Secondhand smoke levels in public building main entrances: outdoor and indoor PM2.5 assessment. Issue 6 (28th September 2011)
- Record Type:
- Journal Article
- Title:
- Secondhand smoke levels in public building main entrances: outdoor and indoor PM2.5 assessment. Issue 6 (28th September 2011)
- Main Title:
- Secondhand smoke levels in public building main entrances: outdoor and indoor PM2.5 assessment
- Authors:
- Sureda, Xisca
Martínez-Sánchez, Jose M
López, María José
Fu, Marcela
Agüero, Fernando
Saltó, Esteve
Nebot, Manel
Fernández, Esteve - Abstract:
- Abstract : Background/Objectives: To describe secondhand smoke (SHS) levels in halls and main entrances (outdoors) in different buildings by measurement of PM2.5 and airborne nicotine. Methods: Cross-sectional study in a sample of 47 public buildings. The authors studied SHS levels derived from PM2.5 (micrograms per cubic metre) using TSI SidePak Personal Aerosol Monitors. The authors tested four locations within buildings: hall, main entrance (outdoor), control (indoor) and control (outdoor). The authors also measured airborne nicotine concentration (micrograms per cubic metre) in main entrances (outdoor). The authors computed medians and IQRs to describe the data. Spearman correlation coefficient (rsp) was used to explore the association between PM2.5 concentrations simultaneously measured in halls and main entrances as well as between PM2.5 and nicotine concentrations. Results: The authors obtained an overall median PM2.5 concentration of hall 18.20 μg/m 3 (IQR: 10.92–23.92 μg/m 3 ), main entrance (outdoor) 17.16 μg/m 3 (IQR: 10.92–24.96 μg/m 3 ), control (indoor) 10.40 μg/m 3 (IQR: 6.76–15.60 μg/m 3 ) and control (outdoor) 13.00 μg/m 3 (IQR: 8.32–18.72 μg/m 3 ). The PM2.5 concentration in halls was more correlated with concentration in the main entrances (outdoors) (rsp=0.518, 95% CI 0.271 to 0.701) than with the control indoor (rsp=0.316, 95% CI 0.032 to 0.553). The Spearman correlation coefficient between nicotine and PM2.5 concentration was 0.365 (95% CI −0.009 toAbstract : Background/Objectives: To describe secondhand smoke (SHS) levels in halls and main entrances (outdoors) in different buildings by measurement of PM2.5 and airborne nicotine. Methods: Cross-sectional study in a sample of 47 public buildings. The authors studied SHS levels derived from PM2.5 (micrograms per cubic metre) using TSI SidePak Personal Aerosol Monitors. The authors tested four locations within buildings: hall, main entrance (outdoor), control (indoor) and control (outdoor). The authors also measured airborne nicotine concentration (micrograms per cubic metre) in main entrances (outdoor). The authors computed medians and IQRs to describe the data. Spearman correlation coefficient (rsp) was used to explore the association between PM2.5 concentrations simultaneously measured in halls and main entrances as well as between PM2.5 and nicotine concentrations. Results: The authors obtained an overall median PM2.5 concentration of hall 18.20 μg/m 3 (IQR: 10.92–23.92 μg/m 3 ), main entrance (outdoor) 17.16 μg/m 3 (IQR: 10.92–24.96 μg/m 3 ), control (indoor) 10.40 μg/m 3 (IQR: 6.76–15.60 μg/m 3 ) and control (outdoor) 13.00 μg/m 3 (IQR: 8.32–18.72 μg/m 3 ). The PM2.5 concentration in halls was more correlated with concentration in the main entrances (outdoors) (rsp=0.518, 95% CI 0.271 to 0.701) than with the control indoor (rsp=0.316, 95% CI 0.032 to 0.553). The Spearman correlation coefficient between nicotine and PM2.5 concentration was 0.365 (95% CI −0.009 to 0.650). Conclusions: Indoor locations where smoking is banned are not completely free from SHS with levels similar to those obtained in the immediate entrances (outdoors) where smoking is allowed, indicating that SHS from outdoors settings drifts to adjacent indoors. These results warrant a revision of current smoke-free policies in particular outdoor settings. … (more)
- Is Part Of:
- Tobacco control. Volume 21:Issue 6(2012)
- Journal:
- Tobacco control
- Issue:
- Volume 21:Issue 6(2012)
- Issue Display:
- Volume 21, Issue 6 (2012)
- Year:
- 2012
- Volume:
- 21
- Issue:
- 6
- Issue Sort Value:
- 2012-0021-0006-0000
- Page Start:
- 543
- Page End:
- 548
- Publication Date:
- 2011-09-28
- Subjects:
- Secondhand smoke -- particulate matter -- tobacco smoke pollution -- outdoor tobacco smoke -- airborne nicotine -- prevention -- public policy -- environment -- surveillance and monitoring -- primary healthcare -- environmental tobacco smoke -- smoking-caused disease -- prevalence -- cessation
Tobacco use -- Prevention -- Periodicals
Tobacco use -- Periodicals
Smoking -- Law and legislation -- Periodicals
Smoking -- prevention & control -- Periodicals
Tobacco Use Disorder -- prevention & control -- Periodicals
Tobacco -- Periodicals
Electronic journals
613.85 - Journal URLs:
- http://tc.bmjjournals.com/ ↗
http://www.jstor.org/journals/09644563.html ↗
http://www.ncbi.nlm.nih.gov/pmc/journals/180/ ↗
http://www.bmj.com/archive ↗ - DOI:
- 10.1136/tobaccocontrol-2011-050040 ↗
- Languages:
- English
- ISSNs:
- 0964-4563
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23144.xml