Non-intrusive PODI-ROM for patient-specific aortic blood flow in presence of a LVAD device. (September 2022)
- Record Type:
- Journal Article
- Title:
- Non-intrusive PODI-ROM for patient-specific aortic blood flow in presence of a LVAD device. (September 2022)
- Main Title:
- Non-intrusive PODI-ROM for patient-specific aortic blood flow in presence of a LVAD device
- Authors:
- Girfoglio, Michele
Ballarin, Francesco
Infantino, Giuseppe
Nicoló, Francesca
Montalto, Andrea
Rozza, Gianluigi
Scrofani, Roberto
Comisso, Marina
Musumeci, Francesco - Abstract:
- Highlights: Model order reduction for blood flows to enhance computational efficiency (real time). Patient specific numerical simulations. Efficient Haemodynamic simulations. Abstract: Left ventricular assist devices (LVADs) are used to provide haemodynamic support to patients with critical cardiac failure. Severe complications can occur because of the modifications of the blood flow in the aortic region. In this work, the effect of a continuous flow LVAD device on the aortic flow is investigated by means of a non-intrusive reduced order model (ROM) built using the proper orthogonal decomposition with interpolation (PODI) method based on radial basis functions (RBF). The full order model (FOM) is represented by the incompressible Navier-Stokes equations discretized by using a Finite Volume (FV) technique, coupled with three-element Windkessel models to enforce outlet boundary conditions in a multi-scale approach. A patient-specific framework is proposed: a personalized geometry reconstructed from Computed Tomography (CT) images is used and the individualization of the coefficients of the three-element Windkessel models is based on experimental data provided by the Right Heart Catheterization (RHC) and Echocardiography (ECHO) tests. At FOM level, we also consider the pre-surgery configuration in order to further validate the predictive capabilities of the model in several contexts. The ROM has been tested by considering a parametric setting with respect to the LVAD flow,Highlights: Model order reduction for blood flows to enhance computational efficiency (real time). Patient specific numerical simulations. Efficient Haemodynamic simulations. Abstract: Left ventricular assist devices (LVADs) are used to provide haemodynamic support to patients with critical cardiac failure. Severe complications can occur because of the modifications of the blood flow in the aortic region. In this work, the effect of a continuous flow LVAD device on the aortic flow is investigated by means of a non-intrusive reduced order model (ROM) built using the proper orthogonal decomposition with interpolation (PODI) method based on radial basis functions (RBF). The full order model (FOM) is represented by the incompressible Navier-Stokes equations discretized by using a Finite Volume (FV) technique, coupled with three-element Windkessel models to enforce outlet boundary conditions in a multi-scale approach. A patient-specific framework is proposed: a personalized geometry reconstructed from Computed Tomography (CT) images is used and the individualization of the coefficients of the three-element Windkessel models is based on experimental data provided by the Right Heart Catheterization (RHC) and Echocardiography (ECHO) tests. At FOM level, we also consider the pre-surgery configuration in order to further validate the predictive capabilities of the model in several contexts. The ROM has been tested by considering a parametric setting with respect to the LVAD flow, which is a crucial parameter of the problem. We consider a parameter range that covers typical clinical values. The accuracy of the ROM is assessed against results obtained with the FOM both for primal, velocity and pressure, and derived quantities, wall shear stress (WSS). Finally, we briefly discuss the efficiency of our ROM approach. … (more)
- Is Part Of:
- Medical engineering & physics. Volume 107(2022)
- Journal:
- Medical engineering & physics
- Issue:
- Volume 107(2022)
- Issue Display:
- Volume 107, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 107
- Issue:
- 2022
- Issue Sort Value:
- 2022-0107-2022-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-09
- Subjects:
- LVAD -- Aortic hemodynamics -- Non intrusive model reduction -- Data-driven techniques
Biomedical engineering -- Periodicals
Biomedical Engineering -- Periodicals
Physics -- Periodicals
Génie biomédical -- Périodiques
Biomedical engineering
Electronic journals
Periodicals
610.28 - Journal URLs:
- http://www.medengphys.com ↗
http://www.sciencedirect.com/science/journal/13504533 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/13504533 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/13504533 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.medengphy.2022.103849 ↗
- Languages:
- English
- ISSNs:
- 1350-4533
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5527.323000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23309.xml