A three‐dimensional free‐breathing sequence for simultaneous myocardial T1 and T2 mapping. Issue 2 (4th November 2018)
- Record Type:
- Journal Article
- Title:
- A three‐dimensional free‐breathing sequence for simultaneous myocardial T1 and T2 mapping. Issue 2 (4th November 2018)
- Main Title:
- A three‐dimensional free‐breathing sequence for simultaneous myocardial T1 and T2 mapping
- Authors:
- Guo, Rui
Chen, Zhensen
Herzka, Daniel A.
Luo, Jianwen
Ding, Haiyan - Abstract:
- Abstract : Purpose: The aim of this study was to develop, test and validate a 3D free‐breathing technique for simultaneous measurement of native myocardial T1 and T2 . Methods: The proposed 3D technique acquires five fat‐suppressed electrocardiogram‐triggered respiratory navigator‐gated spoiled gradient echo volumes in an interleaved manner. Four volumes are prepared using a combination of nonselective saturation and T2 preparation. One volume is acquired with fully recovered longitudinal magnetization for accuracy during parametric fitting. Performance of the technique was validated through numerical simulations, phantom experiments and in vivo experiments in 15 healthy human subjects. Results: Simulations and phantom experiments show that the measured T1 and T2 are largely insensitive to heart rate. In vivo whole‐heart maps with a voxel size of 1.5 × 1.5 × 16 mm 3 were acquired without parallel imaging within ~ 8 min including respiratory gating efficiency. The in vivo parametric maps were homogeneous (coefficients of variation of left ventricle myocardium were 6.0% ± 0.8% and 10.2% ± 3.4% for T1 and T2 maps, respectively), with an average T1 value of 1470 ± 59.2 ms and T2 value of 41.6 ± 1.8 ms Conclusions: The proposed 3D technique allows for measurement of whole‐heart T1 and T2 with preserved accuracy and precision in a single scan.
- Is Part Of:
- Magnetic resonance in medicine. Volume 81:Issue 2(2019)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 81:Issue 2(2019)
- Issue Display:
- Volume 81, Issue 2 (2019)
- Year:
- 2019
- Volume:
- 81
- Issue:
- 2
- Issue Sort Value:
- 2019-0081-0002-0000
- Page Start:
- 1031
- Page End:
- 1043
- Publication Date:
- 2018-11-04
- Subjects:
- free‐breathing -- myocardial T1 mapping -- myocardial T2 mapping -- saturation -- T2 preparation -- three‐dimensional
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.27466 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23388.xml