Uncertainties of calculated Cramér‐Rao lower bounds: implications for quantitative MRS. Issue 2 (11th September 2018)
- Record Type:
- Journal Article
- Title:
- Uncertainties of calculated Cramér‐Rao lower bounds: implications for quantitative MRS. Issue 2 (11th September 2018)
- Main Title:
- Uncertainties of calculated Cramér‐Rao lower bounds: implications for quantitative MRS
- Authors:
- Bonny, Jean‐Marie
Pagès, Guilhem - Abstract:
- Abstract : Purpose: To investigate the uncertainties on relative Cramér‐Rao lower bound (rCRB) estimates and demonstrate their biasing effects in MRS quantification. Theory and Methods: Simulations were performed to calculate the distribution of the computed rCRB (noted rCRB*) for several rCRB levels. One hundred thousand simulations per rCRB value were performed on simulated NMR signals containing either 1 signal (singlet) or 2 partially overlapping signals. False‐positive and false‐negative risks were compiled for different threshold levels. rCRB* distribution was experimentally checked on a deuterated water sample using a 9.4 Tesla vertical magnet. Results: Simulations showed that (1) rCRB* distribution is asymmetrical, with a right‐tailed distribution increasing the risk of accepting false‐positive data (i.e., accepting an rCRB* value whereas the true rCRB value is higher than the threshold level) and (2) distribution broadness increases with increasing rCRB level. Simulations with overlapped peaks lead to more inaccuracy in the rCRB estimation. Probabilities of false detection increase with increasing threshold level. Conclusion: Analyzing results thanks to a CRB (or rCRB) based on experimental measurements might lead to misinterpretations. To exploit the rCRB* as rejection criteria, a conservative threshold level of 20% is recommended in order to limit the probability of false alarms.
- Is Part Of:
- Magnetic resonance in medicine. Volume 81:Issue 2(2019)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 81:Issue 2(2019)
- Issue Display:
- Volume 81, Issue 2 (2019)
- Year:
- 2019
- Volume:
- 81
- Issue:
- 2
- Issue Sort Value:
- 2019-0081-0002-0000
- Page Start:
- 759
- Page End:
- 764
- Publication Date:
- 2018-09-11
- Subjects:
- false alarm -- false negative -- false positive -- threshold level
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.27415 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23371.xml