Leadless transcatheter pacemaker: Indications, implantation technique and peri-procedural patient management in the Italian clinical practice. (15th October 2022)
- Record Type:
- Journal Article
- Title:
- Leadless transcatheter pacemaker: Indications, implantation technique and peri-procedural patient management in the Italian clinical practice. (15th October 2022)
- Main Title:
- Leadless transcatheter pacemaker: Indications, implantation technique and peri-procedural patient management in the Italian clinical practice
- Authors:
- Palmisano, Pietro
Iacopino, Saverio
De Vivo, Stefano
D'Agostino, Carlo
Tomasi, Luca
Startari, Umberto
Ziacchi, Matteo
Pisanò, Ennio Carmine Luigi
Santobuono, Vincenzo Ezio
Caccavo, Vincenzo Paolo
Sgarito, Giuseppe
Rillo, Mariano
Nicosia, Antonino
Zucchelli, Giulio - Abstract:
- Abstract: Background: Safety and efficacy of leadless pacemakers (L-PM) have been demonstrated in multiple clinical trials, but real-world data on patient selection, implantation technique, and peri-procedural patient management in a clinical practice setting are lacking. Methods: Consecutive patients undergoing L-PM implantation in 14 Italian centers were followed in a prospective, multicentre, observational project. Data on baseline patient characteristics, clinical indications, implantation procedure, and peri-procedural patient management were collected. The rate and nature of device-related complications were also recorded. Results: A total of 782 L-PM patients (68.4% male, 75.6 ± 12.4 years) were included in the analysis. The main patients-related reason leading to the choice of implanting a L-PM rather than a conventional PM was the high-risk of device infection (29.5% of cases). The implantation success rate was 99.2%. The median duration of the procedure was 46 min. In 90% of patients the device was implanted in the septum. Of patients on oral anticoagulant therapy (OAT) ( n = 498) the implantation procedure was performed without interrupting (17.5%) or transiently interrupting OAT without heparin bridging (60.6%). During a median follow-up of 20 months major device-related complications occurred in 7 patients (0.9%): vascular access-site complications in 3 patients, device malfunction in 2 patients, pericardial effusion/cardiac tamponade in one patient, deviceAbstract: Background: Safety and efficacy of leadless pacemakers (L-PM) have been demonstrated in multiple clinical trials, but real-world data on patient selection, implantation technique, and peri-procedural patient management in a clinical practice setting are lacking. Methods: Consecutive patients undergoing L-PM implantation in 14 Italian centers were followed in a prospective, multicentre, observational project. Data on baseline patient characteristics, clinical indications, implantation procedure, and peri-procedural patient management were collected. The rate and nature of device-related complications were also recorded. Results: A total of 782 L-PM patients (68.4% male, 75.6 ± 12.4 years) were included in the analysis. The main patients-related reason leading to the choice of implanting a L-PM rather than a conventional PM was the high-risk of device infection (29.5% of cases). The implantation success rate was 99.2%. The median duration of the procedure was 46 min. In 90% of patients the device was implanted in the septum. Of patients on oral anticoagulant therapy (OAT) ( n = 498) the implantation procedure was performed without interrupting (17.5%) or transiently interrupting OAT without heparin bridging (60.6%). During a median follow-up of 20 months major device-related complications occurred in 7 patients (0.9%): vascular access-site complications in 3 patients, device malfunction in 2 patients, pericardial effusion/cardiac tamponade in one patient, device migration in one patient. Conclusions: In the real world setting of Italian clinical practice L-PM is often reserved for patients at high-risk of infection. The implantation success rate was very high and the risk of major complications was low. Peri-procedural management of OAT was consistent with available scientific evidence. Highlights: Leadless pacemaker is often reserved for patients at high-risk of infection. Electrical parameters are optimal and remain stable during follow-up. The rate of major device-related complications is low. Peri-procedural management of OAT was consistent with available scientific evidence. … (more)
- Is Part Of:
- International journal of cardiology. Volume 365(2022)
- Journal:
- International journal of cardiology
- Issue:
- Volume 365(2022)
- Issue Display:
- Volume 365, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 365
- Issue:
- 2022
- Issue Sort Value:
- 2022-0365-2022-0000
- Page Start:
- 49
- Page End:
- 56
- Publication Date:
- 2022-10-15
- Subjects:
- Leadless pacemaker -- Transvenous pacemaker -- Complications -- Lead-related complications -- Pocket-related complications -- Device infection
Cardiology -- Periodicals
Electronic journals
616.12 - Journal URLs:
- http://www.clinicalkey.com/dura/browse/journalIssue/01675273 ↗
http://www.sciencedirect.com/science/journal/01675273 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ijcard.2022.07.040 ↗
- Languages:
- English
- ISSNs:
- 0167-5273
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.158000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23058.xml