"Virtual stent" – clinical evaluation and user experience of on-the-fly stent simulation in treatment of cerebral aneurysms. Issue 5 (October 2022)
- Record Type:
- Journal Article
- Title:
- "Virtual stent" – clinical evaluation and user experience of on-the-fly stent simulation in treatment of cerebral aneurysms. Issue 5 (October 2022)
- Main Title:
- "Virtual stent" – clinical evaluation and user experience of on-the-fly stent simulation in treatment of cerebral aneurysms
- Authors:
- Luecking, Hannes
Birkhold, Annette
Hoelter, Philip
Lang, Stefan
Goelitz, Philipp
Schmidt, Manuel
Mrochen, Anne
Brandner, Sebastian
Doerfler, Arnd - Abstract:
- Background: Predicting final stent position can be challenging when treating cerebral aneurysms. Third-Party software proved helpful in selecting proper stents in treatment planning. Recent angiographic systems provide basic stent simulation capabilities integrated in the post-processing software to simulate stent position. Goal of this analysis was to evaluate the simulation process and correlation with definite stent position. Materials and Methods: Thirty-three datasets with fusiform (n = 10) and saccular (n = 23) aneurysms, treated with stent or flow-diverter, were processed. A "virtual stent" of the same (nominal) size was simulated and its position was compared to the treatment result. Simulated length was rated in five grades (too short, shorter, equal, longer, too long), with regard to side-branches, anchoring zone etc. Simulation quality (centerline recognition/adherence to vessel margins) was rated in three grades (no, minor or major corrections required). Results: Simulation was successful in 32/33 cases (97%), with one abortive attempt (3%). In 27/33 simulations (82%), there was no need for centerline refinement. Minor corrections were necessary in four and major corrections in two cases. Simulated nominal length was rated "equal" in 14/33 (42%) cases and "shorter" or "longer" – but within acceptable range – in each 9/33 (27%) cases. Conclusion: Basic stent simulation tools available with genuine angiographic workplace software can provide good simulationBackground: Predicting final stent position can be challenging when treating cerebral aneurysms. Third-Party software proved helpful in selecting proper stents in treatment planning. Recent angiographic systems provide basic stent simulation capabilities integrated in the post-processing software to simulate stent position. Goal of this analysis was to evaluate the simulation process and correlation with definite stent position. Materials and Methods: Thirty-three datasets with fusiform (n = 10) and saccular (n = 23) aneurysms, treated with stent or flow-diverter, were processed. A "virtual stent" of the same (nominal) size was simulated and its position was compared to the treatment result. Simulated length was rated in five grades (too short, shorter, equal, longer, too long), with regard to side-branches, anchoring zone etc. Simulation quality (centerline recognition/adherence to vessel margins) was rated in three grades (no, minor or major corrections required). Results: Simulation was successful in 32/33 cases (97%), with one abortive attempt (3%). In 27/33 simulations (82%), there was no need for centerline refinement. Minor corrections were necessary in four and major corrections in two cases. Simulated nominal length was rated "equal" in 14/33 (42%) cases and "shorter" or "longer" – but within acceptable range – in each 9/33 (27%) cases. Conclusion: Basic stent simulation tools available with genuine angiographic workplace software can provide good simulation capabilities without need for third-party equipment. They can facilitate treatment planning and help to avoid shortage of devices. Yet, lack of calculation of foreshortening in large vessel diameters leaves the user to rely on their experience to account for device-specific properties. … (more)
- Is Part Of:
- Interventional neuroradiology. Volume 28:Issue 5(2022)
- Journal:
- Interventional neuroradiology
- Issue:
- Volume 28:Issue 5(2022)
- Issue Display:
- Volume 28, Issue 5 (2022)
- Year:
- 2022
- Volume:
- 28
- Issue:
- 5
- Issue Sort Value:
- 2022-0028-0005-0000
- Page Start:
- 581
- Page End:
- 587
- Publication Date:
- 2022-10
- Subjects:
- stent simulation -- cerebral aneurysm -- virtual stent -- flat panel ct
Nervous system -- Interventional radiology -- Periodicals
Nervous system -- Radiography -- Periodicals
Nervous System Diseases -- Periodicals -- radiography
Neuroradiography -- Periodicals
Radiography, Interventional -- Periodicals
Nervous system -- Radiography
Periodicals
617.4805 - Journal URLs:
- http://ine.sagepub.com/ ↗
http://web.ebscohost.com ↗
http://www.ncbi.nlm.nih.gov/pmc/journals/1673/ ↗
http://www.uk.sagepub.com/home.nav ↗ - DOI:
- 10.1177/15910199211053131 ↗
- Languages:
- English
- ISSNs:
- 1591-0199
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23062.xml