Comparison between cuff-based and invasive systolic blood pressure amplification. Issue 10 (23rd October 2022)
- Record Type:
- Journal Article
- Title:
- Comparison between cuff-based and invasive systolic blood pressure amplification. Issue 10 (23rd October 2022)
- Main Title:
- Comparison between cuff-based and invasive systolic blood pressure amplification
- Authors:
- Bui, Tan V.
Picone, Dean S.
Schultz, Martin G.
Armstrong, Matthew K.
Peng, Xiaoqing
Black, J. Andrew
Dwyer, Nathan
Roberts-Thomson, Philip
Adams, Heath
Hughes, Alun D.
Sharman, James E. - Abstract:
- Abstract : Objective: Accurate measurement of central blood pressure (BP) using upper arm cuff-based methods is associated with several factors, including determining the level of systolic BP (SBP) amplification. This study aimed to determine the agreement between cuff-based and invasively measured SBP amplification. Methods: Patients undergoing coronary angiography had invasive SBP amplification (brachial SBP – central SBP) measured simultaneously with cuff-based SBP amplification using a commercially available central BP device (device 1: Sphygmocor Xcel; n = 171, 70% men, 60 ± 10 years) and a now superseded model of a central BP device (device 2: Uscom BP+; n = 52, 83% men, 62 ± 10 years). Results: Mean difference (±2SD, limits of agreement) between cuff-based and invasive SBP amplification was 4 mmHg (−12, +20 mmHg, P < 0.001) for device 1 and −2 mmHg (−14, +10 mmHg, P = 0.10) for device 2. Both devices systematically overestimated SBP amplification at lower levels and underestimated at higher levels of invasive SBP amplification, but with stronger bias for device 1 ( r = −0.68 vs. r = −0.52; Z = 2.72; P = 0.008). Concordance of cuff-based and invasive SBP amplification across quartiles of invasive SBP amplification was low, particularly in the lowest and highest quartiles. The root mean square errors from regression between cuff-based central SBP and brachial SBP were significantly lower (indicating less variability) than from invasive regression models ( PAbstract : Objective: Accurate measurement of central blood pressure (BP) using upper arm cuff-based methods is associated with several factors, including determining the level of systolic BP (SBP) amplification. This study aimed to determine the agreement between cuff-based and invasively measured SBP amplification. Methods: Patients undergoing coronary angiography had invasive SBP amplification (brachial SBP – central SBP) measured simultaneously with cuff-based SBP amplification using a commercially available central BP device (device 1: Sphygmocor Xcel; n = 171, 70% men, 60 ± 10 years) and a now superseded model of a central BP device (device 2: Uscom BP+; n = 52, 83% men, 62 ± 10 years). Results: Mean difference (±2SD, limits of agreement) between cuff-based and invasive SBP amplification was 4 mmHg (−12, +20 mmHg, P < 0.001) for device 1 and −2 mmHg (−14, +10 mmHg, P = 0.10) for device 2. Both devices systematically overestimated SBP amplification at lower levels and underestimated at higher levels of invasive SBP amplification, but with stronger bias for device 1 ( r = −0.68 vs. r = −0.52; Z = 2.72; P = 0.008). Concordance of cuff-based and invasive SBP amplification across quartiles of invasive SBP amplification was low, particularly in the lowest and highest quartiles. The root mean square errors from regression between cuff-based central SBP and brachial SBP were significantly lower (indicating less variability) than from invasive regression models ( P < 0.001). Conclusions: Irrespective of the difference from invasive measurements, cuff-based estimates of SBP amplification showed evidence of proportional systematic bias and had less individual variability. These observations could provide insights on how to improve the performance of cuff-based central BP. … (more)
- Is Part Of:
- Journal of hypertension. Volume 40:Issue 10(2022)
- Journal:
- Journal of hypertension
- Issue:
- Volume 40:Issue 10(2022)
- Issue Display:
- Volume 40, Issue 10 (2022)
- Year:
- 2022
- Volume:
- 40
- Issue:
- 10
- Issue Sort Value:
- 2022-0040-0010-0000
- Page Start:
- 2037
- Page End:
- 2044
- Publication Date:
- 2022-10-23
- Subjects:
- angiography -- blood pressure determination -- pulse wave analysis
Hypertension -- Periodicals
Hypertension -- Periodicals
616.132005 - Journal URLs:
- http://firstsearch.oclc.org ↗
http://journals.lww.com/jhypertension/pages/default.aspx ↗
http://ovidsp.ovid.com/ovidweb.cgi?T=JS&NEWS=n&CSC=Y&PAGE=toc&D=yrovft&AN=00004872-000000000-00000 ↗
http://www.jhypertension.com/ ↗
http://journals.lww.com/pages/default.aspx ↗ - DOI:
- 10.1097/HJH.0000000000003228 ↗
- Languages:
- English
- ISSNs:
- 1473-5598
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5004.510000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 23332.xml