Characterisation of graphite-based material for dosimetry in the mammographic energy range. (November 2022)
- Record Type:
- Journal Article
- Title:
- Characterisation of graphite-based material for dosimetry in the mammographic energy range. (November 2022)
- Main Title:
- Characterisation of graphite-based material for dosimetry in the mammographic energy range
- Authors:
- Bradley, D.A.
Mat Nawi, Siti Nurasiah
Sani, S.F Abdul
Khandaker, Mayeen Uddin
Almugren, K.S. - Abstract:
- Abstract: Present work explores the use of carbon-based materials as novel material for in-vivo radiation dosimetry during routine screening mammography, in part to reliably predict the average glandular dose (AGD) imparted to the patient. The study herein proposes the use of highly uniform 0.3 mm of 2B and HB grade polymer pencil-lead graphite (PPLG) i.e. approximately 95 wt % and 61 wt % graphite content, respectively and also using graphite produced commercially in the form of 50 μm thick sheets, addressing variation in lattice structure and defects resulting from low x-ray doses. Comparison was made with highly-oriented pyrolytic graphite (HOPG), a pure ordered synthetic form of graphite. Due to their small size and distinctive shape, these samples can be placed on the body surface in the field of view during the examination without compromising the mammogram reading. Investigations of thermo- and photoluminescence dose dependence, as well as changes in Raman spectroscopic features, have been conducted with a focus on the relationship between absorbed radiation energy and induced material changes within the dose range 3–11 mGy. The influences, are readily understood to relate to defect density, structural alterations and radiation-driven thermal annealing, all irradiation alterations occurring at the microscopic level. Within the doses study, all graphite samples demonstrated excellent linear response in respect of thermoluminescence yield per unit mass. In terms ofAbstract: Present work explores the use of carbon-based materials as novel material for in-vivo radiation dosimetry during routine screening mammography, in part to reliably predict the average glandular dose (AGD) imparted to the patient. The study herein proposes the use of highly uniform 0.3 mm of 2B and HB grade polymer pencil-lead graphite (PPLG) i.e. approximately 95 wt % and 61 wt % graphite content, respectively and also using graphite produced commercially in the form of 50 μm thick sheets, addressing variation in lattice structure and defects resulting from low x-ray doses. Comparison was made with highly-oriented pyrolytic graphite (HOPG), a pure ordered synthetic form of graphite. Due to their small size and distinctive shape, these samples can be placed on the body surface in the field of view during the examination without compromising the mammogram reading. Investigations of thermo- and photoluminescence dose dependence, as well as changes in Raman spectroscopic features, have been conducted with a focus on the relationship between absorbed radiation energy and induced material changes within the dose range 3–11 mGy. The influences, are readily understood to relate to defect density, structural alterations and radiation-driven thermal annealing, all irradiation alterations occurring at the microscopic level. Within the doses study, all graphite samples demonstrated excellent linear response in respect of thermoluminescence yield per unit mass. In terms of sensitivity, 2B samples outperformed HB, graphite sheet (GS), and HOPG. In mammographic studies graphite sheets show particular promise as a probe of skin dose, with negligible prospect for interference with the breast image an individual patient during routine screening, closely matching the effective atomic number of soft tissues, additionally providing the basis of a low-cost yet highly effective system for studies of radiation-driven changes in carbon. … (more)
- Is Part Of:
- Radiation physics and chemistry. Volume 201(2022)
- Journal:
- Radiation physics and chemistry
- Issue:
- Volume 201(2022)
- Issue Display:
- Volume 201, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 201
- Issue:
- 2022
- Issue Sort Value:
- 2022-0201-2022-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-11
- Subjects:
- Carbon-based materials -- X-ray irradiation -- TL dosimetry -- Mammography -- Dosimetric characterization
Radiation chemistry -- Periodicals
Radiometry -- Periodicals
Radiation -- Periodicals
Chimie sous rayonnement -- Périodiques
539.2 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0969806X ↗
http://www.elsevier.com/journals ↗
http://www.journals.elsevier.com/radiation-physics-and-chemistry/ ↗ - DOI:
- 10.1016/j.radphyschem.2022.110405 ↗
- Languages:
- English
- ISSNs:
- 0969-806X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7227.984000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23327.xml