A novel method for determining the X-ray beam angulation of the supraspinatus outlet view. (November 2022)
- Record Type:
- Journal Article
- Title:
- A novel method for determining the X-ray beam angulation of the supraspinatus outlet view. (November 2022)
- Main Title:
- A novel method for determining the X-ray beam angulation of the supraspinatus outlet view
- Authors:
- Zheng, Xiaoli
Hu, Jingying
Xu, Jian
Wang, Zhen
Shu, Zhenyu
Gong, Xiangyang - Abstract:
- Background: Rapid and accurate quantification of the supraspinatus outlet view (SOV) is a clinical challenge. Purpose: To quantify the X-ray beam angle of the SOV using the horizontal angle of the subscapular spine line (SSSL) and to further verify the feasibility of this method. Material and Methods: A total of 119 patients who underwent shoulder computed tomography (CT) examination were enrolled in the retrospective study. Three-dimensional (3D) CT reconstruction was performed and manually adjusted to provide the position similar to SOV. The rotation angle of the 3D image along the long axis of the human body (marked as β) was obtained. The horizontal angle of SSSL (marked as α) was measured on the anteroposterior localizer image of shoulder CT. Pearson correlation and linear regression correlation analysis were performed. In addition, the first-time success rate between the experience-based group and the measurement-based group were compared to verify the novel method. Results: We found a linear correlation between α and β (r = 0.962; P = 0.000). There was no significant correlation between the experience-based group and the measurement-based group in terms of age ( P = 0.500), sex ( P = 0.397), and side ( P = 0.710), but there was a significant statistical difference in the first success rate between the two validation groups (χ 2 = 5.808 a, P = 0.016). Conclusion: This novel quantitative measurement method for determining the X-ray beam angle of SOV using theBackground: Rapid and accurate quantification of the supraspinatus outlet view (SOV) is a clinical challenge. Purpose: To quantify the X-ray beam angle of the SOV using the horizontal angle of the subscapular spine line (SSSL) and to further verify the feasibility of this method. Material and Methods: A total of 119 patients who underwent shoulder computed tomography (CT) examination were enrolled in the retrospective study. Three-dimensional (3D) CT reconstruction was performed and manually adjusted to provide the position similar to SOV. The rotation angle of the 3D image along the long axis of the human body (marked as β) was obtained. The horizontal angle of SSSL (marked as α) was measured on the anteroposterior localizer image of shoulder CT. Pearson correlation and linear regression correlation analysis were performed. In addition, the first-time success rate between the experience-based group and the measurement-based group were compared to verify the novel method. Results: We found a linear correlation between α and β (r = 0.962; P = 0.000). There was no significant correlation between the experience-based group and the measurement-based group in terms of age ( P = 0.500), sex ( P = 0.397), and side ( P = 0.710), but there was a significant statistical difference in the first success rate between the two validation groups (χ 2 = 5.808 a, P = 0.016). Conclusion: This novel quantitative measurement method for determining the X-ray beam angle of SOV using the horizontal angle of SSSL is feasible. … (more)
- Is Part Of:
- Acta radiologica. Volume 63:Number 11(2022)
- Journal:
- Acta radiologica
- Issue:
- Volume 63:Number 11(2022)
- Issue Display:
- Volume 63, Issue 11 (2022)
- Year:
- 2022
- Volume:
- 63
- Issue:
- 11
- Issue Sort Value:
- 2022-0063-0011-0000
- Page Start:
- 1497
- Page End:
- 1503
- Publication Date:
- 2022-11
- Subjects:
- Supraspinatus outlet view -- 3D CT reconstruction -- X-ray beam angle
Radiology, Medical -- Periodicals
Radiography, Medical -- Periodicals
Radiotherapy -- Periodicals
616.0757 - Journal URLs:
- http://acr.sagepub.com ↗
http://ar.rsmjournals.com ↗
http://www.uk.sagepub.com/home.nav ↗
http://informahealthcare.com/loi/ard ↗
http://www.tandf.co.uk/journals/titles/02841851.asp ↗ - DOI:
- 10.1177/02841851211043835 ↗
- Languages:
- English
- ISSNs:
- 0284-1851
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0662.000000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23086.xml