Measurement of global mechanical properties of human thorax: Costal cartilage. (September 2022)
- Record Type:
- Journal Article
- Title:
- Measurement of global mechanical properties of human thorax: Costal cartilage. (September 2022)
- Main Title:
- Measurement of global mechanical properties of human thorax
- Authors:
- Gradischar, Andreas
Lebschy, Carola
Krach, Wolfgang
Krall, Marcell
Fediuk, Melanie
Gieringer, Anja
Smolle-Jüttner, Freyja
Hammer, Niels
Beyer, Benoît
Smolle, Josef
Schäfer, Ute - Abstract:
- Abstract: Surgical resection of chest wall tumours may lead to a loss of ribcage stability and requires reconstruction to allow for physical thorax functioning. When titanium implants are used especially for larger, lateral defects, they tend to break. Implant failures are mainly due to specific mechanical requirements for chest-wall reconstruction which must mimic the physiological properties and which are not yet met by available implants. In order to develop new implants, the mechanical characteristics of ribs, joints and cartilages are investigated. Rib loading is highly dependent on the global thorax kinematics, making implant development substantially challenging. Costal cartilage contributes vastly to the entire thorax load-deformation behaviour, and also to rib loading patterns. Computational models of the thoracic cage require mechanical properties on the global stiffness, to simulate rib kinematics and evaluate stresses in the ribs and costal cartilage. In this study the mechanical stiffness of human costal cartilage is assessed with bending, torsion and tensile tests. The elastic moduli for the bending in four major directions ranged from 2.2 to 60.8 MPa, shear moduli ranged from 5.7 to 24.7 MPa for torsion, and tensile elastic moduli ranging from 5.6 to 29.6 MPa. This article provides mechanical properties for costal cartilage. The results of these measurements are used for the development of a whole thorax finite element model to investigate ribcage biomechanicsAbstract: Surgical resection of chest wall tumours may lead to a loss of ribcage stability and requires reconstruction to allow for physical thorax functioning. When titanium implants are used especially for larger, lateral defects, they tend to break. Implant failures are mainly due to specific mechanical requirements for chest-wall reconstruction which must mimic the physiological properties and which are not yet met by available implants. In order to develop new implants, the mechanical characteristics of ribs, joints and cartilages are investigated. Rib loading is highly dependent on the global thorax kinematics, making implant development substantially challenging. Costal cartilage contributes vastly to the entire thorax load-deformation behaviour, and also to rib loading patterns. Computational models of the thoracic cage require mechanical properties on the global stiffness, to simulate rib kinematics and evaluate stresses in the ribs and costal cartilage. In this study the mechanical stiffness of human costal cartilage is assessed with bending, torsion and tensile tests. The elastic moduli for the bending in four major directions ranged from 2.2 to 60.8 MPa, shear moduli ranged from 5.7 to 24.7 MPa for torsion, and tensile elastic moduli ranging from 5.6 to 29.6 MPa. This article provides mechanical properties for costal cartilage. The results of these measurements are used for the development of a whole thorax finite element model to investigate ribcage biomechanics and subsequently to design improved rib implants. … (more)
- Is Part Of:
- Journal of biomechanics. Volume 142(2022)
- Journal:
- Journal of biomechanics
- Issue:
- Volume 142(2022)
- Issue Display:
- Volume 142, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 142
- Issue:
- 2022
- Issue Sort Value:
- 2022-0142-2022-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-09
- Subjects:
- Costal cartilage -- Biomechanical properties -- Ribcage -- Biomechanical tests
Animal mechanics -- Periodicals
Biomechanics -- Periodicals
Biomechanics -- Periodicals
Mécanique animale -- Périodiques
Biomécanique -- Périodiques
Electronic journals
571.4305 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00219290 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/00219290 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/00219290 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jbiomech.2022.111242 ↗
- Languages:
- English
- ISSNs:
- 0021-9290
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4953.600000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23293.xml