Effects of shoulder distraction on canine shoulder arthroscopy. Issue 2 (5th January 2021)
- Record Type:
- Journal Article
- Title:
- Effects of shoulder distraction on canine shoulder arthroscopy. Issue 2 (5th January 2021)
- Main Title:
- Effects of shoulder distraction on canine shoulder arthroscopy
- Authors:
- Aoki, Koji
Sek, Jun‐Yan
de Paula Freitas, Fernando
Bates, Miriam
Beaufrere, Hugues - Abstract:
- Abstract: Objective: To evaluate the use of the Leipzig distractor during canine shoulder arthroscopy. Study design: Experimental, ex vivo. Sample population: Paired shoulder joints from 15 large breed canine cadavers. Methods: Standard lateral shoulder arthroscopy was performed with or without the use of the Leipzig distractor (n = 15 each). Joint space width, procedure time, and visibility and palpability of the intra‐articular structures were assessed during the arthroscopy. After the arthroscopic evaluation, each shoulder joint was disarticulated to assess the area and number of iatrogenic articular cartilage injury (IACI) lesions. Sites around the distraction device were assessed for the presence of iatrogenic injury. Results: With shoulder distraction, median joint space width was 4 mm larger ( P = .01), IACI area was 9.5 mm 2 lower ( P = .003), and there were two fewer total number of IACI lesions ( P = .004) compared with nondistracted shoulders. The mean total surgery time was 93 seconds shorter ( P = .01) in distracted shoulders. Although distraction was associated with increased visibility of the supraglenoid tubercle ( P = .015), no significant differences were found for other intra‐articular structures for their visibility and palpability. Unexpected lesions at the sites around the distraction device were not encountered. Conclusion: Use of the distraction device decreased the area and incidence of IACI lesions and shortened the arthroscopy time. However, noAbstract: Objective: To evaluate the use of the Leipzig distractor during canine shoulder arthroscopy. Study design: Experimental, ex vivo. Sample population: Paired shoulder joints from 15 large breed canine cadavers. Methods: Standard lateral shoulder arthroscopy was performed with or without the use of the Leipzig distractor (n = 15 each). Joint space width, procedure time, and visibility and palpability of the intra‐articular structures were assessed during the arthroscopy. After the arthroscopic evaluation, each shoulder joint was disarticulated to assess the area and number of iatrogenic articular cartilage injury (IACI) lesions. Sites around the distraction device were assessed for the presence of iatrogenic injury. Results: With shoulder distraction, median joint space width was 4 mm larger ( P = .01), IACI area was 9.5 mm 2 lower ( P = .003), and there were two fewer total number of IACI lesions ( P = .004) compared with nondistracted shoulders. The mean total surgery time was 93 seconds shorter ( P = .01) in distracted shoulders. Although distraction was associated with increased visibility of the supraglenoid tubercle ( P = .015), no significant differences were found for other intra‐articular structures for their visibility and palpability. Unexpected lesions at the sites around the distraction device were not encountered. Conclusion: Use of the distraction device decreased the area and incidence of IACI lesions and shortened the arthroscopy time. However, no improvement was found in the visibility or palpability of the intra‐articular structures. Clinical significance: Although additional clinical studies are required to evaluate the effect of the distraction device on pathologic articular conditions and intraoperative manipulation, the use of a shoulder distraction device might improve the outcomes of shoulder arthroscopy by decreasing IACI and arthroscopy time. … (more)
- Is Part Of:
- Veterinary surgery. Volume 50:Issue 2(2021)
- Journal:
- Veterinary surgery
- Issue:
- Volume 50:Issue 2(2021)
- Issue Display:
- Volume 50, Issue 2 (2021)
- Year:
- 2021
- Volume:
- 50
- Issue:
- 2
- Issue Sort Value:
- 2021-0050-0002-0000
- Page Start:
- 375
- Page End:
- 382
- Publication Date:
- 2021-01-05
- Subjects:
- Veterinary surgery -- Periodicals
Veterinary Medicine -- Periodicals
Surgery -- Periodicals
Societies, Medical -- Periodicals
636.0897 - Journal URLs:
- http://www.blackwell-synergy.com/loi/vsu ↗
http://www.blackwell-synergy.com/servlet/useragent?func=showIssues&code=vsu ↗
http://www.harcourthealth.com/vetsurg ↗
http://onlinelibrary.wiley.com/ ↗
http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=0161-3499;screen=info;ECOIP ↗ - DOI:
- 10.1111/vsu.13562 ↗
- Languages:
- English
- ISSNs:
- 0161-3499
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 9231.037000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23112.xml