A Novel Computed Tomography Image Reconstruction for Improving Visualization of Pulmonary Vasculature: Comparison Between Preprocessing and Postprocessing Images Using a Contrast Enhancement Boost Technique. Issue 5 (September 2022)
- Record Type:
- Journal Article
- Title:
- A Novel Computed Tomography Image Reconstruction for Improving Visualization of Pulmonary Vasculature: Comparison Between Preprocessing and Postprocessing Images Using a Contrast Enhancement Boost Technique. Issue 5 (September 2022)
- Main Title:
- A Novel Computed Tomography Image Reconstruction for Improving Visualization of Pulmonary Vasculature: Comparison Between Preprocessing and Postprocessing Images Using a Contrast Enhancement Boost Technique
- Authors:
- Otgonbaatar, Chuluunbaatar
Ryu, Jae-Kyun
Shim, Hackjoon
Jeon, Pil-Hyun
Jeon, Sang-Hyun
Kim, Jin Woo
Ko, Sung Min
Kim, Hyunjung - Abstract:
- Abstract : Objective: This study aimed to evaluate chest computed tomography (CT) angiography image quality using the contrast enhancement (CE)–boost technique compared with conventional images. Methods: Forty patients who underwent contrast-enhanced chest CT were included. Combined CT angiography images of the iodinated image obtained from the subtraction of nonenhanced CT images and CT angiography images were used to generate CE-boost images. Computed tomography attenuation, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) for the right and left pulmonary arteries as the central and subsegmental arteries as peripheral vessels were assessed. Subjective image quality was rated on a 5-point scale by 2 radiologists. Image quality was assessed using a paired t test. Results: Computed tomography attenuation in the main pulmonary artery was significantly higher for the CE-boost images (311.05 ± 91.94) than for the conventional images (221.25 ± 61.21, P < 0.001). Similarly, the CE-boost images resulted in significantly higher CT attenuation in the subsegmental arteries (right, 305.34 ± 90.13; left, 313.05 ± 97.21) than in the conventional images (right, 218.45 ± 63.16; left, 223.89 ± 74.27). The CE-boost technique demonstrated marked improvement in the visualization of the peripheral pulmonary artery without the administration of a higher iodine delivery rate. The mean SNR and CNR were also significantly higher in the central and peripheral vessels in the CE-boostAbstract : Objective: This study aimed to evaluate chest computed tomography (CT) angiography image quality using the contrast enhancement (CE)–boost technique compared with conventional images. Methods: Forty patients who underwent contrast-enhanced chest CT were included. Combined CT angiography images of the iodinated image obtained from the subtraction of nonenhanced CT images and CT angiography images were used to generate CE-boost images. Computed tomography attenuation, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) for the right and left pulmonary arteries as the central and subsegmental arteries as peripheral vessels were assessed. Subjective image quality was rated on a 5-point scale by 2 radiologists. Image quality was assessed using a paired t test. Results: Computed tomography attenuation in the main pulmonary artery was significantly higher for the CE-boost images (311.05 ± 91.94) than for the conventional images (221.25 ± 61.21, P < 0.001). Similarly, the CE-boost images resulted in significantly higher CT attenuation in the subsegmental arteries (right, 305.34 ± 90.13; left, 313.05 ± 97.21) than in the conventional images (right, 218.45 ± 63.16; left, 223.89 ± 74.27). The CE-boost technique demonstrated marked improvement in the visualization of the peripheral pulmonary artery without the administration of a higher iodine delivery rate. The mean SNR and CNR were also significantly higher in the central and peripheral vessels in the CE-boost images than in the conventional images ( P < 0.001). In the subjective analysis, the image contrast and vascular contrast edge were significantly higher for the CE-boost images than for conventional images ( P < 0.001). Conclusions: The CE-boost technique increases not only the visualization of peripheral arteries by improving vascular attenuation but also the SNR and CNR. … (more)
- Is Part Of:
- Journal of computer assisted tomography. Volume 46:Issue 5(2022)
- Journal:
- Journal of computer assisted tomography
- Issue:
- Volume 46:Issue 5(2022)
- Issue Display:
- Volume 46, Issue 5 (2022)
- Year:
- 2022
- Volume:
- 46
- Issue:
- 5
- Issue Sort Value:
- 2022-0046-0005-0000
- Page Start:
- 729
- Page End:
- 734
- Publication Date:
- 2022-09
- Subjects:
- pulmonary embolism -- image reconstruction -- multidetector computed tomography -- image quality enhancement
Tomography -- Periodicals
Tomography -- Periodicals
Tomography
Periodicals
616.0757 - Journal URLs:
- http://journals.lww.com/jcat/pages/default.aspx ↗
http://ovidsp.tx.ovid.com ↗
http://www.jcat.org ↗
http://www.rad.bqsm.edu/jcat ↗
http://journals.lww.com ↗
http://www.lww.com/Product/0363-8715 ↗ - DOI:
- 10.1097/RCT.0000000000001347 ↗
- Languages:
- English
- ISSNs:
- 0363-8715
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4963.650000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23333.xml