Effect of simulated brushing and disinfection on the surface roughness and color stability of CAD-CAM denture base materials. (October 2022)
- Record Type:
- Journal Article
- Title:
- Effect of simulated brushing and disinfection on the surface roughness and color stability of CAD-CAM denture base materials. (October 2022)
- Main Title:
- Effect of simulated brushing and disinfection on the surface roughness and color stability of CAD-CAM denture base materials
- Authors:
- Çakmak, Gülce
Donmez, Mustafa Borga
Akay, Canan
Atalay, Sevda
Silva de Paula, Marcella
Schimmel, Martin
Yilmaz, Burak - Abstract:
- Abstract: Purpose: To evaluate the effect of simulated brushing and chemical disinfection on the surface roughness and color stability of CAD-CAM denture base materials and to compare with those of a heat-cured denture base material. Material and methods: Disk-shaped specimens (Ø 10mm × 2 mm) were prepared from 3 CAD-CAM denture base resins (AvaDent, Ava; Merz M-PM, Merz; Polident d.o.o, Poli) and a heat-cured polymethylmethacrylate resin (Promolux, Conv) (n = 30). After polishing, baseline surface roughness (Ra ) and color coordinates were measured. The measurements were repeated after 20000 cycles of simulated brushing, and the specimens were divided into 3 groups according to disinfection protocol (distilled water, 1% sodium hypochlorite (NaOCl), and effervescent tablet) (n = 10). After 9 cleaning cycles over a period of 20 days, Ra and color coordinates were remeasured. Color differences (ΔE00 ) were calculated by using CIEDE2000 formula. One-way analysis of variance (ANOVA) and pairwise t-tests were used to analyze Ra and ΔE00 data, while repeated measures ANOVA test was used to compare baseline, after brush, and after disinfection Ra values (α = 0.05). Results: Brushing did not affect the Ra values of tested materials ( P ≥ .08). Both before and after brushing, Merz and Conv had higher Ra values than Poli and Ava ( P < .001). Among disinfectants, effervescent tablet led to the lowest Ra for Merz ( P = .003) and the highest Ra for Poli ( P ≤ .039). Only NaOClAbstract: Purpose: To evaluate the effect of simulated brushing and chemical disinfection on the surface roughness and color stability of CAD-CAM denture base materials and to compare with those of a heat-cured denture base material. Material and methods: Disk-shaped specimens (Ø 10mm × 2 mm) were prepared from 3 CAD-CAM denture base resins (AvaDent, Ava; Merz M-PM, Merz; Polident d.o.o, Poli) and a heat-cured polymethylmethacrylate resin (Promolux, Conv) (n = 30). After polishing, baseline surface roughness (Ra ) and color coordinates were measured. The measurements were repeated after 20000 cycles of simulated brushing, and the specimens were divided into 3 groups according to disinfection protocol (distilled water, 1% sodium hypochlorite (NaOCl), and effervescent tablet) (n = 10). After 9 cleaning cycles over a period of 20 days, Ra and color coordinates were remeasured. Color differences (ΔE00 ) were calculated by using CIEDE2000 formula. One-way analysis of variance (ANOVA) and pairwise t-tests were used to analyze Ra and ΔE00 data, while repeated measures ANOVA test was used to compare baseline, after brush, and after disinfection Ra values (α = 0.05). Results: Brushing did not affect the Ra values of tested materials ( P ≥ .08). Both before and after brushing, Merz and Conv had higher Ra values than Poli and Ava ( P < .001). Among disinfectants, effervescent tablet led to the lowest Ra for Merz ( P = .003) and the highest Ra for Poli ( P ≤ .039). Only NaOCl resulted in significant differences among the Ra of materials ( P < .001), as Merz and Conv had higher Ra values than Poli ( P ≤ .002). Repeated measures ANOVA revealed that effervescent tablet disinfection of Merz led to lower Ra values than those of baseline and after brushing ( P ≤ .042). After brushing, Ava and Conv had higher ΔE00 values compared with Merz and Poli (P ≤ .015). When compared with other disinfection protocols, effervescent tablet led to higher ΔE00 values for Merz and Poli ( P < .001). Significant differences were observed among materials when NaOCl was used; Conv had higher ΔE00 values than Ava and Merz ( P = .004). Conclusions: Brushing did not increase the surface roughness of materials. Disinfection protocol's effect on the surface roughness varied. The effect of brushing on the color of materials varied; color of Ava and Conv was affected from brushing more than the other materials. Color stability of materials varied depending on the disinfection protocol. Effervescent tablet caused higher color change with Merz and Poli compared with other disinfectants. NaOCl led to small color change for Poli, Ava, and Merz materials. Graphical abstract: Image 1 Highlights: Brushing did not affect the surface roughness. Disinfection protocol's effect on the surface roughness varied. Brushing caused a higher color change for Ava and Conv. Effervescent tablet caused higher color change with Merz and Poli. … (more)
- Is Part Of:
- Journal of the mechanical behavior of biomedical materials. Volume 134(2022)
- Journal:
- Journal of the mechanical behavior of biomedical materials
- Issue:
- Volume 134(2022)
- Issue Display:
- Volume 134, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 134
- Issue:
- 2022
- Issue Sort Value:
- 2022-0134-2022-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-10
- Subjects:
- CAD-CAM -- Color stability -- Denture base -- Disinfection -- Simulated brushing -- Surface roughness
Biomedical materials -- Periodicals
Biomedical materials -- Mechanical properties -- Periodicals
Biomedical materials
Biomedical materials -- Mechanical properties
Periodicals
Electronic journals
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/17516161 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jmbbm.2022.105390 ↗
- Languages:
- English
- ISSNs:
- 1751-6161
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5015.809000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23280.xml