Improved compressed sensing and super‐resolution of cardiac diffusion MRI with structure‐guided total variation. Issue 4 (3rd March 2020)
- Record Type:
- Journal Article
- Title:
- Improved compressed sensing and super‐resolution of cardiac diffusion MRI with structure‐guided total variation. Issue 4 (3rd March 2020)
- Main Title:
- Improved compressed sensing and super‐resolution of cardiac diffusion MRI with structure‐guided total variation
- Authors:
- Teh, Irvin
McClymont, Darryl
Carruth, Eric
Omens, Jeffrey
McCulloch, Andrew
Schneider, Jürgen E. - Abstract:
- Abstract : Purpose: Structure‐guided total variation is a recently introduced prior that allows reconstruction of images using knowledge of the location and orientation of edges in a reference image. In this work, we demonstrate the advantages of a variant of structure‐guided total variation known as directional total variation (DTV), over traditional total variation (TV), in the context of compressed‐sensing reconstruction and super‐resolution. Methods: We compared TV and DTV in retrospectively undersampled ex vivo diffusion tensor imaging and diffusion spectrum imaging data from healthy, sham, and hypertrophic rat hearts. Results: In compressed sensing at an undersampling factor of 8, the RMS error of mean diffusivity and fractional anisotropy relative to the fully sampled ground truth were 44% and 20% lower in DTV compared with TV. In super‐resolution, these values were 29% and 14%, respectively. Similarly, we observed improvements in helix angle, transverse angle, sheetlet elevation, and sheetlet azimuth. The RMS error of the diffusion kurtosis in the undersampled data relative to the ground truth was uniformly lower (22% on average) with DTV compared to TV. Conclusion: Acquiring one fully sampled non‐diffusion‐weighted image and 10 diffusion‐weighted images at 8× undersampling would result in an 80% net reduction in data needed. We demonstrate efficacy of the DTV algorithm over TV in reducing data sampling requirements, which can be translated into higher apparentAbstract : Purpose: Structure‐guided total variation is a recently introduced prior that allows reconstruction of images using knowledge of the location and orientation of edges in a reference image. In this work, we demonstrate the advantages of a variant of structure‐guided total variation known as directional total variation (DTV), over traditional total variation (TV), in the context of compressed‐sensing reconstruction and super‐resolution. Methods: We compared TV and DTV in retrospectively undersampled ex vivo diffusion tensor imaging and diffusion spectrum imaging data from healthy, sham, and hypertrophic rat hearts. Results: In compressed sensing at an undersampling factor of 8, the RMS error of mean diffusivity and fractional anisotropy relative to the fully sampled ground truth were 44% and 20% lower in DTV compared with TV. In super‐resolution, these values were 29% and 14%, respectively. Similarly, we observed improvements in helix angle, transverse angle, sheetlet elevation, and sheetlet azimuth. The RMS error of the diffusion kurtosis in the undersampled data relative to the ground truth was uniformly lower (22% on average) with DTV compared to TV. Conclusion: Acquiring one fully sampled non‐diffusion‐weighted image and 10 diffusion‐weighted images at 8× undersampling would result in an 80% net reduction in data needed. We demonstrate efficacy of the DTV algorithm over TV in reducing data sampling requirements, which can be translated into higher apparent resolution and potentially shorter scan times. This method would be equally applicable in diffusion MRI applications outside the heart. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 84:Issue 4(2020)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 84:Issue 4(2020)
- Issue Display:
- Volume 84, Issue 4 (2020)
- Year:
- 2020
- Volume:
- 84
- Issue:
- 4
- Issue Sort Value:
- 2020-0084-0004-0000
- Page Start:
- 1868
- Page End:
- 1880
- Publication Date:
- 2020-03-03
- Subjects:
- cardiac MRI -- compressed sensing -- diffusion kurtosis -- diffusion tensor imaging -- directional total variation -- super‐resolution
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.28245 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23367.xml