A comparison between DART-MS and DSA-MS in the forensic analysis of writing inks. (August 2018)
- Record Type:
- Journal Article
- Title:
- A comparison between DART-MS and DSA-MS in the forensic analysis of writing inks. (August 2018)
- Main Title:
- A comparison between DART-MS and DSA-MS in the forensic analysis of writing inks
- Authors:
- Drury, Nicholas
Ramotowski, Robert
Moini, Mehdi - Abstract:
- Graphical abstract: Highlights: Comparison between DART-MS and DSA-MS for the analysis of components in writing inks. Advantages and disadvantages of DART-MS vs. DSA-MS for the analysis of writing inks. Because of its open-source configuration DART-MS provided higher sensitivity and repeatability. Because of its closed-source configuration DSA-MS provided lower chemical background noise. Abstract: Ambient ionization mass spectrometry is gaining momentum in forensic science laboratories because of its high speed of analysis, minimal sample preparation, and information-rich results. One such application of ambient ionization methodology includes the analysis of writing inks from questioned documents where colorants of interest may not be soluble in common solvents, rendering thin layer chromatography (TLC) and separation–mass spectrometry methods such as LC/MS (-MS) impractical. Ambient ionization mass spectrometry uses a variety of ionization techniques such as penning ionization in Direct Analysis in Real Time (DART), and atmospheric pressure chemical ionization in Direct Sample Analysis (DSA), and electrospray ionization in Desorption Electrospray Ionization (DESI). In this manuscript, two of the commonly used ambient ionization techniques are compared: Perkin Elmer DSA-MS and IonSense DART in conjunction with a JEOL AccuTOF MS. Both technologies were equally successful in analyzing writing inks and produced similar spectra. DSA-MS produced less background signal likelyGraphical abstract: Highlights: Comparison between DART-MS and DSA-MS for the analysis of components in writing inks. Advantages and disadvantages of DART-MS vs. DSA-MS for the analysis of writing inks. Because of its open-source configuration DART-MS provided higher sensitivity and repeatability. Because of its closed-source configuration DSA-MS provided lower chemical background noise. Abstract: Ambient ionization mass spectrometry is gaining momentum in forensic science laboratories because of its high speed of analysis, minimal sample preparation, and information-rich results. One such application of ambient ionization methodology includes the analysis of writing inks from questioned documents where colorants of interest may not be soluble in common solvents, rendering thin layer chromatography (TLC) and separation–mass spectrometry methods such as LC/MS (-MS) impractical. Ambient ionization mass spectrometry uses a variety of ionization techniques such as penning ionization in Direct Analysis in Real Time (DART), and atmospheric pressure chemical ionization in Direct Sample Analysis (DSA), and electrospray ionization in Desorption Electrospray Ionization (DESI). In this manuscript, two of the commonly used ambient ionization techniques are compared: Perkin Elmer DSA-MS and IonSense DART in conjunction with a JEOL AccuTOF MS. Both technologies were equally successful in analyzing writing inks and produced similar spectra. DSA-MS produced less background signal likely because of its closed source configuration; however, the open source configuration of DART-MS provided more flexibility for sample positioning for optimum sensitivity and thereby allowing smaller piece of paper containing writing ink to be analyzed. Under these conditions, the minimum sample required for DART-MS was 1 mm strokes of ink on paper, whereas DSA-MS required a minimum of 3 mm. Moreover, both techniques showed comparable repeatability. Evaluation of the analytical figures of merit, including sensitivity, linear dynamic range, and repeatability, for DSA-MS and DART-MS analysis is provided. To the forensic context of the technique, DART-MS was applied to the analysis of United States Secret Service ink samples directly on a sampling mesh, and the results were compared with DSA-MS of the same inks on paper. Unlike analysis using separation mass spectrometry, which requires sample preparation, both DART-MS and DSA-MS successfully analyzed writing inks with minimal sample preparation. … (more)
- Is Part Of:
- Forensic science international. Volume 289(2018)
- Journal:
- Forensic science international
- Issue:
- Volume 289(2018)
- Issue Display:
- Volume 289, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 289
- Issue:
- 2018
- Issue Sort Value:
- 2018-0289-2018-0000
- Page Start:
- 27
- Page End:
- 32
- Publication Date:
- 2018-08
- Subjects:
- DART/TOF-MS -- DSA/TOF-MS -- Forensic science -- Ink analysis
Medical jurisprudence -- Periodicals
Chemistry, Forensic -- Periodicals
Forensic Medicine -- Periodicals
Médecine légale -- Périodiques
Chimie légale -- Périodiques
Gerechtelijke geneeskunde
Gerechtelijke chemie
Gerechtelijke psychiatrie
Chemistry, Forensic
Medical jurisprudence
Electronic journals
Periodicals
Electronic journals
614.1 - Journal URLs:
- http://www.clinicalkey.com.au/dura/browse/journalIssue/03790738 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/03790738 ↗
http://www.sciencedirect.com/science/journal/03790738 ↗
http://infotrac.galegroup.com/itw/infomark/1/1/1/purl=rc18_EAIM_0__jn+%22Forensic+Science+International%22?sw_aep=stand ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.forsciint.2018.05.009 ↗
- Languages:
- English
- ISSNs:
- 0379-0738
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3987.764000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23120.xml