Airborne Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) in Hospitals: Effects of Aerosol-Generating Procedures, HEPA-Filtration Units, Patient Viral Load, and Physical Distance. (28th February 2022)
- Record Type:
- Journal Article
- Title:
- Airborne Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) in Hospitals: Effects of Aerosol-Generating Procedures, HEPA-Filtration Units, Patient Viral Load, and Physical Distance. (28th February 2022)
- Main Title:
- Airborne Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) in Hospitals: Effects of Aerosol-Generating Procedures, HEPA-Filtration Units, Patient Viral Load, and Physical Distance
- Authors:
- Thuresson, Sara
Fraenkel, Carl Johan
Sasinovich, Sviataslau
Soldemyr, Jonathan
Widell, Anders
Medstrand, Patrik
Alsved, Malin
Löndahl, Jakob - Abstract:
- Abstract: Background: Transmission of coronavirus disease 2019 (COVID-19) can occur through inhalation of fine droplets or aerosols containing infectious virus. The objective of this study was to identify situations, patient characteristics, environmental parameters, and aerosol-generating procedures (AGPs) associated with airborne severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) virus. Methods: Air samples were collected near hospitalized COVID-19 patients and analyzed by RT-qPCR. Results were related to distance to the patient, most recent patient diagnostic PCR cycle threshold (Ct) value, room ventilation, and ongoing potential AGPs. Results: In total, 310 air samples were collected; of these, 26 (8%) were positive for SARS-CoV-2. Of the 231 samples from patient rooms, 22 (10%) were positive for SARS-CoV-2. Positive air samples were associated with a low patient Ct value (OR, 5.0 for Ct <25 vs >25; P = .01; 95% CI: 1.18–29.5) and a shorter physical distance to the patient (OR, 2.0 for every meter closer to the patient; P = .05; 95% CI: 1.0–3.8). A mobile HEPA-filtration unit in the room decreased the proportion of positive samples (OR, .3; P = .02; 95% CI: .12–.98). No association was observed between SARS-CoV-2–positive air samples and mechanical ventilation, high-flow nasal cannula, nebulizer treatment, or noninvasive ventilation. An association was found with positive expiratory pressure training ( P < .01) and a trend towards an association for airwayAbstract: Background: Transmission of coronavirus disease 2019 (COVID-19) can occur through inhalation of fine droplets or aerosols containing infectious virus. The objective of this study was to identify situations, patient characteristics, environmental parameters, and aerosol-generating procedures (AGPs) associated with airborne severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) virus. Methods: Air samples were collected near hospitalized COVID-19 patients and analyzed by RT-qPCR. Results were related to distance to the patient, most recent patient diagnostic PCR cycle threshold (Ct) value, room ventilation, and ongoing potential AGPs. Results: In total, 310 air samples were collected; of these, 26 (8%) were positive for SARS-CoV-2. Of the 231 samples from patient rooms, 22 (10%) were positive for SARS-CoV-2. Positive air samples were associated with a low patient Ct value (OR, 5.0 for Ct <25 vs >25; P = .01; 95% CI: 1.18–29.5) and a shorter physical distance to the patient (OR, 2.0 for every meter closer to the patient; P = .05; 95% CI: 1.0–3.8). A mobile HEPA-filtration unit in the room decreased the proportion of positive samples (OR, .3; P = .02; 95% CI: .12–.98). No association was observed between SARS-CoV-2–positive air samples and mechanical ventilation, high-flow nasal cannula, nebulizer treatment, or noninvasive ventilation. An association was found with positive expiratory pressure training ( P < .01) and a trend towards an association for airway manipulation, including bronchoscopies and in- and extubations. Conclusions: Our results show that major risk factors for airborne SARS-CoV-2 include short physical distance, high patient viral load, and poor room ventilation. AGPs, as traditionally defined, seem to be of secondary importance. Abstract : Healthcare infection-control guidelines emphasize breathing protection during aerosol-generating procedures with COVID-19 patients. Our study suggests that SARS-CoV-2 in air is mainly determined by distance, patient viral load, and room ventilation. We found weak support for emissions during aerosol-generating procedures. … (more)
- Is Part Of:
- Clinical infectious diseases. Volume 75:Number 1(2022)
- Journal:
- Clinical infectious diseases
- Issue:
- Volume 75:Number 1(2022)
- Issue Display:
- Volume 75, Issue 1 (2022)
- Year:
- 2022
- Volume:
- 75
- Issue:
- 1
- Issue Sort Value:
- 2022-0075-0001-0000
- Page Start:
- e89
- Page End:
- e96
- Publication Date:
- 2022-02-28
- Subjects:
- virus transmission -- aerosol-generating procedures -- infection control -- inhalation exposure
Communicable diseases -- Periodicals
616.905 - Journal URLs:
- http://cid.oxfordjournals.org ↗
http://ukcatalogue.oup.com/ ↗
http://www.journals.uchicago.edu/CID/journal ↗
http://www.jstor.org/journals/10584838.html ↗ - DOI:
- 10.1093/cid/ciac161 ↗
- Languages:
- English
- ISSNs:
- 1058-4838
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.293860
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23126.xml