Enhancement of Electromigration Reliability of Electroless-Plated Nanoscaled Copper Interconnects by Complete Encapsulation of a 1 nm-Thin Self-Assembled Monolayer. Issue 8 (1st August 2022)
- Record Type:
- Journal Article
- Title:
- Enhancement of Electromigration Reliability of Electroless-Plated Nanoscaled Copper Interconnects by Complete Encapsulation of a 1 nm-Thin Self-Assembled Monolayer. Issue 8 (1st August 2022)
- Main Title:
- Enhancement of Electromigration Reliability of Electroless-Plated Nanoscaled Copper Interconnects by Complete Encapsulation of a 1 nm-Thin Self-Assembled Monolayer
- Authors:
- Chen, Giin-Shan
Lee, Ching-En
Cheng, Yi-Lung
Fang, Jau-Shiung
Hsiao, Chien-Nan
Chen, Wei-Chun
Chang, Yiu-Hsiang
Pan, Yen-Chang
Lee, Wei
Su, Ting-Hsun - Abstract:
- Abstract : The downsizing of integrated circuits for the upcoming technology nodes has brought attention to sub-2 nm thin organic/inorganic materials as an alternative to metallic barrier/capping layers for nanoscaled Cu interconnects. While self-assembled monolayers (SAMs) serving as the barrier materials for copper metalized films are well studied, electromigration (EM) of Cu interconnects encapsulated by SAMs is an untouched research topic. In this study, we report an all-wet encapsulating process involving SAM seeding/encapsulating and electroless narrow-gap filling to fabricate nanoscaled copper interconnects that are completely encapsulated by a 1 nm-thin amino-based SAM, subsequently annealed to some extents prior to EM testing. Both annealing and SAM encapsulation retard EM of the Cu interconnects tested at current densities on orders of 10 8 –10 9 A cm −2 . Particularly, SAM encapsulation quintuples the lifetime of, for example, as-fabricated Cu interconnects from 470 to 2, 890 s. Electromigration failure mechanisms are elucidated from analyses of activation energies and current-density scale factors obtained from the accelerated EM testing. The importance of SAM qualities (e.g., ordering and layered structure) as a prerequisite for the reliability enhancement cannot be overestimated, and the results of the SAM quality evaluation are presented. The mechanism of reliability enhancement is also thoroughly discussed.
- Is Part Of:
- Journal of the Electrochemical Society. Volume 169:Issue 8(2022)
- Journal:
- Journal of the Electrochemical Society
- Issue:
- Volume 169:Issue 8(2022)
- Issue Display:
- Volume 169, Issue 8 (2022)
- Year:
- 2022
- Volume:
- 169
- Issue:
- 8
- Issue Sort Value:
- 2022-0169-0008-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-08-01
- Subjects:
- Cu interconnect -- electroless plating -- self-assembled monolayer -- electromigration -- black's equation
Electrochemistry -- Periodicals
541.3705 - Journal URLs:
- https://iopscience.iop.org/journal/1945-7111?gclid=EAIaIQobChMI4Y-UmqGC7wIVFeDtCh0VQAo7EAAYASAAEgLW8_D_BwE ↗
- DOI:
- 10.1149/1945-7111/ac89b8 ↗
- Languages:
- English
- ISSNs:
- 0013-4651
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library HMNTS - ELD Digital store
- Ingest File:
- 23103.xml