVID-19 by NAAT collected 3–21 days post-onset of symptoms (POS) (N = 83). Negative agreement (NA), positive agreement (PA), and positive and negative predictive values (PPV and NPV) at prevalences of 5% and 10% were calculated. Results: The overall %NA; 95% CI in the negative samples were: Roche 99.8%; 99.3–100.2, Beckman 99.8%; 98.7–100.0, Abbott and Bio-Rad 99.3%; 98.0–99.9, DiaSorin 98.4; 97.2–99.6, EUROIMMUN IgG 97.5%; 95.5–98.7, and EUROIMMUN IgA 79.7%; 75.9–83.5), accounting for positive/equivocal results as false positives. The %PA; 95% CI in samples collected 14+ days POS (n = 24) were: Bio-Rad 83.3%; 68.4–98.2, Abbott and Roche 79.2%; 62.9–95.4, EUROIMMUN IgA 70.8%; 52.6–89.0, Beckman 58.3%; 38.6–78.1, DiaSorin 54.2; 34.2–74.1, and EUROIMMUN IgG 50.0%; 30.0–70.0, accounting for negative/equivocalAbstract: Background: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) serological assays have emerged as a response to the global pandemic, warranting studies evaluating their clinical performance. This study investigated 7 commercially available SARS-CoV-2 serological assays in samples from noninfected individuals and hospitalized patients. Methods: SARS-CoV-2 qualitative serological assays by Abbott (IgG), Beckman (IgG), DiaSorin (IgG), EUROIMMUN (IgG and IgA), Roche and Bio-Rad (Total) were evaluated using specimens collected pre-December 2019 (n = 393), from nucleic acid amplification testing (NAAT) negative patients (n = 40), and from 53 patients with COVID-19 by NAAT collected 3–21 days post-onset of symptoms (POS) (N = 83). Negative agreement (NA), positive agreement (PA), and positive and negative predictive values (PPV and NPV) at prevalences of 5% and 10% were calculated. Results: The overall %NA; 95% CI in the negative samples were: Roche 99.8%; 99.3–100.2, Beckman 99.8%; 98.7–100.0, Abbott and Bio-Rad 99.3%; 98.0–99.9, DiaSorin 98.4; 97.2–99.6, EUROIMMUN IgG 97.5%; 95.5–98.7, and EUROIMMUN IgA 79.7%; 75.9–83.5), accounting for positive/equivocal results as false positives. The %PA; 95% CI in samples collected 14+ days POS (n = 24) were: Bio-Rad 83.3%; 68.4–98.2, Abbott and Roche 79.2%; 62.9–95.4, EUROIMMUN IgA 70.8%; 52.6–89.0, Beckman 58.3%; 38.6–78.1, DiaSorin 54.2; 34.2–74.1, and EUROIMMUN IgG 50.0%; 30.0–70.0, accounting for negative/equivocal results as false negatives. NPVs ranged from 97.4%–98.9% and 94.7%–97.7% for prevalences 5% and 10%, respectively. PPVs ranged from 15.5%–94.8% and 27.9%–97.4% for prevalences 5% and 10%, respectively. Conclusion: The Roche and Beckman assays resulted in fewer false positives, followed by the Bio-Rad and Abbott assays. While the Bio-Rad assay demonstrated higher antibody detection in COVID-19-positive patients, PA claims cannot be established with a high level of confidence in our sample population. … (more)
- Is Part Of:
- Journal of applied laboratory medicine. Volume 6:Number 4(2021)
- Journal:
- Journal of applied laboratory medicine
- Issue:
- Volume 6:Number 4(2021)
- Issue Display:
- Volume 6, Issue 4 (2021)
- Year:
- 2021
- Volume:
- 6
- Issue:
- 4
- Issue Sort Value:
- 2021-0006-0004-0000
- Page Start:
- 998
- Page End:
- 1004
- Publication Date:
- 2021-05-17
- Subjects:
- serology -- SARS-CoV-2 -- COVID-19 -- antibody
Clinical chemistry -- Periodicals
Diagnosis, Laboratory -- Periodicals
616.0756 - Journal URLs:
- http://www.oxfordjournals.org/ ↗
https://academic.oup.com/jalm ↗ - DOI:
- 10.1093/jalm/jfab038 ↗
- Languages:
- English
- ISSNs:
- 2576-9456
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23413.xml