Near-lossless compression of PET/CT images using singular value decomposition. Issue 10 (22nd August 2022)
- Record Type:
- Journal Article
- Title:
- Near-lossless compression of PET/CT images using singular value decomposition. Issue 10 (22nd August 2022)
- Main Title:
- Near-lossless compression of PET/CT images using singular value decomposition
- Authors:
- Chaudhary, Jagrati
Pandey, Anil Kumar
Sharma, Param D.
Jaleel, Jasim
Patel, Chetan
Bal, Chandra Sekhar
Kumar, Rakesh - Abstract:
- Abstract : Aims and objectives: The aim of the study is to compare the single matrix approach and slice-by-slice approach for computing singular value decomposition (SVD) to achieve near-lossless compression of PET/CT images. Materials and methods: The parameters used for comparison were SVD computation time, percentage compression and percentage difference between ROI counts on compressed and original images. SVD of 49 F-18-FDG PET/CT studies (33 370 PET/CT images) was computed using both approaches. The smaller singular values contributing insignificant information to the image were truncated, and then, the compressed image was reconstructed. A mask (101 × 101pixels) was used to extract the ROI counts from compressed and original images. Two nuclear medicine physicians compared compressed images with their corresponding original images for loss of clinical details and the presence of generated artifacts. Structural Similarity Index Measure, blur, brightness, contrast per pixel and global contrast factor were used for objective assessment of image quality. Wilcoxon test was applied to find a statistically significant difference between the parameters used for comparison at alpha = 0.05. Results: Nuclear medicine physicians found compressed image identical to the corresponding original image. The values of comparation parameters were significantly larger for the single matrix approach in comparison with the slice-by-slice approach. The maximum percentage error between theAbstract : Aims and objectives: The aim of the study is to compare the single matrix approach and slice-by-slice approach for computing singular value decomposition (SVD) to achieve near-lossless compression of PET/CT images. Materials and methods: The parameters used for comparison were SVD computation time, percentage compression and percentage difference between ROI counts on compressed and original images. SVD of 49 F-18-FDG PET/CT studies (33 370 PET/CT images) was computed using both approaches. The smaller singular values contributing insignificant information to the image were truncated, and then, the compressed image was reconstructed. A mask (101 × 101pixels) was used to extract the ROI counts from compressed and original images. Two nuclear medicine physicians compared compressed images with their corresponding original images for loss of clinical details and the presence of generated artifacts. Structural Similarity Index Measure, blur, brightness, contrast per pixel and global contrast factor were used for objective assessment of image quality. Wilcoxon test was applied to find a statistically significant difference between the parameters used for comparison at alpha = 0.05. Results: Nuclear medicine physicians found compressed image identical to the corresponding original image. The values of comparation parameters were significantly larger for the single matrix approach in comparison with the slice-by-slice approach. The maximum percentage error between the compressed image and original image was less than 5%. Conclusions: Up to 64 % and 44% near-lossless compression of PET and CT images were achieved, respectively using the slice-by-slice approach, and up to 58 and 53% near-lossless compression of PET and CT images were achieved respectively using the single matrix approach. … (more)
- Is Part Of:
- Nuclear medicine communications. Volume 43:Issue 10(2022)
- Journal:
- Nuclear medicine communications
- Issue:
- Volume 43:Issue 10(2022)
- Issue Display:
- Volume 43, Issue 10 (2022)
- Year:
- 2022
- Volume:
- 43
- Issue:
- 10
- Issue Sort Value:
- 2022-0043-0010-0000
- Page Start:
- 1099
- Page End:
- 1106
- Publication Date:
- 2022-08-22
- Subjects:
- image compression -- PET/CT study -- singular value decomposition
Nuclear medicine -- Periodicals
616.07575 - Journal URLs:
- http://journals.lww.com/nuclearmedicinecomm/pages/default.aspx ↗
http://journals.lww.com/pages/default.aspx ↗
http://www.lww.com/Product/0143-3636 ↗ - DOI:
- 10.1097/MNM.0000000000001603 ↗
- Languages:
- English
- ISSNs:
- 0143-3636
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6180.923000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 23419.xml