Investigation of multiple whole smoke dosimetry techniques using a VITROCELL®VC10® smoke exposure system. (2019)
- Record Type:
- Journal Article
- Title:
- Investigation of multiple whole smoke dosimetry techniques using a VITROCELL®VC10® smoke exposure system. (2019)
- Main Title:
- Investigation of multiple whole smoke dosimetry techniques using a VITROCELL®VC10® smoke exposure system
- Authors:
- Keyser, Brian M.
Leverette, Robert
Hollings, Michael
Seymour, Adam
Reeve, Lesley
Fields, Wanda - Abstract:
- Graphical abstract: Highlights: Investigation of dose-determining methods using the Vitrocell® VC10® system. Dose assessment using Quartz Crystal Microbalances (QCM) and aerosol photometers. Dose assessment using fluorescence of DMSO-captured smoke constituents. QCM, photometer AUC, and DMSO-captured matter were consistent and reproducible. Abstract: The Vitrocell® VC10® smoke exposure system offers multiple platforms for air liquid interface (ALI) and air agar interface (AAI) exposure that mimic in vivo conditions for assessing toxicological impact of whole smoke using in vitro assays. The aim of this study was to investigate and compare multiple dosimetry techniques that may be employed during combustible cigarette whole smoke exposure using the Vitrocell® VC10® smoking robot. The following techniques were assessed: (1) quartz crystal microbalances (QCMs), (2) aerosol photometers (using area under curve, AUC), and (3) fluorescence of anhydrous dimethyl sulfoxide (DMSO)-captured smoke constituents. Results showed that each of the dosimetry techniques was able to distinguish different levels of whole smoke airflow in a concentration-related manner. When compared to each other, the three techniques showed a high level of consistency and all were considered efficient tools in quantifying dose during an exposure, although higher variation was observed at the higher airflows tested. Overall, the dosimetry tools investigated here provide effective measures of the whole smokeGraphical abstract: Highlights: Investigation of dose-determining methods using the Vitrocell® VC10® system. Dose assessment using Quartz Crystal Microbalances (QCM) and aerosol photometers. Dose assessment using fluorescence of DMSO-captured smoke constituents. QCM, photometer AUC, and DMSO-captured matter were consistent and reproducible. Abstract: The Vitrocell® VC10® smoke exposure system offers multiple platforms for air liquid interface (ALI) and air agar interface (AAI) exposure that mimic in vivo conditions for assessing toxicological impact of whole smoke using in vitro assays. The aim of this study was to investigate and compare multiple dosimetry techniques that may be employed during combustible cigarette whole smoke exposure using the Vitrocell® VC10® smoking robot. The following techniques were assessed: (1) quartz crystal microbalances (QCMs), (2) aerosol photometers (using area under curve, AUC), and (3) fluorescence of anhydrous dimethyl sulfoxide (DMSO)-captured smoke constituents. Results showed that each of the dosimetry techniques was able to distinguish different levels of whole smoke airflow in a concentration-related manner. When compared to each other, the three techniques showed a high level of consistency and all were considered efficient tools in quantifying dose during an exposure, although higher variation was observed at the higher airflows tested. Overall, the dosimetry tools investigated here provide effective measures of the whole smoke concentrations tested during the exposure. … (more)
- Is Part Of:
- Toxicology reports. Volume 6(2019)
- Journal:
- Toxicology reports
- Issue:
- Volume 6(2019)
- Issue Display:
- Volume 6, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 6
- Issue:
- 2019
- Issue Sort Value:
- 2019-0006-2019-0000
- Page Start:
- 1281
- Page End:
- 1288
- Publication Date:
- 2019
- Subjects:
- Whole smoke -- Smoke exposure system -- Dosimetry -- Aerosol -- Photometers
Toxicology -- Periodicals
Clinical toxicology -- Periodicals
Drug-Related Side Effects and Adverse Reactions
Hazardous Substances
Poisoning
Toxicology
Electronic journals
Periodicals
Periodicals
571.9505 - Journal URLs:
- http://www.sciencedirect.com/science/journal/22147500 ↗
http://www.journals.elsevier.com/toxicology-reports ↗
http://www.sciencedirect.com/ ↗ - DOI:
- 10.1016/j.toxrep.2019.10.011 ↗
- Languages:
- English
- ISSNs:
- 2214-7500
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23143.xml