Comparison of two point of care whole blood coagulation analysis devices and conventional coagulation tests as a predicting tool of perioperative bleeding in adult cardiac surgery—a pilot prospective observational study in Japan. Issue 11 (15th October 2019)
- Record Type:
- Journal Article
- Title:
- Comparison of two point of care whole blood coagulation analysis devices and conventional coagulation tests as a predicting tool of perioperative bleeding in adult cardiac surgery—a pilot prospective observational study in Japan. Issue 11 (15th October 2019)
- Main Title:
- Comparison of two point of care whole blood coagulation analysis devices and conventional coagulation tests as a predicting tool of perioperative bleeding in adult cardiac surgery—a pilot prospective observational study in Japan
- Authors:
- Terada, Rui
Ikeda, Toshiyuki
Mori, Yoshiteru
Yamazaki, Sho
Kashiwabara, Kosuke
Yamauchi, Haruo
Ono, Minoru
Yamada, Yoshitsugu
Okazaki, Hitoshi - Abstract:
- Abstract : BACKGROUND: It is widely accepted that Point‐of Care Test (PoCT) devices are useful in the detection of coagulopathies in situations of massive bleeding such as major cardiac surgery. These devices contribute to the reduction of blood transfusion. However, their implementation remains limited in Japan because of their cost and lack of health insurance support. STUDY DESIGN AND METHODS: Conventional coagulation tests and thromboelastography (TEG)/Sonoclot values were measured in 50 consecutive cardiac surgery cases. Clinical background information such as operative procedures was obtained from electronic medical records, and the theoretical perioperative total blood loss was calculated by measuring the hemoglobin content and total red blood cell transfusion volume. The correlation between perioperative total blood loss and the measured laboratory values or clinical parameters was evaluated by a multivariate linear regression analysis. The risk factors of the total amount of platelet transfusion and postoperative drain bleeding volume were similarly evaluated. RESULTS: No significant association between the estimated perioperative total blood loss (eTBL) and the laboratory measurements including conventional coagulation tests, TEG and Sonoclot was observed. On the other hand, postoperative drain bleeding volume was significantly associated with postoperative Sonoclot CR (p = 0.039) as well as preoperative use of oral anticoagulants and cell saver treated bloodAbstract : BACKGROUND: It is widely accepted that Point‐of Care Test (PoCT) devices are useful in the detection of coagulopathies in situations of massive bleeding such as major cardiac surgery. These devices contribute to the reduction of blood transfusion. However, their implementation remains limited in Japan because of their cost and lack of health insurance support. STUDY DESIGN AND METHODS: Conventional coagulation tests and thromboelastography (TEG)/Sonoclot values were measured in 50 consecutive cardiac surgery cases. Clinical background information such as operative procedures was obtained from electronic medical records, and the theoretical perioperative total blood loss was calculated by measuring the hemoglobin content and total red blood cell transfusion volume. The correlation between perioperative total blood loss and the measured laboratory values or clinical parameters was evaluated by a multivariate linear regression analysis. The risk factors of the total amount of platelet transfusion and postoperative drain bleeding volume were similarly evaluated. RESULTS: No significant association between the estimated perioperative total blood loss (eTBL) and the laboratory measurements including conventional coagulation tests, TEG and Sonoclot was observed. On the other hand, postoperative drain bleeding volume was significantly associated with postoperative Sonoclot CR (p = 0.039) as well as preoperative use of oral anticoagulants and cell saver treated blood volume. Platelet transfusion amount was significantly associated with post‐CBP PF and time to peak value of Sonoclot (p = 0.014 and 0.001, respectively). CONCLUSION: Sonoclot measurements may be useful to estimate the risks of postoperative bleeding and platelet transfusion in cardiac surgeries in Japan. … (more)
- Is Part Of:
- Transfusion. Volume 59:Issue 11(2019)
- Journal:
- Transfusion
- Issue:
- Volume 59:Issue 11(2019)
- Issue Display:
- Volume 59, Issue 11 (2019)
- Year:
- 2019
- Volume:
- 59
- Issue:
- 11
- Issue Sort Value:
- 2019-0059-0011-0000
- Page Start:
- 3525
- Page End:
- 3535
- Publication Date:
- 2019-10-15
- Subjects:
- Hematology -- Periodicals
Blood -- Transfusion -- Periodicals
Blood Group Antigens -- Periodicals
Blood Preservation -- Periodicals
Blood Transfusion -- Periodicals
615 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1537-2995 ↗
http://www.blackwell-synergy.com/member/institutions/issuelist.asp?journal=trf ↗
http://www.transfusion.org ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/trf.15523 ↗
- Languages:
- English
- ISSNs:
- 0041-1132
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 9020.704000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 23266.xml