Aortic valve neocuspidization using autologous pericardium compared to surgical aortic valve replacement. Issue 10 (23rd July 2022)
- Record Type:
- Journal Article
- Title:
- Aortic valve neocuspidization using autologous pericardium compared to surgical aortic valve replacement. Issue 10 (23rd July 2022)
- Main Title:
- Aortic valve neocuspidization using autologous pericardium compared to surgical aortic valve replacement
- Authors:
- Boehm, Johannes
Vitanova, Keti
Prinzing, Anatol
Krane, Markus
Lange, Rüdiger - Abstract:
- Abstract: Introduction: Aortic valve neocuspidization (AVNeo) for trileaflet aortic valve reconstruction using autologous pericardium (Ozaki procedure) depicts an encouraging new technique for the surgical treatment of aortic valve pathologies. The current study analyzes the early hemodynamic outcome of AVneo compared with surgical aortic valve replacement (SAVR) using the Abbott/St. Jude Trifecta aortic valve biological prostheses. Methods: All patients who underwent either AVNeo or SAVR between March 2017 and April 2020 were included. Exclusion criteria were emergency cases, endocarditis, redo‐ or additional root procedures. Main endpoints were differences between the two groups in terms of the effective orifice area (EOA) and the effective orifice area index (EOAI) at discharge. Results: During the study period, 105 AVNeo patients and 458 SAVR patients met the inclusion criteria. EOA was significantly higher in the AVNeo group (2.4 cm 2 ± 0.8 vs. 2.1 cm 2 /m 2 ± 0.6 in the SAVR group, respectively; p < .001). Multiple regression analysis, including AVNeo, annulus size, bicuspid valve, preoperative stenosis, left ventricular ejection fraction (LVEF), and diastolic diameter (LVEDD) found two factors, which favor larger EOA: Annulus size ( p < .0001) and AVneo ( p = .005). EOAI was significantly higher in the AVNeo group (1.23 ± 0.4 vs. 1.02 cm 2 /m 2 ± 0.3, respectively; p < .001). Multiple regression analysis for EOAI showed effects for AVneo ( p = .005) andAbstract: Introduction: Aortic valve neocuspidization (AVNeo) for trileaflet aortic valve reconstruction using autologous pericardium (Ozaki procedure) depicts an encouraging new technique for the surgical treatment of aortic valve pathologies. The current study analyzes the early hemodynamic outcome of AVneo compared with surgical aortic valve replacement (SAVR) using the Abbott/St. Jude Trifecta aortic valve biological prostheses. Methods: All patients who underwent either AVNeo or SAVR between March 2017 and April 2020 were included. Exclusion criteria were emergency cases, endocarditis, redo‐ or additional root procedures. Main endpoints were differences between the two groups in terms of the effective orifice area (EOA) and the effective orifice area index (EOAI) at discharge. Results: During the study period, 105 AVNeo patients and 458 SAVR patients met the inclusion criteria. EOA was significantly higher in the AVNeo group (2.4 cm 2 ± 0.8 vs. 2.1 cm 2 /m 2 ± 0.6 in the SAVR group, respectively; p < .001). Multiple regression analysis, including AVNeo, annulus size, bicuspid valve, preoperative stenosis, left ventricular ejection fraction (LVEF), and diastolic diameter (LVEDD) found two factors, which favor larger EOA: Annulus size ( p < .0001) and AVneo ( p = .005). EOAI was significantly higher in the AVNeo group (1.23 ± 0.4 vs. 1.02 cm 2 /m 2 ± 0.3, respectively; p < .001). Multiple regression analysis for EOAI showed effects for AVneo ( p = .005) and bicuspid valve ( p = .029). Mean pressure gradients (MPG) were lower in the AVNeo group than in the SAVR group (AVNeo: MPG = 8.0 mmHg ± 3.6 vs. SAVR: MPG = 8.3 mmHg ± 3.6), but this finding did not reach statistical significance ( p = .091). Conclusions: AVNeo shows significantly larger EOA and EOAI compared to SAVR using the Abbott/St. Jude Trifecta aortic valve biological prostheses. … (more)
- Is Part Of:
- Journal of cardiac surgery. Volume 37:Issue 10(2022)
- Journal:
- Journal of cardiac surgery
- Issue:
- Volume 37:Issue 10(2022)
- Issue Display:
- Volume 37, Issue 10 (2022)
- Year:
- 2022
- Volume:
- 37
- Issue:
- 10
- Issue Sort Value:
- 2022-0037-0010-0000
- Page Start:
- 3110
- Page End:
- 3116
- Publication Date:
- 2022-07-23
- Subjects:
- cardiovascular research -- valve repair/replacement
Heart -- Surgery -- Periodicals
617.412005 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1540-8191 ↗
http://www.blackwell-synergy.com/rd.asp?goto=journal&code=jcs ↗
http://onlinelibrary.wiley.com/ ↗
http://firstsearch.oclc.org ↗ - DOI:
- 10.1111/jocs.16800 ↗
- Languages:
- English
- ISSNs:
- 0886-0440
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.863500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23311.xml