Demagnetization fault detection by a novel and flexible modeling method for outer rotor permanent magnet synchronous machine. (March 2020)
- Record Type:
- Journal Article
- Title:
- Demagnetization fault detection by a novel and flexible modeling method for outer rotor permanent magnet synchronous machine. (March 2020)
- Main Title:
- Demagnetization fault detection by a novel and flexible modeling method for outer rotor permanent magnet synchronous machine
- Authors:
- Sharouni, Sahar
Naderi, Peyman
Hedayati, Mahdi
Hajihosseini, Payman - Abstract:
- Highlights: An original Magnetic Equivalent Circuit (MEC) method is presented for Outer Rotor Permanent Magnet Synchronous Machine for first time. The model accuracy can be tuned by some selectable parameters in the model. Demagnetization fault diagnosis method is presented for first time for the above-mentioned machine. Saturation effect is modeled by a novel method, therefore all of the space and time harmonics are considered in the presented model. Very shorter processing time during is obtained compared to FEM. Therefore, the presented method is a suitable choice for electric machines modeling. Abstract: The research presents a novel technique for modeling of Outer Rotor Permanent Magnet Synchronous Machines (OR-PMSMs) in healthy and faulty cases with demagnetization fault based on an improved Magnetic Equivalent Circuit (MEC) method. Saturation effect is considered by a new method, where the B-H curve fitting is performed by using a novel nonlinear function. The machine properties such as the number of poles, number of slots, magnets size and all of the other parameters can be selected arbitrarily in the proposed model. Noticing to machine structure, the machine geometry is divided into 11 individual zones. Each of the flux tubes in the core is modeled by a nonlinear reluctance and the machine performances in both transient and steady-state conditions are studied. Various machine properties such as magnets arc, winding configuration, and slot skewing angle are analyzedHighlights: An original Magnetic Equivalent Circuit (MEC) method is presented for Outer Rotor Permanent Magnet Synchronous Machine for first time. The model accuracy can be tuned by some selectable parameters in the model. Demagnetization fault diagnosis method is presented for first time for the above-mentioned machine. Saturation effect is modeled by a novel method, therefore all of the space and time harmonics are considered in the presented model. Very shorter processing time during is obtained compared to FEM. Therefore, the presented method is a suitable choice for electric machines modeling. Abstract: The research presents a novel technique for modeling of Outer Rotor Permanent Magnet Synchronous Machines (OR-PMSMs) in healthy and faulty cases with demagnetization fault based on an improved Magnetic Equivalent Circuit (MEC) method. Saturation effect is considered by a new method, where the B-H curve fitting is performed by using a novel nonlinear function. The machine properties such as the number of poles, number of slots, magnets size and all of the other parameters can be selected arbitrarily in the proposed model. Noticing to machine structure, the machine geometry is divided into 11 individual zones. Each of the flux tubes in the core is modeled by a nonlinear reluctance and the machine performances in both transient and steady-state conditions are studied. Various machine properties such as magnets arc, winding configuration, and slot skewing angle are analyzed and the dynamic behaviour is compared in various cases. Comparison with Finite-Element-Method (FEM) shows the effectiveness and accuracy of the proposed MEC method and much shorter processing time compared to FEM. … (more)
- Is Part Of:
- International journal of electrical power & energy systems. Volume 116(2020)
- Journal:
- International journal of electrical power & energy systems
- Issue:
- Volume 116(2020)
- Issue Display:
- Volume 116, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 116
- Issue:
- 2020
- Issue Sort Value:
- 2020-0116-2020-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-03
- Subjects:
- Current signature analysis -- Demagnetization fault -- Magnetic Equivalent Circuit (MEC) -- Outer Rotor Permanent Magnet Synchronous Machine (OR-PMSM) -- Saturation effect
Electrical engineering -- Periodicals
Electric power systems -- Periodicals
Électrotechnique -- Périodiques
Réseaux électriques (Énergie) -- Périodiques
Electric power systems
Electrical engineering
Periodicals
621.3 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01420615 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ijepes.2019.105539 ↗
- Languages:
- English
- ISSNs:
- 0142-0615
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.220000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23157.xml