Advantages of using larger-diameter pinhole collimator for prompt X-ray imaging during irradiation with carbon ions. (1st September 2022)
- Record Type:
- Journal Article
- Title:
- Advantages of using larger-diameter pinhole collimator for prompt X-ray imaging during irradiation with carbon ions. (1st September 2022)
- Main Title:
- Advantages of using larger-diameter pinhole collimator for prompt X-ray imaging during irradiation with carbon ions
- Authors:
- Yamamoto, Seiichi
Yabe, Takuya
Akagi, Takashi
Yamaguchi, Mitsutaka
Kawachi, Naoki
Kamada, Kei
Yoshikawa, Akira
Kataoka, Jun - Abstract:
- Abstract: Prompt secondary electron bremsstrahlung X-ray (prompt X-ray) imaging using a low-energy X-ray camera is a promising method for observing a beam shape from outside the subject. However, the images measured within short times suffer from statistical noise. Consequently, we performed prompt X-ray imaging with higher sensitivity using a larger-diameter pinhole collimator and compared the results with those of a conventional collimator. Prompt X-ray imaging was conducted during irradiation with pencil beams of 241.5-MeV/n carbon ions to a water phantom. A newly developed X-ray camera with a 4-mm diameter as well as conventional 1.5-mm-diameter pinhole collimators was used for the imaging in list mode, and we compared the prompt X-ray images, energy spectra, and time count rate curves between 1.5-mm-diameter and 4-mm-diameter pinhole collimators. The prompt X-ray images taken with the 4-mm-diameter pinhole collimators had ∼7 times higher sensitivity with 70 % lower offset fractions originating from the prompt gamma photons. Furthermore, the ranges were more precisely estimated with the 4-mm collimator than with the 1.5-mm collimator. The energy spectra showed less contamination by tungsten-characteristic X-rays for the 4-mm pinhole collimator. Even for images measured with 0.1-s intervals, the beam shapes and time count rate curves could be obtained with less statistical noise using the 4-mm-diameter pinhole collimators. The use of the 4-mm-diameter pinhole collimatorAbstract: Prompt secondary electron bremsstrahlung X-ray (prompt X-ray) imaging using a low-energy X-ray camera is a promising method for observing a beam shape from outside the subject. However, the images measured within short times suffer from statistical noise. Consequently, we performed prompt X-ray imaging with higher sensitivity using a larger-diameter pinhole collimator and compared the results with those of a conventional collimator. Prompt X-ray imaging was conducted during irradiation with pencil beams of 241.5-MeV/n carbon ions to a water phantom. A newly developed X-ray camera with a 4-mm diameter as well as conventional 1.5-mm-diameter pinhole collimators was used for the imaging in list mode, and we compared the prompt X-ray images, energy spectra, and time count rate curves between 1.5-mm-diameter and 4-mm-diameter pinhole collimators. The prompt X-ray images taken with the 4-mm-diameter pinhole collimators had ∼7 times higher sensitivity with 70 % lower offset fractions originating from the prompt gamma photons. Furthermore, the ranges were more precisely estimated with the 4-mm collimator than with the 1.5-mm collimator. The energy spectra showed less contamination by tungsten-characteristic X-rays for the 4-mm pinhole collimator. Even for images measured with 0.1-s intervals, the beam shapes and time count rate curves could be obtained with less statistical noise using the 4-mm-diameter pinhole collimators. The use of the 4-mm-diameter pinhole collimator attached to the X-ray camera had advantages for prompt X-ray imaging with high sensitivity and low background, enabling us to image the beams even with short-time measurements. … (more)
- Is Part Of:
- Journal of instrumentation. Volume 17:Number 9(2022)
- Journal:
- Journal of instrumentation
- Issue:
- Volume 17:Number 9(2022)
- Issue Display:
- Volume 17, Issue 9 (2022)
- Year:
- 2022
- Volume:
- 17
- Issue:
- 9
- Issue Sort Value:
- 2022-0017-0009-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-09-01
- Subjects:
- Gamma camera, SPECT, PET PET/CT, coronary CT angiography (CTA) -- Gamma detectors (scintillators, CZT, HPGe, HgI etc) -- Instrumentation for heavy-ion therapy -- Instrumentation for particle-beam therapy
Scientific apparatus and instruments -- Periodicals
502.84 - Journal URLs:
- http://iopscience.iop.org/1748-0221 ↗
http://ioppublishing.org/ ↗ - DOI:
- 10.1088/1748-0221/17/09/P09006 ↗
- Languages:
- English
- ISSNs:
- 1748-0221
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23100.xml