Combined imaging and shimming with the dynamic multi‐coil technique. Issue 2 (10th October 2018)
- Record Type:
- Journal Article
- Title:
- Combined imaging and shimming with the dynamic multi‐coil technique. Issue 2 (10th October 2018)
- Main Title:
- Combined imaging and shimming with the dynamic multi‐coil technique
- Authors:
- Umesh Rudrapatna, S.
Fluerenbrock, Fabian
Nixon, Terence W.
de Graaf, Robin A.
Juchem, Christoph - Abstract:
- Abstract : Purpose: Spatial encoding and shimming in MRI have traditionally been performed using dedicated coils that generate orthogonal spherical harmonic fields. The recently introduced multi‐coil hardware has proven that MRI‐relevant magnetic fields can also be created by a generic set of localized coils producing non‐orthogonal fields. As a step towards establishing a purely multi‐coil‐based MRI field generation system, the feasibility of performing conventional Cartesian k‐space encoding and echo‐planar imaging (EPI), as well as concurrent encoding and shimming is demonstrated in this study. Methods: We report the use of Dynamic Multi‐Coil Technique (DYNAMITE) for combined Cartesian encoding and shimming, and EPI using a 48‐channel multi‐coil system. Experiments were performed on phantom objects and biological specimens in a 9.4 T pre‐clinical scanner. Cartesian Fourier‐encoded MRI and EPI were implemented whereby the magnetic fields required for encoding of the three orthogonal spatial dimensions were entirely based on linear combinations of multi‐coil fields. Furthermore, DYNAMITE imaging was augmented by concurrent DYNAMITE shimming with the same hardware. Results: DYNAMITE‐based MR and echo‐planar images were indistinguishable from those acquired with the conventional linear imaging gradients provided by the scanner. In experiments with concurrent DYNAMITE shimming and imaging, shim challenges that would result in extreme spatial distortion and signal loss wereAbstract : Purpose: Spatial encoding and shimming in MRI have traditionally been performed using dedicated coils that generate orthogonal spherical harmonic fields. The recently introduced multi‐coil hardware has proven that MRI‐relevant magnetic fields can also be created by a generic set of localized coils producing non‐orthogonal fields. As a step towards establishing a purely multi‐coil‐based MRI field generation system, the feasibility of performing conventional Cartesian k‐space encoding and echo‐planar imaging (EPI), as well as concurrent encoding and shimming is demonstrated in this study. Methods: We report the use of Dynamic Multi‐Coil Technique (DYNAMITE) for combined Cartesian encoding and shimming, and EPI using a 48‐channel multi‐coil system. Experiments were performed on phantom objects and biological specimens in a 9.4 T pre‐clinical scanner. Cartesian Fourier‐encoded MRI and EPI were implemented whereby the magnetic fields required for encoding of the three orthogonal spatial dimensions were entirely based on linear combinations of multi‐coil fields. Furthermore, DYNAMITE imaging was augmented by concurrent DYNAMITE shimming with the same hardware. Results: DYNAMITE‐based MR and echo‐planar images were indistinguishable from those acquired with the conventional linear imaging gradients provided by the scanner. In experiments with concurrent DYNAMITE shimming and imaging, shim challenges that would result in extreme spatial distortion and signal loss were corrected very effectively with more than 92% signal recovery in case of extreme Z 2 shim challenge that resulted in complete signal dephasing in most slices. Conclusions: We demonstrate the first successful implementation of combined DYNAMITE imaging and shimming and show the feasibility of performing EPI with DYNAMITE hardware. Our results substantiate the potential of multi‐coil hardware as a full‐fledged imaging and shimming system, with additional potential benefits of reduced echo‐time and risk of peripheral nerve stimulation while performing EPI. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 81:Issue 2(2019)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 81:Issue 2(2019)
- Issue Display:
- Volume 81, Issue 2 (2019)
- Year:
- 2019
- Volume:
- 81
- Issue:
- 2
- Issue Sort Value:
- 2019-0081-0002-0000
- Page Start:
- 1424
- Page End:
- 1433
- Publication Date:
- 2018-10-10
- Subjects:
- dynamic shimming -- encoding -- EPI -- non‐linear gradients -- multi‐coil
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.27408 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23370.xml