A computational fluid dynamics analysis of a patient with acute non-A-non-B aortic dissection after type I hybrid arch repair. (March 2020)
- Record Type:
- Journal Article
- Title:
- A computational fluid dynamics analysis of a patient with acute non-A-non-B aortic dissection after type I hybrid arch repair. (March 2020)
- Main Title:
- A computational fluid dynamics analysis of a patient with acute non-A-non-B aortic dissection after type I hybrid arch repair
- Authors:
- Xiong, Zhuxiang
Yang, Peng
Li, Da
Qiu, Yue
Zheng, Tinghui
Hu, Jia - Abstract:
- Highlights: Type I hybrid arch repair is an effective treatment option for non-A-non-B aortic dissection. The short-term outcome of this particular patient is satisfactory after hybrid arch repair. The hemodynamic parameters become normal after hybrid arch repair. Abstract: The clinical presentation and natural courses in acute non-A-non-B aortic dissection (AD) are quite different from classical acute type A or type B AD, and the benefit of hybrid technique for this clinical scenario has not been validated. By using computational fluid dynamics (CFD) analysis, we aim to investigate a series of hemodynamic-related changes in aortic morphology in a patient who underwent type I hybrid arch repair (HAR). Computed tomographic angiographies (preoperative, one week, one month and one year after HAR) of a 52-year old male patient with arch-entry type acute non-A-non-B dissection were collected. Three-dimensional models were reconstructed by using an image processing package Mimics (materialize). Morphological and hemodynamic parameters of aorta and its branch vessels were analysed. Post-operatively, the false lumen index (FLI) gradually decreased from 2.02 to 0.38 and the curvature of the aortic arch was also reduced. However, the aortic arch lengthened and the diameter of the distal abdominal aorta expanded. In addition, the blood flow gradually became organised and the pressure in the true lumen (TL) increased over time and eventually approximated the pressure in the false lumenHighlights: Type I hybrid arch repair is an effective treatment option for non-A-non-B aortic dissection. The short-term outcome of this particular patient is satisfactory after hybrid arch repair. The hemodynamic parameters become normal after hybrid arch repair. Abstract: The clinical presentation and natural courses in acute non-A-non-B aortic dissection (AD) are quite different from classical acute type A or type B AD, and the benefit of hybrid technique for this clinical scenario has not been validated. By using computational fluid dynamics (CFD) analysis, we aim to investigate a series of hemodynamic-related changes in aortic morphology in a patient who underwent type I hybrid arch repair (HAR). Computed tomographic angiographies (preoperative, one week, one month and one year after HAR) of a 52-year old male patient with arch-entry type acute non-A-non-B dissection were collected. Three-dimensional models were reconstructed by using an image processing package Mimics (materialize). Morphological and hemodynamic parameters of aorta and its branch vessels were analysed. Post-operatively, the false lumen index (FLI) gradually decreased from 2.02 to 0.38 and the curvature of the aortic arch was also reduced. However, the aortic arch lengthened and the diameter of the distal abdominal aorta expanded. In addition, the blood flow gradually became organised and the pressure in the true lumen (TL) increased over time and eventually approximated the pressure in the false lumen (FL). Moreover, the region of the abnormal wall shear stress (WSS) in the TL progressively decreased while the WSS in most areas of the FL remained below 4 dyne/cm 2 . The blood supply to most of the aortic branches returned to normal at the one-year follow-up. Type I HAR is an effective procedure for patients with acute non-A-non-B aortic dissection in terms of restoring normal blood flow in TL and facilitating positive remodeling of distal aorta. Long-term surveillance and follow-up is mandatory. … (more)
- Is Part Of:
- Medical engineering & physics. Volume 77(2020)
- Journal:
- Medical engineering & physics
- Issue:
- Volume 77(2020)
- Issue Display:
- Volume 77, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 77
- Issue:
- 2020
- Issue Sort Value:
- 2020-0077-2020-0000
- Page Start:
- 43
- Page End:
- 52
- Publication Date:
- 2020-03
- Subjects:
- Non-A-non-B aortic dissection -- Hybrid arch repair (HAR) -- Morphology -- Computational fluid dynamics (CFD) -- Hemodynamic
Biomedical engineering -- Periodicals
Biomedical Engineering -- Periodicals
Physics -- Periodicals
Génie biomédical -- Périodiques
Biomedical engineering
Electronic journals
Periodicals
610.28 - Journal URLs:
- http://www.medengphys.com ↗
http://www.sciencedirect.com/science/journal/13504533 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/13504533 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/13504533 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.medengphy.2019.10.019 ↗
- Languages:
- English
- ISSNs:
- 1350-4533
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5527.323000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23145.xml