Clinical impact of amotosalen‐ultraviolet A pathogen‐inactivated platelets stored for up to 7 days. Issue 11 (1st October 2019)
- Record Type:
- Journal Article
- Title:
- Clinical impact of amotosalen‐ultraviolet A pathogen‐inactivated platelets stored for up to 7 days. Issue 11 (1st October 2019)
- Main Title:
- Clinical impact of amotosalen‐ultraviolet A pathogen‐inactivated platelets stored for up to 7 days
- Authors:
- Infanti, Laura
Holbro, Andreas
Passweg, Jakob
Bolliger, Daniel
Tsakiris, Dimitrios A.
Merki, Ramona
Plattner, Alexandra
Tappe, David
Irsch, Johannes
Lin, Jin‐Sying
Corash, Laurence
Benjamin, Richard J.
Buser, Andreas - Abstract:
- Abstract : BACKGROUND: Universal pathogen inactivation of platelet concentrates (PCs) using amotosalen/ultraviolet A with 7‐day storage was implemented in Switzerland in 2011. Routine‐use data were analyzed at the University Hospital Basel, Switzerland. STUDY DESIGN: A retrospective two‐cohort study of patient and PC characteristics, component usage, patient outcomes, count increments (CIs), and adverse events were analyzed for two consecutive 5‐year periods with either 0‐ to 5‐day‐old conventional PC (C‐PC) (n = 14, 181) or 0‐ to 7‐day‐old pathogen‐inactivated PC (PI‐PC) (n = 22, 579). RESULTS: In both periods, PCs were issued for transfusion on a "first in, first out" basis. With 7‐day PI‐PC, wastage was reduced from 8.7% to 1.5%; 16.6% of transfused PI‐PCs were more than 5 days old. Transfusion of PI‐PC more than 5 days old compared with 5 days old or less did not increase platelet and RBC use on the same or next day as an indirect measure of hemostasis and did not increase transfusion reactions. Mean corrected count increments (CCIs) for PI‐PC stored for 5 days or less were 22.6% lower than for C‐PC (p < 0.001), and declined with increasing storage duration for both, although the correlation was weak (r 2 = 0.005‐0.014). Mean number of PCs used per patient and duration of PC support were not different for hematology/oncology, allogeneic and autologous hematopoietic stem cell transplant (HSCT), and general medical/surgical patients, who used the majority (~92.0%) ofAbstract : BACKGROUND: Universal pathogen inactivation of platelet concentrates (PCs) using amotosalen/ultraviolet A with 7‐day storage was implemented in Switzerland in 2011. Routine‐use data were analyzed at the University Hospital Basel, Switzerland. STUDY DESIGN: A retrospective two‐cohort study of patient and PC characteristics, component usage, patient outcomes, count increments (CIs), and adverse events were analyzed for two consecutive 5‐year periods with either 0‐ to 5‐day‐old conventional PC (C‐PC) (n = 14, 181) or 0‐ to 7‐day‐old pathogen‐inactivated PC (PI‐PC) (n = 22, 579). RESULTS: In both periods, PCs were issued for transfusion on a "first in, first out" basis. With 7‐day PI‐PC, wastage was reduced from 8.7% to 1.5%; 16.6% of transfused PI‐PCs were more than 5 days old. Transfusion of PI‐PC more than 5 days old compared with 5 days old or less did not increase platelet and RBC use on the same or next day as an indirect measure of hemostasis and did not increase transfusion reactions. Mean corrected count increments (CCIs) for PI‐PC stored for 5 days or less were 22.6% lower than for C‐PC (p < 0.001), and declined with increasing storage duration for both, although the correlation was weak (r 2 = 0.005‐0.014). Mean number of PCs used per patient and duration of PC support were not different for hematology/oncology, allogeneic and autologous hematopoietic stem cell transplant (HSCT), and general medical/surgical patients, who used the majority (~92.0%) of PI‐PCs. Five‐year treatment‐related mortality in allogeneic HSCT was unchanged in the PI‐PC period. CONCLUSIONS: PI‐PCs with 7‐day storage reduced wastage and did not increase PC or red blood cell utilization or adverse reactions compared with fresh PI‐PC or a historical control group, demonstrating preserved efficacy and safety. … (more)
- Is Part Of:
- Transfusion. Volume 59:Issue 11(2019)
- Journal:
- Transfusion
- Issue:
- Volume 59:Issue 11(2019)
- Issue Display:
- Volume 59, Issue 11 (2019)
- Year:
- 2019
- Volume:
- 59
- Issue:
- 11
- Issue Sort Value:
- 2019-0059-0011-0000
- Page Start:
- 3350
- Page End:
- 3361
- Publication Date:
- 2019-10-01
- Subjects:
- Hematology -- Periodicals
Blood -- Transfusion -- Periodicals
Blood Group Antigens -- Periodicals
Blood Preservation -- Periodicals
Blood Transfusion -- Periodicals
615 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1537-2995 ↗
http://www.blackwell-synergy.com/member/institutions/issuelist.asp?journal=trf ↗
http://www.transfusion.org ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/trf.15511 ↗
- Languages:
- English
- ISSNs:
- 0041-1132
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 9020.704000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 23088.xml