In vivo measurement of distance between scapular neck and polyethylene insert during active external rotation in shoulders with Grammont type reverse prosthesis. (April 2021)
- Record Type:
- Journal Article
- Title:
- In vivo measurement of distance between scapular neck and polyethylene insert during active external rotation in shoulders with Grammont type reverse prosthesis. (April 2021)
- Main Title:
- In vivo measurement of distance between scapular neck and polyethylene insert during active external rotation in shoulders with Grammont type reverse prosthesis
- Authors:
- Matsuki, Keisuke
Matsuki, Kei O.
Sugaya, Hiroyuki
Takahashi, Norimasa
Tokai, Morihito
Ueda, Yusuke
Hoshika, Shota
Hamada, Hiroshige
Banks, Scott A. - Abstract:
- Abstract: Background: Scapular notching is a frequently observed complication after reverse shoulder arthroplasty. Impingement of the humeral plastic insert against the scapular neck is believed to be the cause of notching. There have been no in vivo studies that analyzed the positional relationship between the scapular neck and humeral insert. The purpose of this study was to measure the distance between the scapular neck and insert in shoulders with Grammont-type prostheses during active external rotation at the side. Methods: Eighteen shoulders with Grammont-type prostheses were enrolled in this study. There were 13 males and 5 females, and the mean age at surgery was 74 years (range, 63–91). Fluoroscopic images were recorded during active external rotation at the side from maximum internal to external rotation at an average of 14 months (range, 7–24) after surgery. Implant kinematics were determined with three-dimensional models of the implants and fluoroscopic images using model-image registration techniques. Based on the implant kinematics, the closest distance between the scapular neck and insert was computed at each 5° increment of glenohumeral internal/external rotation. Results: Mean glenohumeral abduction during rotation was 17°–22°. The mean distance between the neck and insert was approximately 1 mm throughout the activity. The separation distance tended to narrow with arm external rotation, but the change was not significant. Interpretation: The small distanceAbstract: Background: Scapular notching is a frequently observed complication after reverse shoulder arthroplasty. Impingement of the humeral plastic insert against the scapular neck is believed to be the cause of notching. There have been no in vivo studies that analyzed the positional relationship between the scapular neck and humeral insert. The purpose of this study was to measure the distance between the scapular neck and insert in shoulders with Grammont-type prostheses during active external rotation at the side. Methods: Eighteen shoulders with Grammont-type prostheses were enrolled in this study. There were 13 males and 5 females, and the mean age at surgery was 74 years (range, 63–91). Fluoroscopic images were recorded during active external rotation at the side from maximum internal to external rotation at an average of 14 months (range, 7–24) after surgery. Implant kinematics were determined with three-dimensional models of the implants and fluoroscopic images using model-image registration techniques. Based on the implant kinematics, the closest distance between the scapular neck and insert was computed at each 5° increment of glenohumeral internal/external rotation. Results: Mean glenohumeral abduction during rotation was 17°–22°. The mean distance between the neck and insert was approximately 1 mm throughout the activity. The separation distance tended to narrow with arm external rotation, but the change was not significant. Interpretation: The small distance between the scapular neck and insert in early post-operative reverse shoulder arthroplasty patients may be associated with the high incidence of scapular notching in Grammont-type prostheses. Highlights: We analyzed three-dimensional reverse shoulder kinematics during external rotation. We measured the distance between the scapular neck and polyethylene insert. The mean distance was approximately 1 mm throughout the activity. The distance was < 1 mm over the whole rotation in 61% of shoulders. … (more)
- Is Part Of:
- Clinical biomechanics. Volume 84(2021)
- Journal:
- Clinical biomechanics
- Issue:
- Volume 84(2021)
- Issue Display:
- Volume 84, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 84
- Issue:
- 2021
- Issue Sort Value:
- 2021-0084-2021-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-04
- Subjects:
- Shoulder -- Reverse shoulder arthroplasty -- Model-image registration techniques -- Inferior scapular impingement -- Scapular notching
Biomechanics -- Periodicals
Osteopathic medicine -- Periodicals
Biomechanics -- Periodicals
Osteopathic Medicine -- Periodicals
612.76 - Journal URLs:
- http://www.sciencedirect.com/science/journal/02680033 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.clinbiomech.2021.105341 ↗
- Languages:
- English
- ISSNs:
- 0268-0033
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.262800
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23392.xml