C-arm cone-beam computed tomography-guided minimally invasive open excision of an osteoid osteoma undetectable on fluoroscopy: A case report. (2019)
- Record Type:
- Journal Article
- Title:
- C-arm cone-beam computed tomography-guided minimally invasive open excision of an osteoid osteoma undetectable on fluoroscopy: A case report. (2019)
- Main Title:
- C-arm cone-beam computed tomography-guided minimally invasive open excision of an osteoid osteoma undetectable on fluoroscopy: A case report
- Authors:
- Higuchi, Takashi
Yamamoto, Norio
Hayashi, Katsuhiro
Takeuchi, Akihiko
Abe, Kensaku
Taniguchi, Yuta
Araki, Yoshihiro
Tsuchiya, Hiroyuki - Abstract:
- Highlights: A robotic C-arm cone-beam computed tomography (CBCT) system provides a clear intraoperative visualization of the osteoid osteoma. C-arm CBCT allowed precise access to the tumor, accurate tumor resection, and minimal sacrifice of the normal bone in osteoid osteoma surgery. Repurpose use of the dilator, retractor, and wider trephine tips achieved more conservative results with a smaller skin incision. Abstract: Introduction: The small size of a nidus and the extensive sclerosis around it often make it difficult to identify tumors from the surrounding normal bone by fluoroscopy, and a large amount of bone resection might be required to secure complete removal during osteoid osteoma surgery. In this report, we present the first case of radiographically invisible osteoid osteoma that was successfully resected under a robotic C-arm cone-beam computed tomography (CBCT) imaging system. Presentation of case: A 14-year-old boy presented with persistent pain around the left knee joint was diagnosed with osteoid osteoma of the left distal femur. Since the tumor was not detectable by intraoperative fluoroscopy, a CBCT system was used for guidance during an open tumor resection. For a less invasive surgery, we repurposed the dilator and retractor of the microendoscopic discectomy (MED) system and resected the tumor using the wider trephine tips for bone biopsy. At the final follow-up one year later, the function of the afflicted limb was normal with no complaint of anyHighlights: A robotic C-arm cone-beam computed tomography (CBCT) system provides a clear intraoperative visualization of the osteoid osteoma. C-arm CBCT allowed precise access to the tumor, accurate tumor resection, and minimal sacrifice of the normal bone in osteoid osteoma surgery. Repurpose use of the dilator, retractor, and wider trephine tips achieved more conservative results with a smaller skin incision. Abstract: Introduction: The small size of a nidus and the extensive sclerosis around it often make it difficult to identify tumors from the surrounding normal bone by fluoroscopy, and a large amount of bone resection might be required to secure complete removal during osteoid osteoma surgery. In this report, we present the first case of radiographically invisible osteoid osteoma that was successfully resected under a robotic C-arm cone-beam computed tomography (CBCT) imaging system. Presentation of case: A 14-year-old boy presented with persistent pain around the left knee joint was diagnosed with osteoid osteoma of the left distal femur. Since the tumor was not detectable by intraoperative fluoroscopy, a CBCT system was used for guidance during an open tumor resection. For a less invasive surgery, we repurposed the dilator and retractor of the microendoscopic discectomy (MED) system and resected the tumor using the wider trephine tips for bone biopsy. At the final follow-up one year later, the function of the afflicted limb was normal with no complaint of any symptoms. Plain radiograph at the final follow-up showed new bone formation completely filling the bone defect, without local recurrence. Discussion: CBCT allowed for clear intraoperative visualization of the osteoid osteoma, thereby promising a secure resection and less invasive osteoid osteoma treatment. Furthermore, the repurposed use of the dilator and retractor of the MED system as well as the wider trephine tips for bone biopsy made the procedure less invasive. Conclusion: CBCT-guided minimally invasive open excision surgery could be a useful option for the management of radiographically invisible osteoid osteoma. … (more)
- Is Part Of:
- International journal of surgery case reports. Volume 61(2019)
- Journal:
- International journal of surgery case reports
- Issue:
- Volume 61(2019)
- Issue Display:
- Volume 61, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 61
- Issue:
- 2019
- Issue Sort Value:
- 2019-0061-2019-0000
- Page Start:
- 14
- Page End:
- 19
- Publication Date:
- 2019
- Subjects:
- Osteoid osteoma -- A robotic C-arm cone-beam computed tomography -- Minimally invasive surgery -- Case report
Surgery -- Periodicals
Surgical Procedures, Operative -- Periodicals
Surgery
Electronic journals
Periodicals
617.005 - Journal URLs:
- http://www.sciencedirect.com/science/journal/22102612 ↗
http://www.ncbi.nlm.nih.gov/pmc/journals/1424/ ↗
http://www.casereports.com/ ↗
http://www.clinicalkey.com/dura/browse/journalIssue/22102612 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ijscr.2019.06.062 ↗
- Languages:
- English
- ISSNs:
- 2210-2612
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23383.xml