Determination of phthalic acid esters in water samples by hollow fiber liquid-phase microextraction prior to gas chromatography tandem mass spectrometry. (June 2018)
- Record Type:
- Journal Article
- Title:
- Determination of phthalic acid esters in water samples by hollow fiber liquid-phase microextraction prior to gas chromatography tandem mass spectrometry. (June 2018)
- Main Title:
- Determination of phthalic acid esters in water samples by hollow fiber liquid-phase microextraction prior to gas chromatography tandem mass spectrometry
- Authors:
- González-Sálamo, Javier
González-Curbelo, Miguel Ángel
Socas-Rodríguez, Bárbara
Hernández-Borges, Javier
Rodríguez-Delgado, Miguel Ángel - Abstract:
- Abstract: A new hollow fiber liquid-phase microextraction (HF-LPME) method has been developed for the extraction of a group of phthalic acid esters (PAEs) of interest from different water samples prior to gas chromatography tandem mass spectrometry analysis. HF-LPME was carried out using 1-octanol as extraction solvent followed by a back extraction step with cyclohexane. The different parameters that affect HF-LPME such as sample pH, ionic strength, extraction time, stirring rate, extraction temperature and back extraction conditions were investigated. The optimized conditions involved the extraction of 10 mL of sample without pH adjustment or addition of salt during 75 min under a stirring of 850 rpm at 60 °C and subsequent desorption with 200 μL of cyclohexane for 10 min in an ultrasonic bath. The method was validated in terms of calibration and recovery studies using dibutyl phthalate-d4 as internal standard. The developed procedure gave satisfactory recovery (74–120%) and relative standard deviation values (<20%) for the studied PAEs in mineral, tap, pond and waste water samples. Highlights: A new HF-LPME-GC-MS/MS method was developed for the analysis of PAEs. Mineral, tap, pond and waste water samples were analyzed. Main parameters affecting the extraction efficiency were optimized. Recoveries ranged between 74 and 120% with RSD values below 20%. The developed method is simple, cheap and reliable.
- Is Part Of:
- Chemosphere. Volume 201(2018)
- Journal:
- Chemosphere
- Issue:
- Volume 201(2018)
- Issue Display:
- Volume 201, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 201
- Issue:
- 2018
- Issue Sort Value:
- 2018-0201-2018-0000
- Page Start:
- 254
- Page End:
- 261
- Publication Date:
- 2018-06
- Subjects:
- Phthalic acid esters -- Water samples -- Hollow fiber liquid-phase microextraction -- Gas chromatography tandem mass spectrometry
Pollution -- Periodicals
Pollution -- Physiological effect -- Periodicals
Environmental sciences -- Periodicals
Atmospheric chemistry -- Periodicals
551.511 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00456535/ ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.chemosphere.2018.02.180 ↗
- Languages:
- English
- ISSNs:
- 0045-6535
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3172.280000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 23115.xml