Compliance study of hip protector users for prevention of fragility fracture: A pilot randomized trial. Issue 4 (14th August 2022)
- Record Type:
- Journal Article
- Title:
- Compliance study of hip protector users for prevention of fragility fracture: A pilot randomized trial. Issue 4 (14th August 2022)
- Main Title:
- Compliance study of hip protector users for prevention of fragility fracture: A pilot randomized trial
- Authors:
- Wong, Man Sang
Wu, Hui Dong
Beygi, Babak Hassan
Zhang, Qian
Lin, Yangmin
Chan, Wing Sheung
Lou, Edmond - Abstract:
- Abstract : Background: Hip protectors have been widely used for hip fracture prevention in the elderly, but its efficacy remains controversial. Users' compliance to hip protector is an important factor for its efficacy. However, the assessment of users' compliance tended to be subjective and unreliable in the past. Objectives: To quantify the elderly's compliance to hip protectors and investigate the effect of different underpant designs on the elderly's compliance. Study Design: A pilot randomized trial. Methods: Thirty-one participants were recruited and provided with hip protectors in which compliance monitors were installed and delivered with three pairs of either the conventional underpants or the purpose-design underpants randomly. Participants were encouraged to use the hip protectors with the assigned underpants for whole day. After 4 weeks, compliance data were downloaded from the compliance monitors. Participants were also asked to fill a survey form for acceptance analysis. The Spearman correlation coefficient and the Wilcoxon signed-rank test/2 independent samples t test/Mann-Whitney U test were used for the corresponding statistical analyses. Results: Thirty-one participants were recruited initially. Eighteen participants were excluded from instrumented compliance analysis because of limited or no data collection. The data of the resting 13 participants (six in the conventional underpants group and seven in purpose-design underpants group) were analyzed andAbstract : Background: Hip protectors have been widely used for hip fracture prevention in the elderly, but its efficacy remains controversial. Users' compliance to hip protector is an important factor for its efficacy. However, the assessment of users' compliance tended to be subjective and unreliable in the past. Objectives: To quantify the elderly's compliance to hip protectors and investigate the effect of different underpant designs on the elderly's compliance. Study Design: A pilot randomized trial. Methods: Thirty-one participants were recruited and provided with hip protectors in which compliance monitors were installed and delivered with three pairs of either the conventional underpants or the purpose-design underpants randomly. Participants were encouraged to use the hip protectors with the assigned underpants for whole day. After 4 weeks, compliance data were downloaded from the compliance monitors. Participants were also asked to fill a survey form for acceptance analysis. The Spearman correlation coefficient and the Wilcoxon signed-rank test/2 independent samples t test/Mann-Whitney U test were used for the corresponding statistical analyses. Results: Thirty-one participants were recruited initially. Eighteen participants were excluded from instrumented compliance analysis because of limited or no data collection. The data of the resting 13 participants (six in the conventional underpants group and seven in purpose-design underpants group) were analyzed and showed an average instrumented compliance of 77.5% which was lower than the average self-reporting compliance (83.3%) of all the available 23 participants (eight of 31 became wheelchair-bounded). Participants' compliance was positively correlated with their acceptance to the hip protectors and significantly higher in the purpose-design underpants group than in the conventional underpants group ( P < 0.05). Conclusions: This pilot study demonstrated a feasible protocol for compliance quantification of the elderly to the hip protectors, the importance to have an objective compliance measure to assess users' actual compliance, and purpose-design underpants could improve the users' compliance. Future studies with long-term observation and large sample size deserve further proof of the current findings. … (more)
- Is Part Of:
- Prosthetics and orthotics international. Volume 46:Issue 4(2022)
- Journal:
- Prosthetics and orthotics international
- Issue:
- Volume 46:Issue 4(2022)
- Issue Display:
- Volume 46, Issue 4 (2022)
- Year:
- 2022
- Volume:
- 46
- Issue:
- 4
- Issue Sort Value:
- 2022-0046-0004-0000
- Page Start:
- e392
- Page End:
- e397
- Publication Date:
- 2022-08-14
- Subjects:
- hip fracture -- hip protector -- compliance monitor -- elderly
Orthopedic apparatus -- Periodicals
Prosthesis -- Periodicals
Implants, Artificial -- Periodicals
617.905 - Journal URLs:
- http://poi.sagepub.com/content/by/year ↗
https://journals.lww.com/poijournal/pages/default.aspx ↗
http://www.uk.sagepub.com/home.nav ↗
http://informahealthcare.com/loi/poi ↗
http://www.tandf.co.uk/journals/titles/03093646.asp ↗ - DOI:
- 10.1097/PXR.0000000000000098 ↗
- Languages:
- English
- ISSNs:
- 0309-3646
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6935.500000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23304.xml