Cross‐sectional reassessment after 4 years of clinical routine use of AQUIOS CL for absolute T cell quantitation in a university hospital. Issue 5 (19th April 2022)
- Record Type:
- Journal Article
- Title:
- Cross‐sectional reassessment after 4 years of clinical routine use of AQUIOS CL for absolute T cell quantitation in a university hospital. Issue 5 (19th April 2022)
- Main Title:
- Cross‐sectional reassessment after 4 years of clinical routine use of AQUIOS CL for absolute T cell quantitation in a university hospital
- Authors:
- Lemoine, Léa
Malcus, Christophe
Poitevin‐Later, Françoise
Venet, Fabienne
Monneret, Guillaume
Gossez, Morgane - Abstract:
- Abstract: Background: We had previously reported appropriate performances of automated AQUIOS CL cytometer (Beckman Coulter) for regulatory approval of absolute T cell enumeration. However, after 4 years of routine use, we still observed recurrent histogram anomalies that may affect both absolute values and T cell subset percentages results. The objective of the current study was thus to perform a cross‐sectional evaluation of these graphical anomalies within a university hospital context, to assess their influence on results and ultimately to propose a standardized decision tree to circumvent graphical disturbances at the time of results validation. Methods: Eight hundred and sixty‐two blood samples were prospectively analyzed on AQUIOS CL. Results were compared to (i) lymphocyte values from complete blood count; (ii) results from manual staining and analysis on Navios cytometer (Beckman Coulter); (iii) results after washing step and reacquisition on AQUIOS CL. Results: Nearly 75% analyses did not show any graphical anomaly. 20% had single anomaly on "Lymphs (45)" or "Lymphs EV" regions influencing T cells percentages and requiring manual re‐gating of "CD3− capture" region. 5% showed concomitant "Lymphs EV" and "Lymphs (45)" anomalies influencing both T cell percentages and absolute counting and requiring additional staining and analysis on Navios. Finally, <1% presented with anomaly on "CD4/CD8" histogram or "CD3+ All" region, influencing both T cell percentages andAbstract: Background: We had previously reported appropriate performances of automated AQUIOS CL cytometer (Beckman Coulter) for regulatory approval of absolute T cell enumeration. However, after 4 years of routine use, we still observed recurrent histogram anomalies that may affect both absolute values and T cell subset percentages results. The objective of the current study was thus to perform a cross‐sectional evaluation of these graphical anomalies within a university hospital context, to assess their influence on results and ultimately to propose a standardized decision tree to circumvent graphical disturbances at the time of results validation. Methods: Eight hundred and sixty‐two blood samples were prospectively analyzed on AQUIOS CL. Results were compared to (i) lymphocyte values from complete blood count; (ii) results from manual staining and analysis on Navios cytometer (Beckman Coulter); (iii) results after washing step and reacquisition on AQUIOS CL. Results: Nearly 75% analyses did not show any graphical anomaly. 20% had single anomaly on "Lymphs (45)" or "Lymphs EV" regions influencing T cells percentages and requiring manual re‐gating of "CD3− capture" region. 5% showed concomitant "Lymphs EV" and "Lymphs (45)" anomalies influencing both T cell percentages and absolute counting and requiring additional staining and analysis on Navios. Finally, <1% presented with anomaly on "CD4/CD8" histogram or "CD3+ All" region, influencing both T cell percentages and absolute counting. Conclusions: Around 25% AQUIOS CL results were flawed due to gating anomalies. In <5% cases, additional back‐up procedures should be undertaken to ensure results validity. A simple decision‐tree may help in guiding validation process. … (more)
- Is Part Of:
- Cytometry. Volume 102:Issue 5(2022)
- Journal:
- Cytometry
- Issue:
- Volume 102:Issue 5(2022)
- Issue Display:
- Volume 102, Issue 5 (2022)
- Year:
- 2022
- Volume:
- 102
- Issue:
- 5
- Issue Sort Value:
- 2022-0102-0005-0000
- Page Start:
- 390
- Page End:
- 399
- Publication Date:
- 2022-04-19
- Subjects:
- accreditation -- aquios CL -- flow cytometry -- standardization -- T cell
Flow cytometry -- Diagnostic use -- Periodicals
Cytodiagnosis -- Periodicals
616.07582 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/cyto.b.22069 ↗
- Languages:
- English
- ISSNs:
- 1552-4949
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3506.855200
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23225.xml