A computational parametric study on edge loading in ceramic-on-ceramic total hip joint replacements. (July 2018)
- Record Type:
- Journal Article
- Title:
- A computational parametric study on edge loading in ceramic-on-ceramic total hip joint replacements. (July 2018)
- Main Title:
- A computational parametric study on edge loading in ceramic-on-ceramic total hip joint replacements
- Authors:
- Liu, Feng
Feng, Li
Wang, Junyuan - Abstract:
- Abstract: Edge loading in ceramic-on-ceramic total hip joint replacement is an adverse condition that occurs as the result of a direct contact between the head and the cup rim. It has been associated with translational mismatch in the centres of rotation of the cup and head, and found to cause severe wear and early failure of the implants. Edge loading has been considered in particular in relation to dynamic separation of the cup and head centres during a gait cycle. Research has been carried out both experimentally and computationally to understand the mechanism including the influence of bearing component positioning on the occurrence and severity of edge loading. However, it is experimentally difficult to measure both the load magnitude and duration of edge loading as it occurs as a short impact within the tight space of hip joints. Computationally, a dynamic contact model, for example, developed using the MSC ADAMS software for a multi-body dynamics simulation can be particularly useful for calculating the loads and characterising the edge loading. The aim of the present study was to further develop the computational model, and improve the predictions of contact force and the understanding of mechanism in order to provide guidance on design and surgical factors to avoid or to reduce edge loading and wear. The results have shown that edge loading can be avoided for a low range of translational mismatch in the centres of rotation of the cup and head during gait at theAbstract: Edge loading in ceramic-on-ceramic total hip joint replacement is an adverse condition that occurs as the result of a direct contact between the head and the cup rim. It has been associated with translational mismatch in the centres of rotation of the cup and head, and found to cause severe wear and early failure of the implants. Edge loading has been considered in particular in relation to dynamic separation of the cup and head centres during a gait cycle. Research has been carried out both experimentally and computationally to understand the mechanism including the influence of bearing component positioning on the occurrence and severity of edge loading. However, it is experimentally difficult to measure both the load magnitude and duration of edge loading as it occurs as a short impact within the tight space of hip joints. Computationally, a dynamic contact model, for example, developed using the MSC ADAMS software for a multi-body dynamics simulation can be particularly useful for calculating the loads and characterising the edge loading. The aim of the present study was to further develop the computational model, and improve the predictions of contact force and the understanding of mechanism in order to provide guidance on design and surgical factors to avoid or to reduce edge loading and wear. The results have shown that edge loading can be avoided for a low range of translational mismatch in the centres of rotation of the cup and head during gait at the level of approximately 1.0 mm for a cup at 45° inclination, keeping a correct cup inclination at 45° is important to reduce the edge loading severity, and edge loading can be avoided for a certain range of translational mismatch of the cup and head centres with an increased swing phase load. Highlights: A model using the Adams software to simulate dynamic separation and edge loading in ceramic total hip joint replacements. The stiffness coefficient of contact model was determined. Friction associated with the experimental simulator mechanism was studied. The effect of translational mismatch in the centres of rotation of the cup and head (0–4 mm) on edge loading was studied. Edge loading may be avoided for the cup at a correct inclination with a low level of translational mismatch. … (more)
- Is Part Of:
- Journal of the mechanical behavior of biomedical materials. Volume 83(2018)
- Journal:
- Journal of the mechanical behavior of biomedical materials
- Issue:
- Volume 83(2018)
- Issue Display:
- Volume 83, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 83
- Issue:
- 2018
- Issue Sort Value:
- 2018-0083-2018-0000
- Page Start:
- 135
- Page End:
- 142
- Publication Date:
- 2018-07
- Subjects:
- Edge loading -- Multi-body dynamics -- Ceramic-on-ceramic bearings -- Hip joint replacement -- Wear -- Hip joint alignment
Biomedical materials -- Periodicals
Biomedical materials -- Mechanical properties -- Periodicals
Biomedical materials
Biomedical materials -- Mechanical properties
Periodicals
Electronic journals
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/17516161 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jmbbm.2018.04.018 ↗
- Languages:
- English
- ISSNs:
- 1751-6161
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5015.809000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23132.xml