Projected network performance for multiple isotopes using next-generation xenon monitoring systems. (October 2022)
- Record Type:
- Journal Article
- Title:
- Projected network performance for multiple isotopes using next-generation xenon monitoring systems. (October 2022)
- Main Title:
- Projected network performance for multiple isotopes using next-generation xenon monitoring systems
- Authors:
- Eslinger, Paul W.
Ely, James H.
Lowrey, Justin D.
Miley, Harry S. - Abstract:
- Abstract: Since about 2000 (Bowyer et al., 1998), radioxenon monitoring systems have been under development and testing for the verification of the Comprehensive Nuclear Test-Ban Treaty (CTBT). Operation of the systems since then has resulted in development of a next-generation of systems that are nearly ready for operational deployment. By 2010, the need to screen out civilian sources was well known (Auer et al., 2010; Saey, 2009), and isotopic ratio approaches were soon considered (Kalinowski and Pistner, 2006) to identify specific sources. New generation systems are expected to improve the ability to verify the absence of nuclear tests by using isotopic ratios when multiple isotopes are detected. In this work, thousands of releases were simulated to compute the global detection probability of 131m Xe, 133m Xe, 133 Xe, and 135 Xe at 39 noble gas systems in the International Monitoring System (IMS) for both current and next-generation systems. Three release scenarios are defined at 1 h, 1 d, and 10 d past a 1 kt TNT equivalent 235 U explosion event. Multiple cases using from one part in a million to the complete release of the xenon isotopic activity are evaluated for each scenario. Coverage maps and global integrals comparing current and next-generation monitoring systems are presented showing that next-generation noble gas systems will create measurable improvements in the IMS. The global detection probability for 133 Xe is shown to be strong in all scenarios, but onlyAbstract: Since about 2000 (Bowyer et al., 1998), radioxenon monitoring systems have been under development and testing for the verification of the Comprehensive Nuclear Test-Ban Treaty (CTBT). Operation of the systems since then has resulted in development of a next-generation of systems that are nearly ready for operational deployment. By 2010, the need to screen out civilian sources was well known (Auer et al., 2010; Saey, 2009), and isotopic ratio approaches were soon considered (Kalinowski and Pistner, 2006) to identify specific sources. New generation systems are expected to improve the ability to verify the absence of nuclear tests by using isotopic ratios when multiple isotopes are detected. In this work, thousands of releases were simulated to compute the global detection probability of 131m Xe, 133m Xe, 133 Xe, and 135 Xe at 39 noble gas systems in the International Monitoring System (IMS) for both current and next-generation systems. Three release scenarios are defined at 1 h, 1 d, and 10 d past a 1 kt TNT equivalent 235 U explosion event. Multiple cases using from one part in a million to the complete release of the xenon isotopic activity are evaluated for each scenario. Coverage maps and global integrals comparing current and next-generation monitoring systems are presented showing that next-generation noble gas systems will create measurable improvements in the IMS. The global detection probability for 133 Xe is shown to be strong in all scenarios, but only modestly improved by next-generation equipment. However, the detection probability for 131m Xe and 133m Xe increased to about 50% in different scenarios, providing a second detectable isotope for many events. As anticipated from shorter sampling intervals, the expected number of detecting samples roughly doubled and the expected number of detecting stations rose by approximately 50% for all release scenarios. Thus, it might be anticipated that future events would consist of multiple 133 Xe detections and one or more second isotope detections. Signals of this nature should increase detection confidence, tighten release location estimates, improve rejection of civilian signals, and lessen the impacts from individual systems being offline for maintenance or repair reasons. Highlights: Network performance is compared for existing and next-generation noble gas systems. Next-generation xenon detection systems have improved detection levels and shorter sample collection times. Improved detection sensitivity for 131m Xe and 133m Xe will improve source type screening. Detection confidence and source location determination are improved. … (more)
- Is Part Of:
- Journal of environmental radioactivity. Volume 251/52(2022)
- Journal:
- Journal of environmental radioactivity
- Issue:
- Volume 251/52(2022)
- Issue Display:
- Volume 251/52, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 251/52
- Issue:
- 2022
- Issue Sort Value:
- 2022-NaN-2022-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-10
- Subjects:
- nuclear explosion -- CTBT -- new-generation systems -- international noble gas experiment -- INGE
Radioactivity -- Periodicals
Radiation, Background -- Periodicals
Radioecology -- Periodicals
Radioactive pollution -- Periodicals
Environmental Pollutants -- Periodicals
Radioactive Pollutants -- Periodicals
Radioactivity -- Periodicals
Radioécologie -- Périodiques
Pollution radioactive -- Périodiques
Fond de rayonnement -- Périodiques
539.752 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0265931X ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jenvrad.2022.106963 ↗
- Languages:
- English
- ISSNs:
- 0265-931X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4979.392000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23079.xml