Accurate dose measurements using Cherenkov emission polarization imaging. Issue 8 (10th May 2022)
- Record Type:
- Journal Article
- Title:
- Accurate dose measurements using Cherenkov emission polarization imaging. Issue 8 (10th May 2022)
- Main Title:
- Accurate dose measurements using Cherenkov emission polarization imaging
- Authors:
- Cloutier, Émily
Archambault, Louis
Beaulieu, Luc - Abstract:
- Abstract: Purpose: Cherenkov radiation carries the potential of direct in‐water dose measurements, but its precision is currently limited by a strong anisotropy. Taking advantage of polarization imaging, this work proposes a new approach for high‐accuracy Cherenkov emission dose measurements. Methods: Cherenkov radiation produced in a 15 × 15 × 20‐cm 3 water tank is imaged with a cooled charge‐coupled device (CCD) camera from four polarizer transmission axes [0, 45, 90, 135°]. The water tank is positioned at the isocenter of a 5 × 5‐cm 2, 6‐, and 18‐MV photon beam. Using Malus' law, the polarized portion of the signal is extracted. Corrections are applied to the polarized signal following azimuthal and polar Cherenkov emission angular distributions extracted from Monte Carlo simulations. Projected percent depth dose and beam profiles are measured and compared with the prediction from a treatment planning system (TPS). Results: Corrected polarized signals on the central axis reduced deviations at depth (mean ± standard deviation) from 8% ± 5% to 0.8% ± 1% at 6 MV and 8% ± 7% to 1% ± 3% at 18 MV. For the profile measurement, differences between the corrected polarized signal and the TPS calculations are 1% ± 3% and 2% ± 3% on the central axis at 6 and 18 MV respectively. In these conditions, Cherenkov emission is shown to be partly polarized. Conclusions: This work proposes a novel polarization imaging approach enabling high‐precision water‐based dose measurements using theAbstract: Purpose: Cherenkov radiation carries the potential of direct in‐water dose measurements, but its precision is currently limited by a strong anisotropy. Taking advantage of polarization imaging, this work proposes a new approach for high‐accuracy Cherenkov emission dose measurements. Methods: Cherenkov radiation produced in a 15 × 15 × 20‐cm 3 water tank is imaged with a cooled charge‐coupled device (CCD) camera from four polarizer transmission axes [0, 45, 90, 135°]. The water tank is positioned at the isocenter of a 5 × 5‐cm 2, 6‐, and 18‐MV photon beam. Using Malus' law, the polarized portion of the signal is extracted. Corrections are applied to the polarized signal following azimuthal and polar Cherenkov emission angular distributions extracted from Monte Carlo simulations. Projected percent depth dose and beam profiles are measured and compared with the prediction from a treatment planning system (TPS). Results: Corrected polarized signals on the central axis reduced deviations at depth (mean ± standard deviation) from 8% ± 5% to 0.8% ± 1% at 6 MV and 8% ± 7% to 1% ± 3% at 18 MV. For the profile measurement, differences between the corrected polarized signal and the TPS calculations are 1% ± 3% and 2% ± 3% on the central axis at 6 and 18 MV respectively. In these conditions, Cherenkov emission is shown to be partly polarized. Conclusions: This work proposes a novel polarization imaging approach enabling high‐precision water‐based dose measurements using the Cherenkov radiation. The method allows a correction of the Cherenkov emission anisotropy within 4% on the beam central axis and in depth. … (more)
- Is Part Of:
- Medical physics. Volume 49:Issue 8(2022)
- Journal:
- Medical physics
- Issue:
- Volume 49:Issue 8(2022)
- Issue Display:
- Volume 49, Issue 8 (2022)
- Year:
- 2022
- Volume:
- 49
- Issue:
- 8
- Issue Sort Value:
- 2022-0049-0008-0000
- Page Start:
- 5417
- Page End:
- 5422
- Publication Date:
- 2022-05-10
- Subjects:
- Cherenkov -- imaging -- luminescence -- polarization
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.15693 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23152.xml