Are small-sized mechanical valves adequate for patients with small aortic roots?. (November 2022)
- Record Type:
- Journal Article
- Title:
- Are small-sized mechanical valves adequate for patients with small aortic roots?. (November 2022)
- Main Title:
- Are small-sized mechanical valves adequate for patients with small aortic roots?
- Authors:
- Pandey, Pratik
Saha, Apu
Jha, Neeraj Kumar
Rao, Yashaskar Manjunatha
Das, Debasis
Das, Mrinalendu
Chatterjee, Debika
Narayan, Pradeep - Abstract:
- Aim: Concerns have been raised over patient outcomes following implantation of small aortic valves (size: 19 and 17 mm). However, in patients with a smaller body surface area, these valves may be adequate. The aim of th study was to assess the hemodynamic and functional performance of these valves and their impact on clinical outcomes in patients with a small aortic root. Material and methods: This was a prospective observational study that included all consecutive patients undergoing aortic valve replacement (AVR) with a small-sized aortic valve over a 3-year period. Patients were followed up at 1 week, 6 weeks, and 1 year. Functional and clinical evaluation along with echocardiography was carried out for hemodynamic assessment. In-hospital mortality and hemodynamic outcomes at 1-year follow-up were recorded. Results: Isolated AVR with a size 17 mm valve was carried out in 15 (25%) and with a 19 mm valve in 45 (75%) patients. The mean annular size was 19.12 ± 2.03 mm. The mean indexed effective orifice area was 1.08 ± 0.16 cm 2 /m 2 . Satisfactory decrease in peak and mean trans-prosthetic gradient were evident (peak gradient preoperatively was 92.15 ± 26.2 mmHg, and 25.68 ± 12.28 mmHg at 1 year, mean gradient was 55.31 ± 17.41 mmHg preoperatively and 13.71 ± 7.39 mmHg at 1 year). The functional status of patients also showed significant improvement post AVR. Left ventricular ejection fraction pre-operatively was 59.67% ± 10.38% and 59.57% ± 7.98% at 1-week, 59.15% ± 8.17%Aim: Concerns have been raised over patient outcomes following implantation of small aortic valves (size: 19 and 17 mm). However, in patients with a smaller body surface area, these valves may be adequate. The aim of th study was to assess the hemodynamic and functional performance of these valves and their impact on clinical outcomes in patients with a small aortic root. Material and methods: This was a prospective observational study that included all consecutive patients undergoing aortic valve replacement (AVR) with a small-sized aortic valve over a 3-year period. Patients were followed up at 1 week, 6 weeks, and 1 year. Functional and clinical evaluation along with echocardiography was carried out for hemodynamic assessment. In-hospital mortality and hemodynamic outcomes at 1-year follow-up were recorded. Results: Isolated AVR with a size 17 mm valve was carried out in 15 (25%) and with a 19 mm valve in 45 (75%) patients. The mean annular size was 19.12 ± 2.03 mm. The mean indexed effective orifice area was 1.08 ± 0.16 cm 2 /m 2 . Satisfactory decrease in peak and mean trans-prosthetic gradient were evident (peak gradient preoperatively was 92.15 ± 26.2 mmHg, and 25.68 ± 12.28 mmHg at 1 year, mean gradient was 55.31 ± 17.41 mmHg preoperatively and 13.71 ± 7.39 mmHg at 1 year). The functional status of patients also showed significant improvement post AVR. Left ventricular ejection fraction pre-operatively was 59.67% ± 10.38% and 59.57% ± 7.98% at 1-week, 59.15% ± 8.17% at 6 weeks, and 59.59% ± 7.48% at 1 year. Conclusion: When confronted with a small aortic root, AVR with a small-sized prosthesis provides a satisfactory hemodynamic and functional outcome. In patients with small body surface area, implantation of a small-sized valve is a viable option. … (more)
- Is Part Of:
- Asian cardiovascular & thoracic annals. Volume 30:Number 9(2022)
- Journal:
- Asian cardiovascular & thoracic annals
- Issue:
- Volume 30:Number 9(2022)
- Issue Display:
- Volume 30, Issue 9 (2022)
- Year:
- 2022
- Volume:
- 30
- Issue:
- 9
- Issue Sort Value:
- 2022-0030-0009-0000
- Page Start:
- 992
- Page End:
- 1000
- Publication Date:
- 2022-11
- Subjects:
- Patient prosthesis mismatch -- small aortic root -- aortic valve replacement
Heart -- Diseases -- Asia -- Periodicals
Heart -- Diseases -- Pacific Area -- Periodicals
Heart -- Diseases -- Periodicals
Heart -- Surgery -- Asia -- Periodicals
Heart -- Surgery -- Pacific Area -- Periodicals
Heart -- Surgery -- Periodicals
Chest -- Surgery -- Asia -- Periodicals
Chest -- Surgery -- Pacific Area -- Periodicals
Chest -- Surgery -- Periodicals
617.412 - Journal URLs:
- http://aan.sagepub.com ↗
http://asianannals.ctsnetjournals.org ↗
http://www.uk.sagepub.com ↗ - DOI:
- 10.1177/02184923221127661 ↗
- Languages:
- English
- ISSNs:
- 0218-4923
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23085.xml