Learning from scanners: Bias reduction and feature correction in radiomics. (November 2019)
- Record Type:
- Journal Article
- Title:
- Learning from scanners: Bias reduction and feature correction in radiomics. (November 2019)
- Main Title:
- Learning from scanners: Bias reduction and feature correction in radiomics
- Authors:
- Zhovannik, Ivan
Bussink, Johan
Traverso, Alberto
Shi, Zhenwei
Kalendralis, Petros
Wee, Leonard
Dekker, Andre
Fijten, Rianne
Monshouwer, René - Abstract:
- Highlights: Typically encountered CT exposure variations result in radiomics values distortion. Proposed correction method suppresses the non-tumor related variation in radiomics. The clinical relevance was shown using a 221 lung cancer patient cohort. Abstract: Purpose: Radiomics are quantitative features extracted from medical images. Many radiomic features depend not only on tumor properties, but also on non-tumor related factors such as scanner signal-to-noise ratio (SNR), reconstruction kernel and other image acquisition settings. This causes undesirable value variations in the features and reduces the performance of prediction models. In this paper, we investigate whether we can use phantom measurements to characterize and correct for the scanner SNR dependence. Methods: We used a phantom with 17 regions of interest (ROI) to investigate the influence of different SNR values. CT scans were acquired with 9 different exposure settings. We developed an additive correction model to reduce scanner SNR influence. Results: Sixty-two of 92 radiomic features showed high variance due to the scanner SNR. Of these 62 features, 47 showed at least a factor 2 significant standard deviation reduction by using the additive correction model. We assessed the clinical relevance of radiomics instability by using a 221 NSCLC patient cohort measured with the same scanner. Conclusions: Phantom measurements show that roughly two third of the radiomic features depend on the exposure setting ofHighlights: Typically encountered CT exposure variations result in radiomics values distortion. Proposed correction method suppresses the non-tumor related variation in radiomics. The clinical relevance was shown using a 221 lung cancer patient cohort. Abstract: Purpose: Radiomics are quantitative features extracted from medical images. Many radiomic features depend not only on tumor properties, but also on non-tumor related factors such as scanner signal-to-noise ratio (SNR), reconstruction kernel and other image acquisition settings. This causes undesirable value variations in the features and reduces the performance of prediction models. In this paper, we investigate whether we can use phantom measurements to characterize and correct for the scanner SNR dependence. Methods: We used a phantom with 17 regions of interest (ROI) to investigate the influence of different SNR values. CT scans were acquired with 9 different exposure settings. We developed an additive correction model to reduce scanner SNR influence. Results: Sixty-two of 92 radiomic features showed high variance due to the scanner SNR. Of these 62 features, 47 showed at least a factor 2 significant standard deviation reduction by using the additive correction model. We assessed the clinical relevance of radiomics instability by using a 221 NSCLC patient cohort measured with the same scanner. Conclusions: Phantom measurements show that roughly two third of the radiomic features depend on the exposure setting of the scanner. The dependence can be modeled and corrected significantly reducing the variation in feature values with at least a factor of 2. More complex models will likely increase the correctability. Scanner SNR correction will result in more reliable radiomics predictions in NSCLC. … (more)
- Is Part Of:
- Clinical and translational radiation oncology. Volume 19(2019)
- Journal:
- Clinical and translational radiation oncology
- Issue:
- Volume 19(2019)
- Issue Display:
- Volume 19, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 19
- Issue:
- 2019
- Issue Sort Value:
- 2019-0019-2019-0000
- Page Start:
- 33
- Page End:
- 38
- Publication Date:
- 2019-11
- Subjects:
- Radiomics -- Reproducibility -- Predictive modeling -- Phantoms
Cancer -- Radiotherapy -- Periodicals
Oncology -- Periodicals
Cancer -- Radiotherapy
Oncology
Radiation Oncology
Neoplasms -- radiotherapy
Translational Medical Research
Periodicals
Electronic journals
Periodicals
616.9940642 - Journal URLs:
- https://www.journals.elsevier.com/clinical-and-translational-radiation-oncology ↗
http://www.sciencedirect.com/science/journal/24056308 ↗
http://www.sciencedirect.com/ ↗ - DOI:
- 10.1016/j.ctro.2019.07.003 ↗
- Languages:
- English
- ISSNs:
- 2405-6308
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23178.xml