Tunneled hemodialysis catheter insertion: Above, within, or below the right atrium—Where is the tip?. (25th September 2022)
- Record Type:
- Journal Article
- Title:
- Tunneled hemodialysis catheter insertion: Above, within, or below the right atrium—Where is the tip?. (25th September 2022)
- Main Title:
- Tunneled hemodialysis catheter insertion: Above, within, or below the right atrium—Where is the tip?
- Authors:
- Auer, Jonas
Braun, Joachim
Lenk, Julian
Gollrad, Johannes
Ro, Sa-Ra
Hamm, Bernd
de Bucourt, Maximilian - Abstract:
- Background: One major challenge when inserting a tunneled, cuffed central venous catheter (CVC) for hemodialysis under fluoroscopy is to accurately place the catheter tip by assessing its position in relation to the cardiac silhouette to approximate the right atrium (RA). Purpose: To investigate whether a weighted mean calculated from published results for two two-dimensional landmark reference distances may be useful in assessing CVC tip positions in relation to the RA. Material and Methods: Central venous catheter tip positions attained under fluoroscopic imaging during insertion using the cardiac silhouette as approximation were retrospectively related to two reference distances (carina to cranial RA border and craniocaudal RA extent), which were used to group catheter tip locations above (1), within (2), or below (3) the RA (henceforth referred to as landmark technique approximation, LTA). The LTA-derived catheter tip locations were validated by correlation with postinterventional computed tomography (CT) datasets acquired shortly after implantation (if available). Results: Based on LTA, 45 catheter tips (10.6%) were above, 179 (42.2%) within, and 200 (47.2%) below the RA. Postinterventional CT ( n = 57; 13.4%) visualized 26.3% above, 66.7% within, and 7.0% below the RA. Conclusion: The LTA reference distances appear to lead to a rather low categorization of the CVC tips, or the tips have been placed rather low in the study population. Validation using postinterventionalBackground: One major challenge when inserting a tunneled, cuffed central venous catheter (CVC) for hemodialysis under fluoroscopy is to accurately place the catheter tip by assessing its position in relation to the cardiac silhouette to approximate the right atrium (RA). Purpose: To investigate whether a weighted mean calculated from published results for two two-dimensional landmark reference distances may be useful in assessing CVC tip positions in relation to the RA. Material and Methods: Central venous catheter tip positions attained under fluoroscopic imaging during insertion using the cardiac silhouette as approximation were retrospectively related to two reference distances (carina to cranial RA border and craniocaudal RA extent), which were used to group catheter tip locations above (1), within (2), or below (3) the RA (henceforth referred to as landmark technique approximation, LTA). The LTA-derived catheter tip locations were validated by correlation with postinterventional computed tomography (CT) datasets acquired shortly after implantation (if available). Results: Based on LTA, 45 catheter tips (10.6%) were above, 179 (42.2%) within, and 200 (47.2%) below the RA. Postinterventional CT ( n = 57; 13.4%) visualized 26.3% above, 66.7% within, and 7.0% below the RA. Conclusion: The LTA reference distances appear to lead to a rather low categorization of the CVC tips, or the tips have been placed rather low in the study population. Validation using postinterventional CT indicated an underestimation of the RA in the LTA. Patient characteristics with a higher risk of false estimation through LTA have been defined. … (more)
- Is Part Of:
- Acta radiologica open. Volume 11:Number 9(2022)
- Journal:
- Acta radiologica open
- Issue:
- Volume 11:Number 9(2022)
- Issue Display:
- Volume 11, Issue 9 (2022)
- Year:
- 2022
- Volume:
- 11
- Issue:
- 9
- Issue Sort Value:
- 2022-0011-0009-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-09-25
- Subjects:
- Interventional -- heart -- catheters -- fluoroscopy -- computed tomography
Radiology -- Periodicals
Diagnostic Imaging -- Periodicals
Radiology
Periodicals
616.075705 - Journal URLs:
- http://arr.sagepub.com/ ↗
http://arr.sagepub.com/ ↗
http://www.uk.sagepub.com ↗
http://www.ncbi.nlm.nih.gov/pmc/journals/2704/ ↗ - DOI:
- 10.1177/20584601221122421 ↗
- Languages:
- English
- ISSNs:
- 2058-4601
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23080.xml