A new protocol for the simultaneous flow cytometric analysis of cytotoxicity and immunotoxicity on zebra mussel (Dreissena polymorpha) hemocytes. Issue 98 (March 2020)
- Record Type:
- Journal Article
- Title:
- A new protocol for the simultaneous flow cytometric analysis of cytotoxicity and immunotoxicity on zebra mussel (Dreissena polymorpha) hemocytes. Issue 98 (March 2020)
- Main Title:
- A new protocol for the simultaneous flow cytometric analysis of cytotoxicity and immunotoxicity on zebra mussel (Dreissena polymorpha) hemocytes
- Authors:
- Barjhoux, Iris
Rioult, Damien
Geffard, Alain
Palos Ladeiro, Melissa - Abstract:
- Abstract: Immunotoxicity analysis receives a strong interest in environmental a priori and a posteriori risk assessment procedures considering the direct involvement of the immune system in the health status of organisms, populations and thus ecosystems. The freshwater mussel Dreissena polymorpha is an invasive species widely used in ecotoxicology studies and biomonitoring surveys to evaluate the impacts of contaminants on aquatic fauna. Bivalve hemocytes are the immunocompetent cells circulating in the open circulatory system of the organism. However, there is nowadays no consensus on a protocol to evaluate the immunocompetent state of this particular cell type using flow cytometry. Wild species such as D. polymorpha present several technical barriers complicating their analyze including (i) the quality and the purity of the hemolymph sample, (ii) the controversial characterization of hemocyte subpopulations and their diversity, (iii) the quantity of biological material, and (iv) the high inter-individual variability of hemocyte responses. The present work proposes several technical and analytical improvements to control the above-mentioned issues. The inclusion of sedimentation and cell detachment steps in the pre-analytical phase of the protocol substantially ameliorate the quality of the hemolymph sample as well as the accuracy of the cytometric measurements, by selecting the analyzed cells on their adhesion ability and by increasing the concentration of the analyzedAbstract: Immunotoxicity analysis receives a strong interest in environmental a priori and a posteriori risk assessment procedures considering the direct involvement of the immune system in the health status of organisms, populations and thus ecosystems. The freshwater mussel Dreissena polymorpha is an invasive species widely used in ecotoxicology studies and biomonitoring surveys to evaluate the impacts of contaminants on aquatic fauna. Bivalve hemocytes are the immunocompetent cells circulating in the open circulatory system of the organism. However, there is nowadays no consensus on a protocol to evaluate the immunocompetent state of this particular cell type using flow cytometry. Wild species such as D. polymorpha present several technical barriers complicating their analyze including (i) the quality and the purity of the hemolymph sample, (ii) the controversial characterization of hemocyte subpopulations and their diversity, (iii) the quantity of biological material, and (iv) the high inter-individual variability of hemocyte responses. The present work proposes several technical and analytical improvements to control the above-mentioned issues. The inclusion of sedimentation and cell detachment steps in the pre-analytical phase of the protocol substantially ameliorate the quality of the hemolymph sample as well as the accuracy of the cytometric measurements, by selecting the analyzed cells on their adhesion ability and by increasing the concentration of the analyzed events. The development of an effective triple-labeling procedure including the cellular probe Hoechst® 33342, the membrane impermeant dye propidium iodide and yellow-green fluorescent microspheres allowed the simultaneous analysis of cytotoxicity and phagocytosis activity in hemocytes. It also significantly enhanced the accuracy of hemocyte endpoint measurements by eliminating non-target events from the analysis and allowing relevant gating strategies. Finally, the use of pooled samples of hemolymph noticeably reduced inter-sample variability while providing more plasticity in the experimental design and improving the discriminating potency between treatments. The developed protocol is suitable for ex vivo exposure of hemocyte in a chemical/environmental toxicity assessment as well as for in vivo exposure in the laboratory or in situ biomonitoring surveys with few adaptations. Graphical abstract: Image 1 Highlights: Cell detachment enhances the representativity of the analyzed cell population. The triple labeling procedure improves the accuracy of measured endpoints. Hemocyte adhesion ability is used to select functional cells for further analysis. Hemocyte adhesion is a key property to consider before flow analyses. … (more)
- Is Part Of:
- Fish & shellfish immunology. Issue 98(2020)
- Journal:
- Fish & shellfish immunology
- Issue:
- Issue 98(2020)
- Issue Display:
- Volume 98, Issue 98 (2020)
- Year:
- 2020
- Volume:
- 98
- Issue:
- 98
- Issue Sort Value:
- 2020-0098-0098-0000
- Page Start:
- 224
- Page End:
- 235
- Publication Date:
- 2020-03
- Subjects:
- Immune cells -- Wild species -- Triple labeling -- Bivalve -- Phagocytosis -- Adhesion
%1B+ percentage of events that engulfed one or more bead(s) -- %3B+ percentage of events that engulfed three or more bead(s) -- FSC forward scatter -- H (+/-) Hoechst® 33342 (positive/negative) -- L15-15%⊕ L15 medium diluted at 15% and supplemented with glutamine and streptomycin -- PI (+/-) propidium iodide (positive/negative) -- R1 hemocyte region/gate -- SSC side scatter -- YG beads yellow-green fluorescent polystyrene beads
Fishes -- Immunology -- Periodicals
Shellfish -- Immunology -- Periodicals
Poissons -- Immunologie -- Périodiques
Crustacés -- Immunologie -- Périodiques
571.9617 - Journal URLs:
- http://www.sciencedirect.com/science/journal/10504648 ↗
http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=1050-4648;screen=info;ECOIP ↗
http://www.sciencedirect.com/science/journal/latest/10504648 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.fsi.2019.12.092 ↗
- Languages:
- English
- ISSNs:
- 1050-4648
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3934.880000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23133.xml