Model-based tracking of the bones of the foot: A biplane fluoroscopy validation study. (1st January 2018)
- Record Type:
- Journal Article
- Title:
- Model-based tracking of the bones of the foot: A biplane fluoroscopy validation study. (1st January 2018)
- Main Title:
- Model-based tracking of the bones of the foot: A biplane fluoroscopy validation study
- Authors:
- Iaquinto, Joseph M.
Kindig, Matthew W.
Haynor, David R.
Vu, QuocBao
Pepin, Nathan
Tsai, Richard
Sangeorzan, Bruce J.
Ledoux, William R. - Abstract:
- Abstract: Measuring foot kinematics using optical motion capture is technically challenging due to the depth of the talus, small bone size, and soft tissue artifact. We present a validation of our biplane X-ray system, demonstrating its accuracy in tracking the foot bones directly. Using an experimental linear/rotary stage we imaged pairs of tali, calcanei, and first metatarsals, with embedded beads, through 30 poses. Model- and bead-based algorithms were employed for semi-automatic tracking. Translational and rotational poses were compared to the experimental stage (a reference standard) to determine registration performance. For each bone, 10 frames per pose were analyzed. Model-based: The resulting overall translational bias of the six bones was 0.058 mm with a precision of ± 0.049 mm. The overall rotational bias of the six bones was 0.42° with a precision of ± 0.41°. Bead-based: the overall translational bias was 0.037 mm with a precision of ± 0.032 mm and for rotation was 0.29° with a precision of ± 0.26°. We validated the accuracy of our system to determine the spatial position and orientation of isolated foot bones, including the talus, calcaneus, and first metatarsal over a range of quasi-static poses. Although the accuracy of dynamic motion was not assessed, use of an experimental stage establishes a reference standard. Highlights: A model-based bone tracking algorithm is validated for foot and ankle bones. The translational accuracy of the system was 0.058 mm withAbstract: Measuring foot kinematics using optical motion capture is technically challenging due to the depth of the talus, small bone size, and soft tissue artifact. We present a validation of our biplane X-ray system, demonstrating its accuracy in tracking the foot bones directly. Using an experimental linear/rotary stage we imaged pairs of tali, calcanei, and first metatarsals, with embedded beads, through 30 poses. Model- and bead-based algorithms were employed for semi-automatic tracking. Translational and rotational poses were compared to the experimental stage (a reference standard) to determine registration performance. For each bone, 10 frames per pose were analyzed. Model-based: The resulting overall translational bias of the six bones was 0.058 mm with a precision of ± 0.049 mm. The overall rotational bias of the six bones was 0.42° with a precision of ± 0.41°. Bead-based: the overall translational bias was 0.037 mm with a precision of ± 0.032 mm and for rotation was 0.29° with a precision of ± 0.26°. We validated the accuracy of our system to determine the spatial position and orientation of isolated foot bones, including the talus, calcaneus, and first metatarsal over a range of quasi-static poses. Although the accuracy of dynamic motion was not assessed, use of an experimental stage establishes a reference standard. Highlights: A model-based bone tracking algorithm is validated for foot and ankle bones. The translational accuracy of the system was 0.058 mm with a precision of ±0.049 mm. The rotational accuracy of the system was 0.42° with a precision of ±0.41°. Comparable bead-tracking errors support the use of precision stages in validation. … (more)
- Is Part Of:
- Computers in biology and medicine. Volume 92(2018)
- Journal:
- Computers in biology and medicine
- Issue:
- Volume 92(2018)
- Issue Display:
- Volume 92, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 92
- Issue:
- 2018
- Issue Sort Value:
- 2018-0092-2018-0000
- Page Start:
- 118
- Page End:
- 127
- Publication Date:
- 2018-01-01
- Subjects:
- Biplane fluoroscopy -- Model-based -- Bone-based -- Validation -- Foot and ankle
Medicine -- Data processing -- Periodicals
Biology -- Data processing -- Periodicals
610.285 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00104825/ ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.compbiomed.2017.11.006 ↗
- Languages:
- English
- ISSNs:
- 0010-4825
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3394.880000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23160.xml