Comparing a knowledge‐based 3D reconstruction algorithm to TomTec 3D echocardiogram algorithm in measuring left cardiac chamber volumes in the pediatric population. Issue 9 (27th August 2022)
- Record Type:
- Journal Article
- Title:
- Comparing a knowledge‐based 3D reconstruction algorithm to TomTec 3D echocardiogram algorithm in measuring left cardiac chamber volumes in the pediatric population. Issue 9 (27th August 2022)
- Main Title:
- Comparing a knowledge‐based 3D reconstruction algorithm to TomTec 3D echocardiogram algorithm in measuring left cardiac chamber volumes in the pediatric population
- Authors:
- Ahmad, Attila
Shigemitsu, Sachie
Termachi, Yozo
Windram, Jonathan
Khoo, Nee
Colen, Tim
Eckersley, Luke - Abstract:
- Abstract: Background: Three‐dimensional echocardiography (3DE) is an emerging method for volumetric cardiac measurements; however, few vendor‐neutral analysis packages exist. Ventripoint Medical System Plus (VMS3.0+) proprietary software utilizes a validated Magnetic resonance imaging (MRI) database of normal ventricular and atrial morphologies to calculate chamber volumes. This study aimed to compare left ventricular (LV) and atrial (LA) volumes obtained using VMS3.0+ to Tomtec echocardiography analysis software. Methods: Healthy controls ( n = 98) aged 0–18 years were prospectively recruited and 3D DICOM datasets focused on the LV and LA acquired. LV and LA volumes and ejection fractions were measured using TomTec Image Arena 3D LV analysis package and using VMS3.0+. Pearson correlation coefficients, Bland–Altman's plots, and intraclass coefficients (ICC) were calculated, along with analysis time. Results: There was a very good correlation between Ventripoint Medical System (VMS) and Tomtec LV systolic ( r 2 = .88, ICC .89 [95% CI .81, .94]), and diastolic ( r 2 = .88, ICC .90 [95% CI .77, .95]) volumes, and between VMS and Tomtec LA diastolic ( r 2 = .75, ICC .89 [95% CI .81, .93]) and systolic ( r 2 = .88, ICC .91 [95% CI .78, .96]) volumes on linear regression models. Natural log transformations eliminated heteroscedasticity, and power transformations provided the best fit. The time (mins) to analyze volumes using VMS were less than using Tomtec (LV VMS 2.3 ± .5,Abstract: Background: Three‐dimensional echocardiography (3DE) is an emerging method for volumetric cardiac measurements; however, few vendor‐neutral analysis packages exist. Ventripoint Medical System Plus (VMS3.0+) proprietary software utilizes a validated Magnetic resonance imaging (MRI) database of normal ventricular and atrial morphologies to calculate chamber volumes. This study aimed to compare left ventricular (LV) and atrial (LA) volumes obtained using VMS3.0+ to Tomtec echocardiography analysis software. Methods: Healthy controls ( n = 98) aged 0–18 years were prospectively recruited and 3D DICOM datasets focused on the LV and LA acquired. LV and LA volumes and ejection fractions were measured using TomTec Image Arena 3D LV analysis package and using VMS3.0+. Pearson correlation coefficients, Bland–Altman's plots, and intraclass coefficients (ICC) were calculated, along with analysis time. Results: There was a very good correlation between Ventripoint Medical System (VMS) and Tomtec LV systolic ( r 2 = .88, ICC .89 [95% CI .81, .94]), and diastolic ( r 2 = .88, ICC .90 [95% CI .77, .95]) volumes, and between VMS and Tomtec LA diastolic ( r 2 = .75, ICC .89 [95% CI .81, .93]) and systolic ( r 2 = .88, ICC .91 [95% CI .78, .96]) volumes on linear regression models. Natural log transformations eliminated heteroscedasticity, and power transformations provided the best fit. The time (mins) to analyze volumes using VMS were less than using Tomtec (LV VMS 2.3 ± .5, Tomtec 3.3 ± .8, p < .001; LA: VMS 1.9 ± .4, Tomtec 3.4 ± 1.0, p < .001). Conclusions: There was a very good correlation between knowledge‐based (VMS3.0+) and 3D (Tomtec) algorithms when measuring 3D echocardiography‐derived LA and LV volumes in pediatric patients. VMS was slightly faster than Tomtec in analyzing volumetric measurements. … (more)
- Is Part Of:
- Echocardiography. Volume 39:Issue 9(2022)
- Journal:
- Echocardiography
- Issue:
- Volume 39:Issue 9(2022)
- Issue Display:
- Volume 39, Issue 9 (2022)
- Year:
- 2022
- Volume:
- 39
- Issue:
- 9
- Issue Sort Value:
- 2022-0039-0009-0000
- Page Start:
- 1180
- Page End:
- 1189
- Publication Date:
- 2022-08-27
- Subjects:
- 3D echocardiogram -- knowledge‐based 3D reconstruction -- LA function -- LV function -- normal values -- TomTec 4D arena
Echocardiography -- Periodicals
Echocardiography -- Periodicals
616.1207543 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1540-8175 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/echo.15427 ↗
- Languages:
- English
- ISSNs:
- 0742-2822
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3647.572500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File: