Adherence to patient selection criteria in patients undergoing transcatheter aortic valve implantation with the 18F CoreValve ReValving System. Issue 1 (10th September 2009)
- Record Type:
- Journal Article
- Title:
- Adherence to patient selection criteria in patients undergoing transcatheter aortic valve implantation with the 18F CoreValve ReValving System. Issue 1 (10th September 2009)
- Main Title:
- Adherence to patient selection criteria in patients undergoing transcatheter aortic valve implantation with the 18F CoreValve ReValving System
- Authors:
- Piazza, N
Otten, A
Schultz, C
Onuma, Y
Garcia-Garcia, H M
Boersma, E
de Jaegere, P
Serruys, P W - Abstract:
- Abstract : Background: Anecdotal evidence suggests that transcatheter aortic valve implantation (TAVI) is being used beyond pre-market label indications. Methods: To assess the frequency and outcomes associated with "off-label" use of TAVI, we conducted a retrospective study, examining adherence to patient selection criteria in 63 patients undergoing implantation with the 18F CoreValve ReValving System (CRS). Label status (on-label vs off-label) was determined by following (1) inclusion/exclusion criteria indicated in the 18F CRS safety and efficacy trial and (2) a patient selection matrix indicating anatomical boundaries to guide patient selection. Off-label use was defined as the presence of at least one exclusion criterion or "non-acceptable" criteria based on the patient selection matrix. Results: Off-label implantation was identified in 42 patients (67%)—40% had one, 19% had two and 8% had three or more off-label criteria. Baseline demographics were similar between the groups except for a higher logistic EuroSCORE in the on-label group (19.8 (11.2) vs 14.5 (7.3), p = 0.029). There was no significant difference in the procedural success rates between the on-label and off-label groups (91% vs 95%, respectively, p = 0.47). The frequency of angiographic moderate-severe aortic regurgitation, post-implant dilatation or implantation of a second valve was also similar between the groups. At 30 days, the cumulative death rate was 10%; there were four deaths in the "on-label" andAbstract : Background: Anecdotal evidence suggests that transcatheter aortic valve implantation (TAVI) is being used beyond pre-market label indications. Methods: To assess the frequency and outcomes associated with "off-label" use of TAVI, we conducted a retrospective study, examining adherence to patient selection criteria in 63 patients undergoing implantation with the 18F CoreValve ReValving System (CRS). Label status (on-label vs off-label) was determined by following (1) inclusion/exclusion criteria indicated in the 18F CRS safety and efficacy trial and (2) a patient selection matrix indicating anatomical boundaries to guide patient selection. Off-label use was defined as the presence of at least one exclusion criterion or "non-acceptable" criteria based on the patient selection matrix. Results: Off-label implantation was identified in 42 patients (67%)—40% had one, 19% had two and 8% had three or more off-label criteria. Baseline demographics were similar between the groups except for a higher logistic EuroSCORE in the on-label group (19.8 (11.2) vs 14.5 (7.3), p = 0.029). There was no significant difference in the procedural success rates between the on-label and off-label groups (91% vs 95%, respectively, p = 0.47). The frequency of angiographic moderate-severe aortic regurgitation, post-implant dilatation or implantation of a second valve was also similar between the groups. At 30 days, the cumulative death rate was 10%; there were four deaths in the "on-label" and three deaths in the "off-label" group. Conclusion: In this study we found that "off-label" implantation of the CRS was common. Further studies are needed to evaluate the consequences of "label status" for patients undergoing TAVI. … (more)
- Is Part Of:
- Heart. Volume 96:Issue 1(2010)
- Journal:
- Heart
- Issue:
- Volume 96:Issue 1(2010)
- Issue Display:
- Volume 96, Issue 1 (2010)
- Year:
- 2010
- Volume:
- 96
- Issue:
- 1
- Issue Sort Value:
- 2010-0096-0001-0000
- Page Start:
- 19
- Page End:
- 26
- Publication Date:
- 2009-09-10
- Subjects:
- Heart -- Diseases -- Treatment -- Periodicals
Cardiology -- Periodicals
616.12 - Journal URLs:
- http://www.bmj.com/archive ↗
http://heart.bmj.com ↗
http://www.heartjnl.com ↗ - DOI:
- 10.1136/hrt.2009.172809 ↗
- Languages:
- English
- ISSNs:
- 1355-6037
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23179.xml