Determining the probability of locating peaks using computerized peak-location methods in gamma-ray spectra as a function of the relative peak-area uncertainty. (January 2020)
- Record Type:
- Journal Article
- Title:
- Determining the probability of locating peaks using computerized peak-location methods in gamma-ray spectra as a function of the relative peak-area uncertainty. (January 2020)
- Main Title:
- Determining the probability of locating peaks using computerized peak-location methods in gamma-ray spectra as a function of the relative peak-area uncertainty
- Authors:
- Ali Santoro, M.C.
Anagnostakis, M.J.
Boshkova, T.
Camacho, A.
Iljadica, M.C. Fornaciari
Collins, S.M.
Perez, R. Diaz
Delgado, J.U.
Đurašavić, M.
Duch, M.A.
Elvira, V.H.
Gomes, R.S.
Gudelis, A.
Gurau, D.
Hurtado Bermudez, S.
Idoeta, R.
Jevremović, A.
Kandić, A.
Korun, M.
Karfopoulos, K.
Laubenstein, M.
Long, S.
Margineanu, R.M.
Mitsios, I.
Mulas, D.
Nikolić, J.K.
Pantelica, A.
Medina, V. Peyres
Pibida, L.
Potiriadis, C.
Silva, R.L.
Siri, S.
Šešlak, B.
Verheyen, L.
Vodenik, B.
Vukanac, I.
Wiedner, H.
Zorko, B.
… (more) - Abstract:
- Abstract: The probabilities of locating peaks with a high relative peak-area uncertainty were determined empirically with nine types of peak-location software used in laboratories engaged in gamma-ray spectrometry measurements. It was found that it is not possible to locate peaks with a probability of 0.95, when they have a relative peak-area uncertainty in excess of 50%. Locating peaks at these relatively high peak-area uncertainties with a probability greater than 0.95 is only possible in the library-driven mode, where the peak positions are supposed a-priori. The deficiencies of the library-driven mode and the possibilities to improve the probabilities of locating peaks are briefly discussed. Highlights: The chance for finding peaks was determined for gamma-ray analyzing software. Peaks with urel < 50% for peak area are located with less than 0.8 probability. In the library-driven mode the chance to find peaks is unity at all uncertainties. At small peaks in the library-driven mode the uncertainties are larger.
- Is Part Of:
- Applied radiation and isotopes. Volume 155(2020:Jan.)
- Journal:
- Applied radiation and isotopes
- Issue:
- Volume 155(2020:Jan.)
- Issue Display:
- Volume 155 (2020)
- Year:
- 2020
- Volume:
- 155
- Issue Sort Value:
- 2020-0155-0000-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-01
- Subjects:
- Gamma-ray spectrometry -- Relative peak-area uncertainty -- Peak location -- Decision threshold
Radiology -- Periodicals
Radiation -- Industrial applications -- Periodicals
Nuclear chemistry -- Periodicals
Internet resource
Periodical
660.298 - Journal URLs:
- http://www.sciencedirect.com/science/journal/09698043 ↗
http://catalog.hathitrust.org/api/volumes/oclc/27456684.html ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.apradiso.2019.108920 ↗
- Languages:
- English
- ISSNs:
- 0969-8043
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1576.565000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23117.xml