Evaluation of the efficacy and safety of a new flex‐rigid pleuroscope. (28th September 2020)
- Record Type:
- Journal Article
- Title:
- Evaluation of the efficacy and safety of a new flex‐rigid pleuroscope. (28th September 2020)
- Main Title:
- Evaluation of the efficacy and safety of a new flex‐rigid pleuroscope
- Authors:
- Ishii, Satoru
Watanabe, Hiromu
Suzuki, Manabu
Hashimoto, Masao
Iikura, Motoyasu
Izumi, Shinyu
Hojo, Masayuki
Sugiyama, Haruhito - Abstract:
- Abstract: Objective: New flex‐rigid pleuroscope enables observations with a maximum angle of curvature of 180 °, allowing visualization of the area near the insertion site of the pleuroscope. And, it improved the image quality and channel inner diameter. The aim of this study was to evaluate the clinical effectiveness and safety of a new flex‐rigid pleuroscope. Methods: A retrospective analysis of patients who were examined with a new flex‐rigid pleuroscope under local anesthesia at our institution was conducted. Pleuroscopy was performed in 33 patients with undiagnosed exudative pleural effusions from December 2016 to March 2019. Results: A total of 33 patients (10 women, 23 men); their median age 74 years (range 24‐90) were investigated. Pleuroscopy showed that 18 had malignant pleural disease (54%), and 15 had benign pleural diseases (46%). The top three most frequent causes of pleural disease were pleural metastases of lung carcinoma (30.3%), pyothorax (15.1%), and malignant pleural mesothelioma (12.1%). In 32 cases (97%), observation at the introducer insertion site was possible. It was not possible in one case due to hard adhesions. The diagnostic rate was 100%, and the complication rate was 6.1%. There were no major complications, and minor complications included mild pain (one case) and minor bleeding (one case) that was stanched spontaneously. Conclusions: The new flex‐rigid pleuroscope is effective and safe for diagnosing pleural effusions. The improved bendingAbstract: Objective: New flex‐rigid pleuroscope enables observations with a maximum angle of curvature of 180 °, allowing visualization of the area near the insertion site of the pleuroscope. And, it improved the image quality and channel inner diameter. The aim of this study was to evaluate the clinical effectiveness and safety of a new flex‐rigid pleuroscope. Methods: A retrospective analysis of patients who were examined with a new flex‐rigid pleuroscope under local anesthesia at our institution was conducted. Pleuroscopy was performed in 33 patients with undiagnosed exudative pleural effusions from December 2016 to March 2019. Results: A total of 33 patients (10 women, 23 men); their median age 74 years (range 24‐90) were investigated. Pleuroscopy showed that 18 had malignant pleural disease (54%), and 15 had benign pleural diseases (46%). The top three most frequent causes of pleural disease were pleural metastases of lung carcinoma (30.3%), pyothorax (15.1%), and malignant pleural mesothelioma (12.1%). In 32 cases (97%), observation at the introducer insertion site was possible. It was not possible in one case due to hard adhesions. The diagnostic rate was 100%, and the complication rate was 6.1%. There were no major complications, and minor complications included mild pain (one case) and minor bleeding (one case) that was stanched spontaneously. Conclusions: The new flex‐rigid pleuroscope is effective and safe for diagnosing pleural effusions. The improved bending angle is likely to minimize the blind area. The new pleuroscopy fiberscope may improve the diagnostic rate. … (more)
- Is Part Of:
- Clinical respiratory journal. Volume 15:Number 1(2021)
- Journal:
- Clinical respiratory journal
- Issue:
- Volume 15:Number 1(2021)
- Issue Display:
- Volume 15, Issue 1 (2021)
- Year:
- 2021
- Volume:
- 15
- Issue:
- 1
- Issue Sort Value:
- 2021-0015-0001-0000
- Page Start:
- 91
- Page End:
- 96
- Publication Date:
- 2020-09-28
- Subjects:
- flex‐rigid pleuroscope -- LTF‐Y0032 -- pleural biopsy -- pleural effusion
Respiratory organs -- Diseases -- Periodicals
Respiratory organs -- Periodicals
616.24 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1752-699X ↗
http://www.blackwell-synergy.com/loi/CRJ ↗
http://ezproxy.aut.ac.nz/login?url=http://YU7RZ9HN8Y.search.serialssolutions.com/?V=1.0&L=YU7RZ9HN8Y&S=JCs&C=THCRJ&T=marc ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/crj.13274 ↗
- Languages:
- English
- ISSNs:
- 1752-6981
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.374350
British Library DSC - BLDSS-3PM
British Library STI - Digital store
British Library STI - ELD Digital store - Ingest File:
- 23113.xml