Dose Reduction and Image Quality in Photon-counting Detector High-resolution Computed Tomography of the Chest: Routine Clinical Data. Issue 5 (14th September 2022)
- Record Type:
- Journal Article
- Title:
- Dose Reduction and Image Quality in Photon-counting Detector High-resolution Computed Tomography of the Chest: Routine Clinical Data. Issue 5 (14th September 2022)
- Main Title:
- Dose Reduction and Image Quality in Photon-counting Detector High-resolution Computed Tomography of the Chest
- Authors:
- Graafen, Dirk
Emrich, Tilman
Halfmann, Moritz C.
Mildenberger, Peter
Düber, Christoph
Yang, Yang
Othman, Ahmed E.
O' Doherty, Jim
Müller, Lukas
Kloeckner, Roman - Abstract:
- Abstract : Purpose: Photon-counting detector computed tomography (PCD-CT) has the potential to significantly improve CT imaging in many ways including, but not limited to, low-dose high-resolution CT (HRCT) of the lung. The aim of this study was to perform an intrapatient comparison of the radiation dose and image quality of PCD-CT compared with conventional energy-integrating detector CT (EID-CT). Methods: A total of 32 consecutive patients with available PCD-CT and EID-CT HRCT scans were included in the final analysis. The CT dose index (CTDIvol ) was extracted from patient dose reports. Qualitative image analysis comprised the lung parenchyma and mediastinal structures and was assessed by 3 readers using a 5-point Likert scale. Quantitative image analysis included assessment of noise and signal-to-noise ratio in the lung parenchyma, trachea, aorta, muscle, and background. Results: The mean CTDIvol was 2.0 times higher in the conventional EID-CT scans (1.8±0.5 mGy) compared with PCD-CT (0.9±0.5 mGy, P <0.001). The overall image quality was rated significantly better by all 3 raters ( P <0.001) in the PCD-CT relative to the EID-CT. Quantitative analysis showed no significant differences in noise and signal-to-noise ratio in the lung parenchyma between PCD-CT and EID-CT. Conclusion: Compared with conventional EID-CT scans, PCD-CT demonstrated similar or better objective and subjective image quality at significantly reduced dose levels in an intrapatient comparison. TheseAbstract : Purpose: Photon-counting detector computed tomography (PCD-CT) has the potential to significantly improve CT imaging in many ways including, but not limited to, low-dose high-resolution CT (HRCT) of the lung. The aim of this study was to perform an intrapatient comparison of the radiation dose and image quality of PCD-CT compared with conventional energy-integrating detector CT (EID-CT). Methods: A total of 32 consecutive patients with available PCD-CT and EID-CT HRCT scans were included in the final analysis. The CT dose index (CTDIvol ) was extracted from patient dose reports. Qualitative image analysis comprised the lung parenchyma and mediastinal structures and was assessed by 3 readers using a 5-point Likert scale. Quantitative image analysis included assessment of noise and signal-to-noise ratio in the lung parenchyma, trachea, aorta, muscle, and background. Results: The mean CTDIvol was 2.0 times higher in the conventional EID-CT scans (1.8±0.5 mGy) compared with PCD-CT (0.9±0.5 mGy, P <0.001). The overall image quality was rated significantly better by all 3 raters ( P <0.001) in the PCD-CT relative to the EID-CT. Quantitative analysis showed no significant differences in noise and signal-to-noise ratio in the lung parenchyma between PCD-CT and EID-CT. Conclusion: Compared with conventional EID-CT scans, PCD-CT demonstrated similar or better objective and subjective image quality at significantly reduced dose levels in an intrapatient comparison. These results and their effect on clinical decision-making should be further investigated in prospective studies. … (more)
- Is Part Of:
- Journal of thoracic imaging. Volume 37:Issue 5(2022)
- Journal:
- Journal of thoracic imaging
- Issue:
- Volume 37:Issue 5(2022)
- Issue Display:
- Volume 37, Issue 5 (2022)
- Year:
- 2022
- Volume:
- 37
- Issue:
- 5
- Issue Sort Value:
- 2022-0037-0005-0000
- Page Start:
- 315
- Page End:
- 322
- Publication Date:
- 2022-09-14
- Subjects:
- high-resolution computed tomography -- photon-counting detector -- tin filtration -- dose reduction
Chest -- Radiography -- Periodicals
Chest -- Diseases -- Diagnosis -- Periodicals
617.540757 - Journal URLs:
- http://journals.lww.com/thoracicimaging/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/RTI.0000000000000661 ↗
- Languages:
- English
- ISSNs:
- 0883-5993
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5069.120000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 23379.xml